GJL1313561R6002 ABB Control Contactors

ABB Control GJL1313561R6002 ABB GJL1313561R6002 is a magnetic mini contactor from the TBC7 contactors sub-range, designed with an expanded ambient temperature range of -30 to +70°C. It features screw-clamp connections and is equipped with 4 poles (2NO+2NC). The rated current varies with conditions: 20A at 380-400Vac and 40°C, 16A at 380-400Vac and 55°C, and 6A at both 690Vac at 40°C and 55°C, under AC-1 utilization category. The rated insulation voltage is 690 V according to IEC/VDE standards and 600 V according to UL/CSA standards. This contactor is designed for mounting on a plate, with dimensions of 46.5 mm in height, 52.5 mm in width, and 57.5 mm in depth. The control voltage for DC operations is specified at 77-143Vdc (110Vdc), with a current consumption of 3.5W for both inrush and holding states of the coil. The rated operating voltage (Ue) is 690 V, and it has no normally open (NO) or normally closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV. The operating rate varies by application, with 300 cycles/hour for AC-1, 600 cycles/hour for AC-3, 360 cycles/hour for AC-15, 600 cycles/hour for DC-1, 360 cycles/hour for DC-13, and 600 cycles/hour for DC-3.
ABB Control

Part#:GJL1313561R6002

Manufacturer:ABB Control

Product Lifecycle:Active

Get a quick Quote!

ABB GJL1313561R6002 is a magnetic mini contactor from the TBC7 contactors sub-range, designed with an expanded ambient temperature range of -30 to +70°C. It features screw-clamp connections and is equipped with 4 poles (2NO+2NC). The rated current varies with conditions: 20A at 380-400Vac and 40°C, 16A at 380-400Vac and 55°C, and 6A at both 690Vac at 40°C and 55°C, under AC-1 utilization category. The rated insulation voltage is 690 V according to IEC/VDE standards and 600 V according to UL/CSA standards. This contactor is designed for mounting on a plate, with dimensions of 46.5 mm in height, 52.5 mm in width, and 57.5 mm in depth. The control voltage for DC operations is specified at 77-143Vdc (110Vdc), with a current consumption of 3.5W for both inrush and holding states of the coil. The rated operating voltage (Ue) is 690 V, and it has no normally open (NO) or normally closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV. The operating rate varies by application, with 300 cycles/hour for AC-1, 600 cycles/hour for AC-3, 360 cycles/hour for AC-15, 600 cycles/hour for DC-1, 360 cycles/hour for DC-13, and 600 cycles/hour for DC-3.

About the manufacturer: ABB Control is one of the manufacturers that offers Contactors that you can order at marketplace.quotebeam.com. ABB's Industrial Automation division offers a variety of solutions designed for process and hybrid industries, including industry-specific integrated automation, electrification, and digital solutions, control technologies, software, and advanced services.

Check out the GJL1313561R6002 ABB Control price in the box on the right side or send a quick quote.

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


GJL1313561R6002 Description

ABB GJL1313561R6002 is a magnetic mini contactor from the TBC7 contactors sub-range, designed with an expanded ambient temperature range of -30 to +70°C. It features screw-clamp connections and is equipped with 4 poles (2NO+2NC). The rated current varies with conditions: 20A at 380-400Vac and 40°C, 16A at 380-400Vac and 55°C, and 6A at both 690Vac at 40°C and 55°C, under AC-1 utilization category. The rated insulation voltage is 690 V according to IEC/VDE standards and 600 V according to UL/CSA standards. This contactor is designed for mounting on a plate, with dimensions of 46.5 mm in height, 52.5 mm in width, and 57.5 mm in depth. The control voltage for DC operations is specified at 77-143Vdc (110Vdc), with a current consumption of 3.5W for both inrush and holding states of the coil. The rated operating voltage (Ue) is 690 V, and it has no normally open (NO) or normally closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV. The operating rate varies by application, with 300 cycles/hour for AC-1, 600 cycles/hour for AC-3, 360 cycles/hour for AC-15, 600 cycles/hour for DC-1, 360 cycles/hour for DC-13, and 600 cycles/hour for DC-3.


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of ABB Control

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

ABB Control Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many ABB Control Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from ABB Control, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

GJL1317201R0001 Part Image. Manufactured by ABB Control.

GJL1317201R0001

Verified stock: 0

ABB GJL1317201R0001 is a magnetic mini contactor from the B7D contactors sub-range, featuring screw-clamp connections and a 4-pole (4NO) configuration. It has a rated current of 20A at 380-400Vac (40°C; AC-1), 16A at 380-400Vac (55°C; AC-1), 6A at 690Vac (40°C; AC-1), 6A at 690Vac (55°C; AC-1), with AC-15 ratings of 4A at 24-120Vac, 4A at 220-240Vac, 3A at 380-400Vac, and 2A at 500Vac. UL/CSA FLA ratings include 13.8A at 115Vac (single-phase), 7.8A at 200Vac (3-phase), 9.6A at 220-240Vac (3-phase), 10A at 230Vac (single-phase), 7.6A at 440-480Vac (3-phase), and 6.1A at 550-600Vac (3-phase). The rated insulation voltage is 690 V (IEC/VDE) and 600 V (UL/CSA), with a mounting mode on plate. Dimensions are 57.5 mm in height, 52.5 mm in width, and 46.5 mm in depth. Control voltage is 24Vdc, with a current consumption of 3.5W for both inrush and holding (coil). Rated operating voltage (Ue) is 690 V, with 0 normally open (NO) auxiliary contacts, a rated impulse voltage (Uimp) of 6 kV, and no normally closed (NC) auxiliary contacts. Rated active power is 3kW at 220-240Vac (AC-3), 5.5kW at 380-440Vac (AC-3), 5.5kW at 500Vac (AC-3), and 3kW at 690Vac (AC-3). Rated power (HP) for UL/CSA is 3HP at 220-240Vac (3-phase), 5HP at 440-480Vac (3-phase), and 5HP at 550-600Vac (3-phase). Operating rates are 300 cycles/hour (AC-1), 600 cycles/hour (AC-3), 360 cycles/hour (AC-15), 600 cycles/hour (DC-1), 360 cycles/hour (DC-13), and 600 cycles/hour (DC-3).

ABB Control

GJL1311201R8005 Part Image. Manufactured by ABB Control.

GJL1311201R8005

Verified stock: 0

ABB GJL1311201R8005 is a magnetic mini contactor from the B7 contactors sub-range, featuring screw-clamp connections and a 4-pole (4NO) configuration. It has a rated current of 20A at 380-400Vac (40°C; AC-1), 16A at 380-400Vac (55°C; AC-1), 6A at 690Vac (40°C; AC-1), 6A at 690Vac (55°C; AC-1), 4A at 24-120Vac (AC-15), 4A at 220-240Vac (AC-15), 3A at 380-400Vac (AC-15), and 2A at 500Vac (AC-15). For UL/CSA FLA, it supports 13.8A at 115Vac (single-phase), 7.8A at 200Vac (3-phase), 9.6A at 220-240Vac (3-phase), 10A at 230Vac (single-phase), 7.6A at 440-480Vac (3-phase), and 6.1A at 550-600Vac (3-phase). The rated insulation voltage is 690 V (IEC/VDE) and 600 V (UL/CSA), with a mounting mode on the plate. Its dimensions are 57.5 mm in height, 52.5 mm in width, and 46.5 mm in depth. The current consumption is 3.5VA inrush and holding (coil), with a control voltage of 380Vac-415Vac (400Vac) (40Hz-450Hz). The rated operating voltage (Ue) is 690 V, with 0 normally open (NO) auxiliary contacts, a rated impulse voltage (Uimp) of 6 kV, and rated active power of 3kW at 220-240Vac (AC-3), 5.5kW at 380-440Vac (AC-3), 5.5kW at 500Vac (AC-3), and 3kW at 690Vac (AC-3). It has 0 normally closed (NC) auxiliary contacts, with a rated power of 3HP at 220-240Vac (3-phase; UL/CSA), 5HP at 440-480Vac (3-phase; UL/CSA), and 5HP at 550Vac-600Vac (3-phase; UL/CSA). The operating rate is 300 cycles/hour (AC-1), 600 cycles/hour (AC-3), 360 cycles/hour (AC-15), 600 cycles/hour (DC-1), 360 cycles/hour (DC-13), and 600 cycles/hour (DC-3).

ABB Control

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo