Festo 5340824 servo drive CMMT-AS-C2-3A-EP-S1 Mounting type: Mounting plate, bolted, Assembly position: (* Free convection, * Vertical), Product weight: 1300 g, Display: LED green/yellow/red, Control elements: Optional: control unit CDSB
Festo

Part#:5340824

Manufacturer:Festo

Alt. Part#:CMMT-AS-C2-3A-EP-S1

Product Lifecycle:Active

Get a quick Quote!

servo drive CMMT-AS-C2-3A-EP-S1 Mounting type: Mounting plate, bolted, Assembly position: (* Free convection, * Vertical), Product weight: 1300 g, Display: LED green/yellow/red, Control elements: Optional: control unit CDSB

About the manufacturer: Festo is one of the manufacturers that offers Servo Amplifiers that you can order at marketplace.quotebeam.com. Festo Corp. has been a top supplier of automation and intelligent automation solutions for more than four decades in the United States and eight decades globally. The company is committed to transforming the manufacturing sector and enhancing business efficiency.

Check out the 5340824 Festo price in the box on the right side or send a quick quote.

Product Details

  • Protection class
    I
  • Number of high-speed switching outputs
    2
  • Max. continuous output of the external braking resistor (IEC)
    180 W
  • Pulse energy for braking resistor
    230 Ws
  • Max. short circuit protection of mains
    100 kA
  • Fieldbus interface, function
    Bus connection, incoming/forwarding EtherNet/IP slave
  • Information on max. installation height
    1% power reduction/100 m above 1000 m.
  • Mains types
    TT IT
  • Fieldbus interface, protocol
    EtherNet/IP
  • Number of floating switching outputs
    1
  • Max. current of the floating switching outputs
    50 mA
  • Max. output current of holding brake
    1 A
  • Max. current consumption for logic supply with parking brake
    1.5 A
  • Based on norm
    EN 50581 EN 62061
  • Active PFC
    no
  • Control elements
    Optional: CDSB operating unit
  • Impedance of setpoint input
    70 kOhm
  • Max. DC link voltage
    395 V
  • Nominal voltage, logic supply DC
    24 V
  • Nominal voltage, load supply DC
    320 V
  • Peak current per phase, effective
    6 A
  • Permissible range of logic voltage
    ± 20 %
  • Degree of protection
    IP20
  • Certification
    RCM compliance mark c UL us - Listed (OL)
  • Communication profile
    DriveProfile
  • Work range of setpoint input
    ± 10 V
  • Note on materials
    Contains paint-wetting impairment substances RoHS-compliant
  • Mounting position
    Free convection Vertical
  • Ethernet interface, protocol
    TCP/IP
  • Fieldbus interface, connection technology
    RJ45
  • Encoder interface 2, function
    Incremental encoder SIN/COS encoder
  • Number of diagnostic outputs
    2
  • Max. voltage drop from logic supply to brake output
    0.8 V
  • Number of safe 2-pin inputs
    2
  • Time resolution of high-speed switching outputs
    1 µs
  • Safety function
    Safe brake control (SBC) Safe stop 1 (SS1)
  • Output voltage range AC
    3x (0 – input) V
  • Characteristics of digital logic outputs
    Freely configurable in some cases Diagnostic outputs in some cases
  • Hardware fault tolerance
    1
  • Nominal current load supply
    2.8 A
  • Peak current, load supply
    8.4 A
  • Permissible voltage fluctuations
    -20 % / +15 %
  • Relative air humidity
    5 - 90 % Non-condensing
  • Product weight
    1300 g
  • Encoder interface output, characteristics
    1 MHz maximum output frequency max. 16384 ppr
  • Operating range of analog inputs
    ± 10 V
  • Switching logic at outputs
    PNP (positive switching)
  • Type code
    CMMT-AS
  • KC characters
    KC EMC
  • Encoder interface, function
    EnDat® 2.1 encoder SIN/COS encoder
  • Synchronization interface, function
    Encoder emulation A/B/Z Encoder input A/B/Z
  • Number of inputs for motor temperature sensor
    1
  • System voltage to EN 61800-5-1
    300 V
  • Conforms to standard
    EN 61800-3 EN ISO 13849-1
  • Line filter
    Integrated
  • Display
    LED green/yellow/red
  • Pulse power of braking resistor
    1.6 kVA
  • Max. peak current duration
    2 s
  • Input voltage range AC
    100 V ... 230 V
  • Nominal current per phase, effective
    2 A
  • SFF safe failure fraction
    99 %
  • Max. current consumption for logic supply without clamping brake
    0.5 A
  • Contamination level
    2
  • Certificate issuing authority
    German Technical Control Board (TÜV) Rheinland 01/205/5640.00/18 UL E331130
  • Note on ambient temperature
    Above an ambient temperature of 40 °C, the power must be reduced by 3%/°C.
  • Number of digital logic inputs
    12
  • Process interfacing
    Adjustable-Speed Drives Drives with positioning function
  • Input switching logic
    PNP (positive switching)
  • Type of mounting
    Mounting plate, screwed on
  • Fieldbus interface, transmission rate
    100 Mbit/s
  • Ethernet interface, function
    Parameterization and commissioning
  • Overvoltage category
    III
  • Fieldbus interface, connection type
    2x socket
  • Number of high-speed logic inputs
    2
  • Braking resistor nominal power (IEC)
    23 W
  • Time resolution of high-speed logic inputs
    1 µs
  • Controller operating mode
    Cascade control Autotuning
  • Performance Level (PL)
    Safe brake control (SBC)/category 3, performance level e Safe torque off (STO)/category 4, performance level e
  • Output frequency
    0 Hz ... 599 Hz
  • Diagnostic coverage
    97 %
  • Max. length of motor cable without ext. mains filter
    25 m
  • Nominal operating voltage AC
    230 V
  • Mains frequency
    48 Hz ... 62 Hz
  • Peak power
    1000 VA
  • Surge resistance
    6 kV
  • Max. current consumption for logic supply with clamping brake and I/O
    2.3 A
  • Ambient temperature
    0 °C ... 50 °C
  • UL-ambient temperature
    0 °C ... 40 °C
  • Number of digital logic outputs 24 V DC
    6
  • Logic input specification
    Based on IEC 61131-2, type 3
  • Encoder interface input, characteristics
    1 MHz maximum output frequency max. 16384 ppr
  • Characteristics of setpoint inputs
    Differential inputs Configurable for current/force
  • Max. installation height
    2000 m
  • Mode of operation
    Field-oriented regulation 1x SYNC interface for encoder emulation or encoder input
  • Safety integrity level (SIL)
    Safe brake control (SBC)/SIL 3/SILCL 3 Safe torque off (STO)/SIL 3/SILCL 3
  • Braking resistor, external
    100 Ohm ... 160 Ohm
  • Braking resistor, integrated
    100 Ohm
  • Max. current of digital logic outputs
    20 mA
  • Controller nominal power
    350 VA
  • Nominal operating voltage phases
    1-phase
  • Load supply permissible range
    -20 %/+15 %
  • CE marking (see declaration of conformity)
    As per EU EMC directive As per EU RoHS directive
  • Storage temperature
    -25 °C ... 55 °C
  • Number of analog setpoint inputs
    1
  • Work range of logic input
    -3 V ... 30 V
  • Characteristics of logic input
    Freely configurable in some cases Not galvanically isolated
  • Fieldbus coupling
    EtherNet/IP

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



Related documents 5340824 Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Festo

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Festo Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Festo Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Festo, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo