Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

8036877 Festo Flow Sensors

Festo 8036877 flow sensor SFAW-100-TG1-E-PNLK-PNVBA-M12 For measuring and monitoring flow rate, volume and temperature of liquid media, flow measuring range 100l/min. Authorisation: (* RCM Mark, * c UL us - Listed (OL)), CE mark (see declaration of conformity): (* to E
Festo

Part#:8036877

Manufacturer:Festo

Alt. Part#:SFAW-100-TG1-E-PNLK-PNVBA-M12

Product Lifecycle:Active

Get a quick Quote!

flow sensor SFAW-100-TG1-E-PNLK-PNVBA-M12 For measuring and monitoring flow rate, volume and temperature of liquid media, flow measuring range 100l/min. Authorisation: (* RCM Mark, * c UL us - Listed (OL)), CE mark (see declaration of conformity): (* to E

About the manufacturer: Festo is one of the manufacturers that offers Flow Sensors that you can order at marketplace.quotebeam.com. Festo Corp. has been a top supplier of automation and intelligent automation solutions for more than four decades in the United States and eight decades globally. The company is committed to transforming the manufacturing sector and enhancing business efficiency.

Check out the 8036877 Festo price in the box on the right side or send a quick quote.

Product Details

  • Nominal temperature
    23 °C
  • Temperature co-efficient margin in ± %FS/K
    Typ. ±0.05% FS/K
  • Max. load resistance of current output
    500 Ohm
  • Short-circuit protection
    yes
  • IO-Link®, communication mode
    COM2 (38,4 kBd)
  • IO-Link®, port class
    A
  • Reverse polarity protection
    for all electrical connections
  • Product weight
    400 g
  • Degree of protection
    IP65
  • Symbol
    00995566
  • Flow direction
    Unidirectional P1 -> P2
  • Operating medium
    Liquid media Neutral liquids
  • Temperature of medium
    0 °C ... 90 °C
  • Accuracy of flow rate
    ±2 % FS for flow rate <= 50 % FS ±3 % o.m.v. for flow rate >= 50 %FS
  • Switching element function
    N/C contact/N/O contact switchable
  • Min. load resistance of voltage output
    15 kOhm
  • IO-Link®, protocol version
    Device V 1.1
  • IO-Link®, process data width IN
    3 Byte
  • IO-Link®, data memory required
    500 byte
  • Electrical connection
    5-pin Plug, straight
  • Housing material
    PA-reinforced
  • KC characters
    KC EMC
  • CE marking (see declaration of conformity)
    As per EU EMC directive As per EU RoHS directive
  • Method of measurement
    Flow rate: vortex Temperature: PT1000
  • Operating pressure
    0 bar ... 12 bar
  • Information on operating and pilot media
    Media with a kinematic viscosity = 1.8 mm²/sec. [cSt]. Compatibility of the media with the substances that come into contact with the media must be ensured.
  • Repetition accuracy of flow rate value
    < ±0.5 % FS for flow rate <= 50 % FS < ±1 % o.m.v. for flow rate >= 50 %FS
  • Max. output current
    100 mA
  • Overload protection
    Available
  • IO-Link®, profile
    Smart sensor profile
  • IO-Link®, service data contents IN
    32 bit volume measurement
  • Fluid connector
    Internal thread G1
  • Displayable unit(s)
    US gal °F
  • Certification
    RCM compliance mark c UL us - Listed (OL)
  • Note on materials
    RoHS-compliant
  • Flow measuring range start value
    5 l/min
  • Information on operating pressure
    Max. 12 bar at 40°C Max. 6 bar at 100 °C
  • Switching output
    2 x PNP or 2 x NPN switchable
  • Switching function
    Window comparator Freely programmable
  • Flow characteristic curve, end value
    100 l/min
  • IO-Link®, function classes
    Binary data channel (BDC) Teach channel
  • IO-Link®, SIO mode support
    Yes
  • IO-Link®, minimum cycle time
    5 ms
  • DC operating voltage range
    18 V ... 30 V
  • Corrosion resistance class (CRC)
    3 - High corrosion stress
  • Type code
    SFAW
  • Measured variable
    Flow rate Temperature
  • Flow measuring range end value
    100 l/min
  • Ambient temperature
    0 °C ... 50 °C
  • Accuracy of temperature in ± °C
    2 °C
  • Analog output
    0 - 10 V 1 - 5 V
  • Flow characteristic curve, start value
    0 l/min
  • Protocol
    IO-Link®
  • IO-Link®, process data width OUT
    0 Byte
  • IO-Link®, process data content IN
    1 bit BDC (volume monitoring) 2 bit BDC (flow monitoring)
  • Max. cable length
    20 m for IO-Link® operation 30 m
  • Mounting position
    Any
  • Materials in contact with the media
    EPDM (peroxide) PA6T/6I-reinforced

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



Related documents 8036877 Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Festo

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Festo Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Festo Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Festo, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo