  • Fe360 steel
    1
  • Brass
    0.33
  • Customs tariff number
    85365019
  • Copper
    0.24
  • Protection class
    II
  • Test procedure for EMC in accordance with standard
    IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4
  • Aluminum
    0.26
  • Standards applied
    IEC 60947-5-2
  • Stainless steel
    0.71
  • Approvals
    c UL US
  • Degree of protection
    IP 68; IP 69K
  • Ambient temperature, storage
    -25 ... 85 °C
  • Ambient temperature, operation
    -25 ... 85 °C
  • Standard measuring plate
    90 x 90 mm², Fe360
  • Type of fastening
    Through-hole mounting
  • Housing color
    Black; Red, RAL 3000
  • Number of LEDs
    4 Piece(s)
  • Sensing face material
    Plastic, Polyamide (PA 66)
  • Net weight
    127 g
  • Type of display
    LED
  • Plastic housing
    PA 66
  • Type of installation
    Non-embedded
  • Housing material
    Plastic
  • Dimension (W x H x L)
    40 mm x 40 mm x 67 mm
  • Encoding
    A-coded
  • No. of pins
    4 -pin
  • Material
    Metal
  • Design
    Cubic
  • Type
    Male
  • Type of connection
    Connector
  • Function
    Signal OUT; Voltage supply
  • Thread size
    M12
  • Number of connections
    1 Piece(s)
  • Readiness delay
    100 ms
  • Switching frequency
    100 Hz
  • Switching principle
    NO contact – Antivalent
  • Switching element
    Transistor, PNP
  • Repeatability, max. (in % of Sr)
    10 %, For UB = 20 … 30 V DC, ambient temperature Ta = 23 °C ± 5 °C
  • Switching hysteresis
    15 %
  • Voltage drop
    ≤ 2 V
  • Residual current, max.
    0.01 mA
  • Number of digital switching outputs
    2 Piece(s)
  • Voltage type
    DC
  • Switching current, max.
    200 mA
  • Temperature drift, max. (in % of Sr)
    10 %, Over the entire operating temperature range
  • Residual ripple
    0 ... 20 %, From UB
  • Open-circuit current
    0 ... 30 mA
  • Supply voltage UB
    10 ... 30 V, DC
  • Series
    244
  • type. operating range limit Sn
    30 mm
  • Protective circuit
    Inductive protection; Polarity reversal protection; Short circuit protected
  • Special version
    Antivalent
  • Operating range Sa
    0 ... 24.3 mm

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


ISS 244PP.1/44-30N-S12 Description

ISS 244PP.1/44-30N-S12 Leuze - Inductive switch



Related documents ISS 244PP.1/44-30N-S12 Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Leuze

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Leuze Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Leuze Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Leuze, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo