Product Details

  • Customs tariff number
    85365019
  • Fe360 steel
    1
  • Brass
    0.25
  • Standards applied
    IEC 60947-5-2
  • Test procedure for EMC in accordance with standard
    IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4
  • Protection class
    II
  • Stainless steel
    0.85
  • Aluminum
    0.2
  • Copper
    0.1
  • Approvals
    c UL US
  • Ambient temperature, operation
    -25 ... 85 °C
  • Degree of protection
    IP 68; IP 69K
  • Ambient temperature, storage
    -25 ... 85 °C
  • Net weight
    130 g
  • Standard measuring plate
    120 x 120 mm², Fe360
  • Housing color
    Black; Red, RAL 3000
  • Number of LEDs
    4 Piece(s)
  • Sensing face material
    Plastic, Polyamide (PA 66)
  • Type of display
    LED
  • Type of fastening
    Through-hole mounting
  • Type of installation
    Non-embedded
  • Plastic housing
    PA 66
  • Dimension (W x H x L)
    40 mm x 40 mm x 67 mm
  • Housing material
    Plastic
  • Type
    Male
  • Encoding
    A-coded
  • No. of pins
    4 -pin
  • Design
    Cubic
  • Thread size
    M12
  • Material
    Metal
  • Type of connection
    Connector
  • Function
    Signal OUT; Voltage supply
  • Number of connections
    1 Piece(s)
  • Switching frequency
    100 Hz
  • Readiness delay
    100 ms
  • Switching element
    Transistor, PNP
  • Switching current, max.
    200 mA
  • Switching principle
    NO contact – Antivalent
  • Residual current, max.
    0.01 mA
  • Voltage type
    DC
  • Voltage drop
    ≤ 2 V
  • Number of digital switching outputs
    2 Piece(s)
  • Switching hysteresis
    15 %
  • Repeatability, max. (in % of Sr)
    10 %, For UB = 20 … 30 V DC, ambient temperature Ta = 23 °C ± 5 °C
  • Special version
    Antivalent
  • Temperature drift, max. (in % of Sr)
    10 %, Over the entire operating temperature range
  • Open-circuit current
    0 ... 30 mA
  • Series
    244
  • Protective circuit
    Inductive protection; Polarity reversal protection; Short circuit protected
  • type. operating range limit Sn
    40 mm
  • Operating range Sa
    0 ... 32.4 mm
  • Supply voltage UB
    10 ... 30 V, DC
  • Residual ripple
    0 ... 20 %, From UB

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


ISS 244PP.1/44-40N-S12 Description

ISS 244PP.1/44-40N-S12 Leuze - Inductive switch



Related documents ISS 244PP.1/44-40N-S12 Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Leuze

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Leuze Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Leuze Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Leuze, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo