L250-P41SL-M12B8-PB-UCA Leuze Safety Switch Interlocks
Part#:L250-P41SL-M12B8-PB-UCA
Manufacturer:Leuze
Alt. Part#:50142124
Product Lifecycle:Active
Get a quick Quote!
L250-P41SL-M12B8-PB-UCA Leuze - Safety locking device
Check out the L250-P41SL-M12B8-PB-UCA Leuze price in the box on the right side or send a quick quote.
Product Details
- Customs tariff number 85369095
- Ambient temperature, operation -20 ... 50 °C
- Approvals ECOLAB; TÜV Süd; c UL US
- Degree of protection IP 67; IP 69K
- Ambient temperature, storage -40 ... 75 °C
- Number of LEDs 5 Piece(s)
- Nominal switching distance Sn 3 mm
- Assured cut-out distance Sar 6 mm (actuator not locked); 10 mm (actuator locked)
- Extraction force, unlocked actuator 20 N
- Type of display LED
- Actuation frequency, max. 600 per hour, IEC 60947-5-1
- Assured operating distance Sao 2 mm
- Max. switching frequency 1 Hz
- Repeatability ≤ 10 % Sn
- Differential travel ≤ 20 % Sn
- Mechanical life time 1,000,000 actuation cycles, IEC 60947-5-1
- Release device Auxiliary release; Escape release button
- Locking force, max. 2,100 N
- Approach speed 0.001 ... 0.5 m/s
- Switch type Interlock device with guard interlocking
- Locking type Spring force
- Locking actuation Spring
- Type of fastening Through-hole mounting
- Side of cable entry From below
- Housing color Gray
- Net weight 500 g
- Housing material Plastic
- Dimension (W x H x L) 40 mm x 191.2 mm x 79.3 mm
- Design Cubic
- Material Metal
- No. of pins 8 -pin
- Encoding A-coded
- Type of connection Connector
- Thread size M12
- Number of safety-related switching outputs (OSSDs) 2 Piece(s)
- Switching element Transistor, PNP
- Current consumption, type. 5 mA
- Function IE1 activation input: electromagnet
- Number of connections 1 Piece(s)
- Number of digital switching outputs 1 Piece(s)
- Voltage type DC
- Teach input for actuator Yes
- Switching voltage, type. 24 V
- Type Digital switching input
- Encoding level High, EN ISO 14119
- Category 4, EN ISO 13849
- External safeguarding for supply circuit 2A type Gg (or equivalent)
- Current consumption, max. 1,200 mA
- Mission time 20 years, EN ISO 13849-1
- Type of wiring Single connection
- Supply voltage UB 24 V, DC, -10 ... 10 %
- Number of digital switching inputs 3 Piece(s)
- DC High
- Performance Level (PL) Up to and including e, EN ISO 13849-1
- Operating principle Quiescent current principle – Actuator locked if electromagnet is deactivated
- PFHD 1.23E-09 per hour
- MTTFd 2,254 years, EN ISO 13849-1
- SIL 3, IEC 61508
- Activation mode of safety outputs Safety outputs active if safety door is closed and locked
- Series L250
- SILCL 3, IEC/EN 62061
- Functions Locking device with guard interlocking in acc. with EN ISO 14119 (type 4)
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
L250-P41SL-M12B8-PB-UCA Description
L250-P41SL-M12B8-PB-UCA Leuze - Safety locking device
Related documents L250-P41SL-M12B8-PB-UCA Specs
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Leuze
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Leuze Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Leuze Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Leuze, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨