  • Customs tariff number
    85369095
  • Ambient temperature, storage
    -40 ... 70 °C
  • Test procedure for shock in accordance with standard
    IEC/EN 60068-2-6
  • US patents
    US 6,418,546 B
  • Shock resistance
    100 m/s²
  • Protection class
    III
  • Approvals
    TÜV Süd; c UL US
  • Test procedure for oscillation in accordance with standard
    IEC/EN 60068-2-6
  • Degree of protection
    IP 67
  • Ambient temperature, operation
    -30 ... 60 °C
  • Relative humidity (non-condensing)
    0 ... 95 %
  • Dimension (W x H x L)
    60 mm x 38.3 mm x 225 mm
  • Net weight
    560 g
  • Housing color
    Yellow
  • Type of display
    LED
  • Function of the operational control
    Selection of operating mode
  • Type of fastening
    Mounting plate; Mounting plate with L-angle; Through-hole mounting
  • Number of LEDs
    14 Piece(s)
  • Operational controls
    DIP switch
  • Permissible conductor cross section, type.
    0.25 mm²
  • Connector type
    USB 2.0 Micro-B
  • Length of connection cable, max.
    50 m
  • Restart delay time
    100 ms
  • Thread size
    M12
  • No. of pins
    8 -pin
  • Material
    Metal
  • Number of connections
    8 Piece(s)
  • Regression delay
    5 ms
  • Residual current, type.
    0.002 mA
  • Load capacity
    0.3 µF
  • Switching element
    Transistor, PNP
  • Residual current, max.
    0.2 mA
  • Type of connection
    Connector
  • Load inductivity
    2,000 µH
  • Number of digital switching outputs
    3 Piece(s)
  • Voltage type
    DC
  • Switching voltage, type.
    24 V
  • Function
    Control input, reset of the control; Control input for Reset
  • Switching current, max.
    380 mA
  • Type
    Digital switching input
  • Switching voltage high, min.
    27 V
  • Number of safety-related switching outputs (OSSDs)
    2 Piece(s)
  • Number of safety-related switching inputs
    2 Piece(s)
  • Switching voltage low, max.
    2.5 V
  • Power consumption, max.
    3.6 W, For 24 V, plus output load
  • Current consumption, max.
    150 mA, Without external load
  • Supply voltage UB
    24 V, DC, -20 ... 20 %, Compensation necessary at 20 ms voltage dip, min. 250 mA (+ external loads)
  • Category
    4, EN ISO 13849-1
  • Number of digital switching inputs
    8 Piece(s)
  • Residual ripple
    -5 ... 5 %, From UB
  • Application
    Muting interface for muting applications in combination with standard variants of the MLC and ELC safety light curtains, as well as MLD multiple light beam safety devices
  • Restart
    Automatic; Manual
  • Protective circuit
    Overvoltage protection; Polarity reversal protection; Short circuit protected
  • Performance Level (PL)
    e, EN ISO 13849-1
  • SIL
    3, IEC 61508
  • Functions
    Muting-timeout extension; Muting enable function; Timing controlled 2-sensor muting
  • Mission time
    20 years, EN ISO 13849-1
  • Series
    MSI-MD-FB
  • SILCL
    3, IEC/EN 62061
  • PFHD
    2.5E-09 per hour

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


MSI-MD-FBX Description

MSI-MD-FBX Leuze - Muting interface


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Leuze

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Leuze Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Leuze Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Leuze, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo