RSL445-XL/CU429-25 Leuze Safety Laser Scanners
Part#:RSL445-XL/CU429-25
Manufacturer:Leuze
Alt. Part#:53800294
Product Lifecycle:Active
Get a quick Quote!
RSL445-XL/CU429-25 Leuze - Safety laser scanner
Check out the RSL445-XL/CU429-25 Leuze price in the box on the right side or send a quick quote.
Product Details
- Customs tariff number 85365019
- US patents US 7,656,917 B; US 7,696,468 B; US 8,520,221 B; US 10,304,307B
- Approvals TÜV Süd
- Test procedure for continuous shock in accordance with standard IEC 60068-2-29
- Relative humidity (non-condensing) 15 ... 95 %
- Test procedure for EMC in accordance with standard DIN 40839-1/3; EN 61496-1
- Protection class III, EN 61140
- Test procedure for oscillation in accordance with standard EN 60068-2-6
- Ambient temperature, storage -20 ... 60 °C
- Degree of protection IP 65
- Ambient temperature, operation 0 ... 50 °C
- Operational controls Software Sensor Studio
- Type of configuration Software Sensor Studio
- Number of LEDs 6 Piece(s)
- Housing material Metal; Plastic
- Housing color Yellow, RAL 1021
- Dimension (W x H x L) 140 mm x 149 mm x 140 mm
- Metal housing Diecast zinc
- Type of display Alphanumerical display; LED indicator
- Type of fastening Mounting plate; Through-hole mounting; Via optional mounting device
- Net weight 3,000 g
- Wire cross section signals 0.14 mm²
- Encoding D-coded
- Lens cover material Plastic/PC
- Cable resistance, max. 15 Ω
- Cable color Black
- Material Metal
- Wire cross section supply 1 mm²
- Thread size M12
- No. of pins 4 -pin
- Number of connections 2 Piece(s)
- Type of connection Cable
- Number of conductors 29 -wire
- Cable length ≤ 5m; Longer cable lengths are possible using active cables.
- Radiated transmitting power Max. 4.5 dBm (2.82 mW), class 2
- Sheathing material PVC
- Transmission speed, max. 12 Mbit/s
- Connection M12 connector, 4-pin, D-coded
- Frequency band 2,400 ... 2,483.5 MHz
- Function Configuration/parametization; TCP/IP
- Voltage type DC
- Switching element Transistor, PNP
- Power consumption, max. 17 W, For 24 V, plus output load
- Response time 80 ms, ≥
- Number of signal outputs, configurable 9 Piece(s)
- Switching current, max. 300 mA
- Protective circuit Overvoltage protection
- Switching voltage high, min. 20.8 V
- Switching voltage low, max. 2 V
- Number of safety-related switching outputs (OSSDs) 4 Piece(s)
- Supply voltage UB 24 V, DC, -30 ... 20 %
- Current consumption (without load), max. 700 mA, (use power supply unit with 3 A)
- Laser spot (H x W), 20 m 165 mm x 24 mm
- Laser spot (H x W), 40 m 285 mm x 57 mm
- Measurement value noise 10 mm 1 σ; (• Diffuse reflection: 1.8% … 20%; Measurement range: 0 … 9 m; • Diffuse reflection: 20% … retro-reflector; Measurement range: 0 … 25 m)
- Laser spot (H x W), 30 m 265 mm x 40 mm
- Systematic measurement error Dmeas - Dreal min.: -20 mm; typ.: -10 mm; max.: 0 mm; , (Diffuse reflection: 1.8% … retro-reflector; Measurement range: 0.2 … 25 m)
- Laser spot (H x W), 10 m 60 mm x 13 mm
- Distance resolution, radial 1 mm
- Detection range 0 ... 50 m, Diffuse reflection > 90%
- Distance resolution, lateral 0.1 °
- Diffuse reflection 90 %
- Scanning angle 270 °
- Angular resolution 0.1 °
- Laser class 1, IEC/EN 60825-1:2014
- Repetition frequency 90 kHz
- Transmitted-signal shape Pulsed
- Wavelength 905 nm
- Object size 150 mm x 150 mm
- Light source Laser, Infrared
- Operating range 0 ... 8.25 m
- Number of field pairs Up to 100
- Number of quads, switchable 50
- Number of independent sensor configurations Up to 10
- Diffuse reflection, min. 1.8 %
- Resolution (adjustable) 30/40/50/60/70/150 mm
- Category 3, EN ISO 13849
- Number of protective functions 2 Piece(s)
- Minimum adjustable range 50 mm
- PFHD 9E-08 per hour
- Number of field pairs, switchable Up to 100
- Mission time 20 years, EN ISO 13849-1
- SILCL 2, IEC/EN 62061
- Series RSL 400
- Special version Measurement data output optimized for vehicle navigation
- Functions Data output, configurable; Dynamic contactor monitoring (EDM), selectable; E-stop linkage; Four-field mode; Safe time delay, internal
- SIL 2, IEC 61508
- Application Mobile danger zone guarding; Mobile side guarding; Stationary access guarding; Stationary danger zone guarding
- Performance Level (PL) d, EN ISO 13849-1
- Type 3, IEC/EN 61496
- Restart Start/restart interlock (RES), selectable
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
RSL445-XL/CU429-25 Description
RSL445-XL/CU429-25 Leuze - Safety laser scanner
Related documents RSL445-XL/CU429-25 Specs
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Leuze
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Leuze Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Leuze Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Leuze, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨