SLE46C-70.K4/4P Leuze Safety Light Curtains
Part#:SLE46C-70.K4/4P
Manufacturer:Leuze
Alt. Part#:50126329
Product Lifecycle:Active
Get a quick Quote!
SLE46C-70.K4/4P Leuze - Single light beam safety device receiver
Check out the SLE46C-70.K4/4P Leuze price in the box on the right side or send a quick quote.
Product Details
- Customs tariff number 85365019
- Standards applied IEC 60947-5-2, IEC/EN 61496
- Approvals c TÜV NRTL US; c UL US
- Degree of protection IP 67; IP 69K
- Protection class III, Rating voltage 50 V
- Ambient temperature, storage -30 ... 70 °C
- Ambient temperature, operation -30 ... 60 °C
- Number of LEDs 2 Piece(s)
- Housing material Plastic
- Type of display LED
- Plastic housing PC-PBT
- Lens cover material Plastic / PMMA
- Housing color Yellow
- Type of connection Cable
- Net weight 100 g
- Compatibility of materials ECOLAB
- Type of fastening Through-hole mounting
- Sheathing material PUR
- Dimension (W x H x L) 20.5 mm x 76.3 mm x 44 mm
- Design Cubic
- Number of conductors 4 -wire
- Wire cross section 0.21 mm²
- Cable length 2,000 mm
- Number of connections 1 Piece(s)
- Switching element Transistor, PNP
- Response time 2.5 ms
- Switching principle Dark switching
- Readiness delay 300 ms
- Switching frequency 250 Hz
- Function Diagnostic output
- Voltage type DC
- Supply voltage UB 24 V, DC, -20 ... 20 %, Incl. residual ripple
- Number of digital switching outputs 2 Piece(s)
- Switching voltage high: ≥(UB-2V); low: ≤ 2 V
- Switching voltage, type. 23 V
- Switching current, max. 100 mA
- Switching voltage high, min. 22 V
- Switching voltage low, max. 2 V
- Functions Alignment indicator; Diagnostic output
- Residual ripple 10 %, From UB
- Series 46C
- Protective circuit Polarity reversal protection; Short circuit protected
- Open-circuit current 0 ... 15 mA
- Performance Level (PL) e, EN ISO 13849-1:2008, In combination with MSI-TRMB safety relay
- Type 4, IEC/EN 61496, in combination with MSI-TRMB safety relay, In combination with MSI-TRMB safety relay
- MTTFd 900 years, EN ISO 13849-1
- Category 4, EN ISO 13849:2008, In combination with MSI-TRMB safety relay
- Mission time 20 years, EN ISO 13849-1
- SIL 3, IEC 61508, in combination with MSI-TRMB safety relay, In combination with MSI-TRMB safety relay
- SILCL 3, IEC/EN 62061, in combination with MSI-TRMB safety relay, In combination with MSI-TRMB safety relay
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
SLE46C-70.K4/4P Description
SLE46C-70.K4/4P Leuze - Single light beam safety device receiver
Related documents SLE46C-70.K4/4P Specs
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Leuze
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Leuze Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Leuze Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Leuze, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨