1045933 Phoenix Contact Terminal Blocks

Phoenix Contact 1045933 Distribution block, Basic terminal block, nom. voltage: 450 V, nominal current: 17.5 A, connection method: Push-in connection, number of connections: 2, cross section: 0.14 mm² - 2.5 mm², AWG: 26 - 14, width: 4.2 mm, height: 17.7 mm, color: black/yellow,
Phoenix Contact

Part#:1045933

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 13

Dec 26, 2024

Distribution block, Basic terminal block, nom. voltage: 450 V, nominal current: 17.5 A, connection method: Push-in connection, number of connections: 2, cross section: 0.14 mm² - 2.5 mm², AWG: 26 - 14, width: 4.2 mm, height: 17.7 mm, color: black/yellow,

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1045933 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Potentials
    1
  • Number of connections
    2
  • Rated surge voltage
    6 kV
  • Maximum total current
    21 A
  • Maximum load current
    21 A (with a 2.5 mm² conductor cross section)
  • Finger protection
    guaranteed
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Setpoint
    1 N
  • Insulating material
    PA
  • Insulating material group
    I
  • Nominal voltage UN
    450 V
  • Back of the hand protection
    guaranteed
  • Tensile test result
    Test passed
  • Nominal cross section
    1.5 mm²
  • Maximum power dissipation for nominal condition
    0.56 W
  • Number of levels
    1
  • Color
    black/yellow
  • Degree of pollution
    3
  • Overvoltage category
    III
  • Open side panel
    No
  • Result of surge voltage test
    Test passed
  • Result of power-frequency withstand voltage test
    Test passed
  • Bending test rotation speed
    10 rpm
  • Result of temperature-rise test
    Test passed
  • Result of voltage-drop test
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Shock test result
    Test passed
  • Number of shocks per direction
    3
  • Length
    21.6 mm
  • Flammability rating according to UL 94
    V0
  • Nominal current IN
    17.5 A
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Bending test turns
    135
  • Result of tight fit on support
    Test passed
  • Short circuit stability result
    Test passed
  • Result of thermal test
    Test passed
  • Oscillation, broadband noise test result
    Test passed
  • ASD level
    6.12 (m/s2)2/Hz
  • Test duration per axis
    5 h
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Connection in acc. with standard
    IEC 60998-2-2
  • Conductor cross section flexible min.
    0.14 mm²
  • Conductor cross section AWG max.
    14
  • Min. AWG conductor cross section, flexible
    26
  • Acceleration
    30g
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2018-05
  • Static insulating material application in cold
    -60 °C
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Connection method
    Push-in connection
  • Conductor cross section flexible max.
    1.5 mm²
  • Max. AWG conductor cross section, flexible
    14
  • Internal cylindrical gage
    A1 / B1
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 5.0
    27141120
  • ECLASS 4.0
    27141120
  • ECLASS 9.0
    27141120
  • UNSPSC 7.0901
    39121410
  • UNSPSC 6.01
    30211811
  • Shock duration
    18 ms
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Height
    17.7 mm
  • Stripping length
    8 mm ... 10 mm
  • Conductor cross section solid min.
    0.34 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.34 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    1.5 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Connection cross sections directly pluggable
    0.34 mm² 2.5 mm² 26 14
  • ECLASS 11.0
    27141120
  • ECLASS 5.1
    27141120
  • ETIM 2.0
    EC000897
  • ETIM 4.0
    EC000897
  • UNSPSC 12.01
    39121410
  • UNSPSC 18.0
    39121410
  • Tight fit on carrier
    NS 35/NS 15
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.34 mm²
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • Short-time current
    0.3 kA
  • Shock form
    Half-sine
  • Width
    4.2 mm
  • Conductor cross section AWG min.
    26
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    1.5 mm²
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 7.0
    27141120
  • ETIM 6.0
    EC000897
  • UNSPSC 13.2
    39121410
  • Result of flexion and pull-out test
    Test passed
  • Bending test conductor cross section/weight
    0.14 mm² / 0.2 kg
  • Result of aging test
    Test passed
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2018-05
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Conductor cross section solid max.
    2.5 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ECLASS 6.0
    27141100
  • ETIM 7.0
    EC000897
  • UNSPSC 11
    39121410
  • UNSPSC 21.0
    39121410
  • Conductor cross section short circuit testing
    2.5 mm²
  • ECLASS 10.0.1
    27141120
  • ECLASS 4.1
    27141120
  • ETIM 3.0
    EC000897
  • UNSPSC 20.0
    39121410
  • UNSPSC 19.0
    39121410

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$1.03

Stock:

13

Select Qty:

$1.03

$1.03 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo