Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

1047419 Phoenix Contact Terminal Blocks

Phoenix Contact 1047419 Distribution block, Basic terminal block with supply, nominal current: 41 A, connection method: Push-in connection, Push-in connection, number of connections: 19, cross section: 0.2 mm² - 6 mm², AWG: 24 - 10, width: 43.9 mm, height: 17.7 mm, color: blue,
Phoenix Contact

Part#:1047419

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 20

Dec 22, 2024

Distribution block, Basic terminal block with supply, nominal current: 41 A, connection method: Push-in connection, Push-in connection, number of connections: 19, cross section: 0.2 mm² - 6 mm², AWG: 24 - 10, width: 43.9 mm, height: 17.7 mm, color: blue,

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1047419 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Shock form
    Half-sine
  • Insulating material
    PA
  • Insulating material group
    I
  • Nominal voltage UN
    450 V
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Color
    blue
  • Number of connections
    19
  • Nominal cross section feed-in
    4 mm²
  • Rated surge voltage
    6 kV
  • Overvoltage category
    III
  • Open side panel
    No
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2018-05
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2018-05
  • Shock duration
    18 ms
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Height
    17.7 mm
  • Connection
    Pick-off level
  • Nominal cross section
    1.5 mm²
  • Degree of pollution
    3
  • Nominal current IN
    17.5 A
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Test duration per axis
    5 h
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Shock test result
    Test passed
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Static insulating material application in cold
    -60 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Width
    43.9 mm
  • Stripping length
    8 mm ... 10 mm
  • Connection in acc. with standard
    IEC 60998-2-2
  • Conductor cross section flexible max.
    1.5 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.14 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    1.5 mm²
  • Internal cylindrical gage
    A3
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 9.0
    27141120
  • ETIM 7.0
    EC000897
  • Number of levels
    1
  • Flammability rating according to UL 94
    V0
  • Maximum load current
    22 A (with a 2.5 mm² conductor cross section)
  • Maximum total current
    32 A
  • Result of thermal test
    Test passed
  • Oscillation, broadband noise test result
    Test passed
  • ASD level
    6.12 (m/s2)2/Hz
  • Acceleration
    30g
  • Number of shocks per direction
    3
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Length
    21.6 mm
  • Connection method
    Push-in connection
  • Conductor cross section solid min.
    0.34 mm²
  • Conductor cross section AWG max.
    14
  • Conductor cross section flexible min.
    0.14 mm²
  • Min. AWG conductor cross section, flexible
    26
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    1.5 mm²
  • Value
    0.34 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 10.0.1
    27141120
  • ECLASS 11.0
    27141120
  • Conductor cross section solid max.
    2.5 mm²
  • Conductor cross section AWG min.
    26
  • Max. AWG conductor cross section, flexible
    14
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.14 mm²
  • Connection cross sections directly pluggable
    0.34 mm² 2.5 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ETIM 6.0
    EC000897

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$10.25

Stock:

20

Select Qty:

$10.25

$10.25 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo