1078960 Phoenix Contact Terminal Blocks

Phoenix Contact 1078960 Feed-through terminal block, nom. voltage: 800 V, nominal current: 24 A, connection method: Push-in connection, number of connections: 2, number of positions: 1, cross section: 0.14 mm² - 4 mm², AWG: 26 - 12, width: 5.2 mm, height: 35.3 mm, color: gray, m
Phoenix Contact

Part#:1078960

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 2817

Dec 23, 2024

Feed-through terminal block, nom. voltage: 800 V, nominal current: 24 A, connection method: Push-in connection, number of connections: 2, number of positions: 1, cross section: 0.14 mm² - 4 mm², AWG: 26 - 12, width: 5.2 mm, height: 35.3 mm, color: gray, m

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1078960 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Number of connections
    2
  • Area of application
    Railway industry
  • Nominal cross section
    2.5 mm²
  • Insulating material
    PA
  • Rated surge voltage
    8 kV
  • Finger protection
    guaranteed
  • Surge voltage test setpoint
    9.8 kV
  • Bending test turns
    135
  • Result of voltage-drop test
    Test passed
  • Short circuit stability result
    Test passed
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Shock duration
    18 ms
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Height NS 35/7,5
    36.8 mm
  • Stripping length
    8 mm ... 10 mm
  • Conductor cross section AWG max.
    12
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    2.5 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 4.0
    27141121
  • ECLASS 7.0
    27141120
  • UNSPSC 7.0901
    39121410
  • UNSPSC 18.0
    39121410
  • Potentials
    1
  • Maximum load current
    28 A (with 4 mm² conductor cross section, rigid)
  • Result of surge voltage test
    Test passed
  • Result of flexion and pull-out test
    Test passed
  • Conductor cross section tensile test
    4 mm²
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Short-time current
    0.3 kA
  • Result of aging test
    Test passed
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2018-05
  • Acceleration
    30g
  • Shock test result
    Test passed
  • Number of shocks per direction
    3
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Height
    35.3 mm
  • Height NS 35/15
    44.3 mm
  • Conductor cross section AWG min.
    26
  • Min. AWG conductor cross section, flexible
    26
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    2.5 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • ECLASS 10.0.1
    27141120
  • ECLASS 4.1
    27141121
  • ECLASS 9.0
    27141120
  • ETIM 6.0
    EC000897
  • UNSPSC 6.01
    30211811
  • UNSPSC 19.0
    39121410
  • ETIM 7.0
    EC000897
  • Number of positions
    1
  • Color
    gray
  • Degree of pollution
    3
  • Open side panel
    Yes
  • Nominal voltage UN
    800 V
  • Result of power-frequency withstand voltage test
    Test passed
  • Bending test rotation speed
    10 rpm
  • Result of tight fit on support
    Test passed
  • Result of temperature-rise test
    Test passed
  • Result of thermal test
    Test passed
  • ASD level
    6.12 (m/s2)2/Hz
  • Test duration per axis
    5 h
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Width
    5.2 mm
  • Connection
    1 level
  • Connection in acc. with standard
    IEC 60947-7-1
  • Conductor cross section flexible max.
    4 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    1.5 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    1 mm²
  • Connection cross sections directly pluggable
    0.5 mm² 4 mm² 20 12
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 5.1
    27141100
  • ETIM 3.0
    EC000897
  • ETIM 2.0
    EC000897
  • UNSPSC 12.01
    39121410
  • UNSPSC 13.2
    39121410
  • Number of levels
    1
  • Flammability rating according to UL 94
    V0
  • Overvoltage category
    III
  • Nominal current IN
    24 A (at 2.5 mm²)
  • Back of the hand protection
    guaranteed
  • Power frequency withstand voltage setpoint
    2 kV
  • Bending test conductor cross section/weight
    0.14 mm² / 0.2 kg
  • Tight fit on carrier
    NS 35
  • Conductor cross section short circuit testing
    2.5 mm²
  • Oscillation, broadband noise test result
    Test passed
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Static insulating material application in cold
    -60 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Length
    50.8 mm
  • Connection method
    Push-in connection
  • Conductor cross section solid min.
    0.5 mm²
  • Conductor cross section flexible min.
    0.14 mm²
  • Internal cylindrical gage
    A3
  • ECLASS 11.0
    27141120
  • ECLASS 6.0
    27141100
  • UNSPSC 20.0
    39121410
  • UNSPSC 21.0
    39121410
  • Insulating material group
    I
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Tensile test result
    Test passed
  • Tractive force setpoint
    60 N
  • Requirements, voltage drop
    U1 ≤ 3.2 mV; U2 ≤ 1.5 x U1
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Shock form
    Half-sine
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • End cover width
    2.2 mm
  • Conductor cross section solid max.
    4 mm²
  • Max. AWG conductor cross section, flexible
    12
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    1.5 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 5.0
    27141120
  • ETIM 4.0
    EC000897
  • UNSPSC 11
    39121410

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$2.05

Stock:

2,817

Select Qty:

$2.05

$2.05 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo