Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

1087569 Phoenix Contact Electrical Safety Devices

Phoenix Contact 1087569 Safety relay module with IO-Link for emergency stop, safety doors, and light grids, to SILCL 3, Cat. 4, PL e, 2 sensor circuits, automatic or manual, monitored start, 2 safe digital outputs, 1 signal output, US = 24 V DC, pluggable Push-in terminal block
Phoenix Contact

Part#:1087569

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Safety relay module with IO-Link for emergency stop, safety doors, and light grids, to SILCL 3, Cat. 4, PL e, 2 sensor circuits, automatic or manual, monitored start, 2 safe digital outputs, 1 signal output, US = 24 V DC, pluggable Push-in terminal block

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1087569 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Depth
    114.5 mm
  • Power consumption at US
    typ. 1.73 W
  • Current consumption
    < 7 mA (Typically with US at S34)
  • Number of inputs
    1
  • Ambient temperature (operation)
    -40 °C ... 60 °C (observe derating)
  • Maximum altitude
    ≤ 2000 m (Above sea level)
  • Filter time
    max. 1.5 ms (Test pulse width of low test pulses)
  • Input name
    C/Q
  • Input current range "0" signal
    0 mA ... 2 mA
  • Cycle Time
    5 ms
  • Connection method
    Push-in connection
  • Width
    17.5 mm
  • Max. permissible relative humidity (operation)
    75 % (on average, 85% infrequently, non-condensing)
  • Designation
    Air clearances and creepage distances between the power circuits
  • Inrush current
    max. 4.8 A (Δt = 10 ms)
  • Type of protection
    Freewheeling circuit for inductive loads
  • Concurrence
  • Amount of process data
    max. 31 Byte (Input data)
  • Output description
    Safety-related digital outputs
  • Output voltage
    ≥ 23 V DC (Us - 1 V)
  • Max. inductive load
    max. 1 H
  • Ohmic load
    min. 12 Ω
  • Limitation of the voltage induced on circuit interruption
    max. 50 V
  • Restart time
    < 1 s (Boot time)
  • Mounting type
    DIN rail mounting
  • Min. degree of protection of inst. location
    IP54
  • Conductor cross-section flexible with ferrule without plastic sleeve
    0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
  • Stripping length
    8 mm
  • Rated insulation voltage
    63 V
  • Degree of pollution
    2
  • ECLASS 9.0
    27371819
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Rated control circuit supply voltage US
    24 V DC -20 % / +25 % (provide external protection)
  • Protective circuit
    Parallel protection against polarity reversal Suppressor diode Provide external fuse protection, see safety notes. Fuse type: 5 AT
  • Description of the input
    IO-Link switching and communication cable
  • Max. permissible overall conductor resistance
    150 Ω
  • Process data update
    5 ms
  • Number of outputs
    2
  • Output voltage when switched off
    < 5 V DC (in the safe state)
  • Max. capacitive load
    max. 10 µF (2.4 A load)
  • Switching frequency
    1 Hz (Resistive, inductive, capacitive)
  • Discharging circuit
    No
  • Recovery time
    250 ms (following demand of the safety function)
  • Assembly instructions
    See derating curve
  • Housing color
    yellow
  • Status display
    5x LED green
  • Category
    4
  • Overvoltage category
    II
  • Conformance
    CE-compliant
  • Height
    116.6 mm
  • Max. permissible humidity (storage/transport)
    75 % (on average, 85% infrequently, non-condensing)
  • Rated control supply current IS
    typ. 72 mA
  • Nominal voltage for I/O supply
    24 V DC -20 % / +25 % (is provided via the IO-Link interface of the IO-Link master.)
  • Protective circuit/component
    Suppressor diode
  • Input voltage range "0" signal
    0 V DC ... 5 V DC
  • Input voltage range
    0 V DC ... 30 V DC
  • Transmission speed
    230 kbps (COM3)
  • Number of ports
    1
  • Port type
    Class A
  • Output name
    14, 24
  • Short-circuit protection
    Yes
  • Voltage
    approx. 22 V DC
  • Net weight
    126.06 g
  • Operating voltage display
    1 x green, yellow, red LED
  • pluggable
    Yes
  • Conductor cross-section AWG
    24 ... 16
  • Stop category
    0
  • Vibration (operation)
    10 Hz ... 150 Hz, 5g
  • ECLASS 11.0
    27371819
  • Input voltage range "1" signal
    19.2 V DC ... 30 V DC
  • Specification
    Version 1.1
  • Typical response time at US
    < 200 ms (automatic start)
  • Mounting position
    vertical or horizontal
  • Degree of protection
    IP20
  • Response time
    < 10 ms
  • Conductor cross section solid
    0.2 mm² ... 1.5 mm²
  • Conductor cross-section flexible with ferrule and plastic sleeve
    0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
  • Performance level (PL)
    e
  • Rated surge voltage/insulation
    Safe isolation, 0.5 kw between logic and IO-Link
  • ECLASS 10.0.1
    27371819
  • Connection technology
    3-conductor
  • Output current
    max. 2.4 A
  • Leakage current
    max. 1 mA (in the safe state)
  • Min. load current
    2 mA
  • Typical pickup time at US
    < 200 ms (when controlled via A1)
  • Nominal operating mode
    100% operating factor
  • Housing material
    PBT
  • Conductor cross section flexible
    0.2 mm² ... 1.5 mm²
  • Safety Integrity Level (SIL)
    3
  • Safety Integrity Level Claim Limit (SIL CL)
    3
  • Standards/regulations
    EN 60947-5-1
  • Shock
    30g

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo