1104974 Phoenix Contact Electrical Safety Devices
Part#:1104974
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 43
Dec 22, 2024
Configurable safety module (basic module), 8 safe inputs, 4 safe outputs, 4 reset inputs or 4 signal outputs, 4 clock outputs, can be extended via TBUS, up to SILCL 3, Cat. 4/PL e, SIL 3, plug-in screw terminal block, TBUS connector not included
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1104974 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Ambient temperature (storage/transport) -20 °C ... 85 °C
- Rated control supply current IS typ. 55 mA (Outputs inactive)
- Depth 113.6 mm
- Designation Air clearances and creepage distances between the power circuits
- Inrush current max. 600 mA (Δt < 10 ms)
- Number of inputs 4
- Output description PNP, IEC 61131-2 Typ 0,1
- Limiting continuous current 100 mA (per channel)
- Max. inductive load max. 2.4 mH
- Short-circuit protection Yes (self-limitation at 1.1 A)
- Restart time min. 5 s (Boot time)
- Net weight 159 g
- Degree of protection IP20
- Status display 1 x LED (green), 1 x LED (orange), 1 x LED (blue)
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Stripping length 7 mm
- Performance level (PL) e (2-channel wiring)
- Overvoltage category II
- Width 22.61 mm
- Maximum altitude ≤ 2000 m (Above sea level)
- Current consumption typ. 12 mA (typically with US)
- Input name Reset inputs
- Input voltage range "0" signal 0 V DC ... 5 V DC
- Max. permissible overall conductor resistance 1.2 kΩ (Input and reset circuit at US)
- Nominal output voltage range 18.5 V DC ... 28.1 V DC (US - 0,7 V)
- Output voltage when switched off max. 0.1 V
- Test pulses ≤ 200 µs (Test pulse duration)
- Maximum inrush current 1.1 A (Δt = 3 s at Us)
- Assembly instructions Observe derating
- Housing material Polyamide PA non-reinforced
- Indication 2 x LED (red)
- Screw thread M3
- Safety Integrity Level (SIL) 2
- Rated surge voltage/insulation Basic insulation 4 kV between all current paths and housing
- Shock 10g for Δt = 16 ms (continuous shock, 1000 shocks in each space direction)
- ECLASS 9.0 27371819
- Height 112.58 mm
- Max. permissible relative humidity (operation) 95 % (non-condensing)
- Rated control circuit supply voltage US 24 V DC -20 % / +20 % (provide external protection, typically 5 A)
- Power consumption at US typ. 1.32 W (Outputs inactive)
- Input current range "0" signal < 1 mA
- Output name O1, O2, O3, O4
- Leakage current max. 100 µA
- Max. capacitive load max. 470 nF
- Output voltage range 18.2 V DC ... 27.8 V DC (US - 1 V)
- Nominal voltage range 18.2 V DC ... 27.8 V DC (US - 1 V)
- Nominal operating mode 100% operating factor
- Min. degree of protection of inst. location IP54
- Connection method Screw connection
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Safety Integrity Level Claim Limit (SIL CL) 3 (2-channel wiring)
- Rated insulation voltage 250 V AC
- ECLASS 11.0 27371819
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- Ambient temperature (operation) -10 °C ... 55 °C (observe derating)
- Max. permissible humidity (storage/transport) 95 % (non-condensing)
- Filter time 250 ms ±2 ms (Test pulse rate > 500 ms)
- Input voltage range "1" signal 11 V DC ... 28.8 V DC
- Protective circuit/component Suppressor diode
- Nominal output voltage 24 V DC (Supply via A1)
- Ohmic load min. 50 Ω (Observe limiting continuous current)
- Error detection time at 1-channel structure < 3.5 s (OFF state)
- Discharging circuit Yes, internal
- Mounting position vertical or horizontal
- Protection class III (EN 50178)
- Operating voltage display 1 x green LED
- Conductor cross-section AWG 24 ... 12
- Torque 0.5 Nm ... 0.6 Nm
- Standards/regulations EN 50178
- Vibration (operation) 10 Hz ... 150 Hz, 2g
- ECLASS 10.0.1 27371819
- Protective circuit Serial protection against polarity reversal
- Description of the input configurable (as signal output or reset input)
- Cable length max. 100 m (per output)
- Number of outputs 4
- Switching frequency max. 1/4 x tCycle [Hz]
- Voltage 24 V DC (via A1)
- Response time see user manual
- Cycle time see user manual
- Mounting type DIN rail mounting
- Housing color yellow
- pluggable Yes
- Stop category 0
- Degree of pollution 2
- Conformance CE-compliant
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$751.86
Stock:
43
Select Qty:
$751.86
$751.86 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.