1104975 Phoenix Contact Electrical Safety Devices
Part#:1104975
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 50
Dec 22, 2024
Configurable safety module (basic module), 8 safe inputs, 4 safe outputs, 4 reset inputs or 4 signal outputs, 4 clock outputs, can be extended via TBUS, up to SILCL 3, Cat. 4/PL e, SIL 3, plug-in Push-in terminal block, TBUS connector not included
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1104975 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height 107.74 mm
- Max. permissible relative humidity (operation) 95 % (non-condensing)
- Rated control circuit supply voltage US 24 V DC -20 % / +20 % (provide external protection, typically 5 A)
- Width 22.61 mm
- Maximum altitude ≤ 2000 m (Above sea level)
- Max. permissible humidity (storage/transport) 95 % (non-condensing)
- Inrush current max. 600 mA (Δt < 10 ms)
- Description of the input configurable (as signal output or reset input)
- Input current range "0" signal < 1 mA
- Nominal output voltage 24 V DC (Supply via A1)
- Leakage current max. 100 µA
- Max. inductive load max. 2.4 mH
- Output voltage range 18.2 V DC ... 27.8 V DC (US - 1 V)
- Response time see user manual
- Housing color yellow
- Ambient temperature (storage/transport) -20 °C ... 85 °C
- Designation Air clearances and creepage distances between the power circuits
- Input name Reset inputs
- Protective circuit Serial protection against polarity reversal
- Protective circuit/component Suppressor diode
- Cable length max. 100 m (per output)
- Limiting continuous current 100 mA (per channel)
- Output voltage when switched off max. 0.1 V
- Maximum inrush current 1.1 A (Δt = 3 s at Us)
- Cycle time see user manual
- Assembly instructions Observe derating
- Degree of protection IP20
- Status display 1 x LED (green), 1 x LED (orange), 1 x LED (blue)
- Conductor cross-section AWG 24 ... 16
- Stop category 0
- Conformance CE-compliant
- ECLASS 11.0 27371819
- Ambient temperature (operation) -10 °C ... 55 °C (observe derating)
- Rated control supply current IS typ. 55 mA (Outputs inactive)
- Input voltage range "1" signal 11 V DC ... 28.8 V DC
- Output name O1, O2, O3, O4
- Ohmic load min. 50 Ω (Observe limiting continuous current)
- Switching frequency max. 1/4 x tCycle [Hz]
- Discharging circuit Yes, internal
- Restart time min. 5 s (Boot time)
- Mounting type DIN rail mounting
- Connection method Push-in connection
- Stripping length 10 mm
- Performance level (PL) e (2-channel wiring)
- Overvoltage category II
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- Depth 113.6 mm
- Current consumption typ. 12 mA (typically with US)
- Power consumption at US typ. 1.32 W (Outputs inactive)
- Number of inputs 4
- Max. permissible overall conductor resistance 1.2 kΩ (Input and reset circuit at US)
- Number of outputs 4
- Max. capacitive load max. 470 nF
- Short-circuit protection Yes (self-limitation at 1.1 A)
- Voltage 24 V DC (via A1)
- Nominal voltage range 18.2 V DC ... 27.8 V DC (US - 1 V)
- Housing material Polyamide PA non-reinforced
- Protection class III (EN 50178)
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- pluggable Yes
- Standards/regulations EN 50178
- Vibration (operation) 10 Hz ... 150 Hz, 2g
- ECLASS 9.0 27371819
- Filter time 250 ms ±2 ms (Test pulse rate > 500 ms)
- Input voltage range "0" signal 0 V DC ... 5 V DC
- Output description PNP, IEC 61131-2 Typ 0,1
- Nominal output voltage range 18.5 V DC ... 28.1 V DC (US - 0,7 V)
- Test pulses ≤ 200 µs (Test pulse duration)
- Error detection time at 1-channel structure < 3.5 s (OFF state)
- Net weight 141 g
- Nominal operating mode 100% operating factor
- Min. degree of protection of inst. location IP54
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Safety Integrity Level (SIL) 2
- Rated surge voltage/insulation Basic insulation 4 kV between all current paths and housing
- Shock 10g for Δt = 16 ms (continuous shock, 1000 shocks in each space direction)
- Mounting position vertical or horizontal
- Operating voltage display 1 x green LED
- Indication 2 x LED (red)
- Safety Integrity Level Claim Limit (SIL CL) 3 (2-channel wiring)
- Rated insulation voltage 250 V AC
- Degree of pollution 2
- ECLASS 10.0.1 27371819
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 5 days!
1-year warranty
$658.04
Stock:
50
Select Qty:
$658.04
$658.04 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨