1110984 Phoenix Contact Electrical Circuit Protection & Load Centers

Phoenix Contact 1110984 Two-channel, electronic fuse for protecting loads at 12 and 24 V DC in the event of overload and short circuit. Nominal current adjustable from 2 A to 10 A via step switch. For DIN rail installation via the CAPAROC busbar modules.
Phoenix Contact

Part#:1110984

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 204

Dec 22, 2024

Two-channel, electronic fuse for protecting loads at 12 and 24 V DC in the event of overload and short circuit. Nominal current adjustable from 2 A to 10 A via step switch. For DIN rail installation via the CAPAROC busbar modules.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Circuit Protection & Load Centers that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1110984 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Ambient temperature (storage/transport)
    -40 °C ... 70 °C
  • Vibration (operation)
    5g (10 ... 150 Hz / 10 cycles / axis / X, Y, Z)
  • Protection class
    III
  • Fuse type
    electronic
  • Rated current IN
    10 A DC (per channel)
  • Fail-safe element
    15 A DC (per output channel)
  • Voltage drop
    0.14 V (at 10 A)
  • Channel LED off
    off (Channel switched off)
  • Channel LED red
    lit (Channel switched off, over- or undervoltage active)
  • Connection method
    Push-in connection
  • Standards/specifications
    EN 61000-6-2 EMC – Immunity for industrial areas
  • ECLASS 11.0
    27140401
  • Width
    12.4 mm
  • Shock (operation)
    30g (11 ms period, half-sine shock pulse, according to IEC 60068-2-27)
  • Color
    light grey RAL 7035
  • Operating voltage
    10 V DC ... 30 V DC
  • Measuring tolerance I
    ± 10 % (typ.)
  • Tripping method
    E (electronic)
  • Undervoltage switch-off load circuit
    ≤ 8.5 V DC (active)
  • Max. capacitive load load circuit
    ≤ 75000 µF (Depending on the current setting and the short-circuit current available)
  • Conductor cross section AWG
    24 ... 12
  • ECLASS 9.0
    27141116
  • Depth
    111.3 mm (incl. DIN rail 7.5 mm)
  • Flammability rating according to UL 94
    V-0
  • Degree of pollution
    2
  • Switch-on delay
    50 ms (each channel preset by default)
  • Feedback resistance
    max. 35 V DC
  • Closed circuit current I0
    typ. 25 mA (no load at 24 V)
  • Power dissipation
    typ. 0.6 W (no load at 24 V)
  • Short-circuit switching capacity
    300 A
  • MTBF (IEC 61709, SN 29500)
    11155723 h (at 25 °C with 21 % load)
  • Channel LED yellow
    lit (Channel switched on, channel load > 80% )
  • Connection name
    Fuse-protected output
  • Conductor cross section solid
    0.2 mm² ... 4 mm²
  • ECLASS 10.0.1
    27140401
  • Conductor cross section flexible, with ferrule without plastic sleeve
    0.25 mm² ... 4 mm²
  • Height
    132.4 mm
  • Humidity test
    96 h, 95 % RH, 40 °C
  • Degree of protection
    IP20
  • Number of positions
    1
  • Rated surge voltage
    0.5 kV
  • Efficiency
    > 99 %
  • Required backup fuse
    Only required if Imax of the power supply > the short-circuit switching capacity. Integrated failsafe element.
  • Shutdown time load circuit
    5 s (for overload 1.1…1.3 x IN at IN ≥ 4 A)
  • Channel LED red-green
    flashing (Channel switched off, programming mode active, current adjustment after overload or short-circuit release)
  • Conductor cross section, flexible, with ferrule, with plastic sleeve
    0.25 mm² ... 4 mm²
  • Ambient temperature (operation)
    -30 °C ... 65 °C (The temperature range of the power module must be taken into consideration)
  • Altitude
    ≤ 4000 m (amsl (above mean sea level))
  • Mounting type
    DIN rail: 35 mm
  • Rated voltage
    12 V DC
  • Active current limitation
    typ. 2.0 x IN at IN ≤ 3 A
  • Temperature derating
    20 A (Total current at 40°C)
  • Dielectric strength
    35 V DC (Load circuit)
  • Overvoltage switch-off shutdown load circuit
    ≥ 32.5 V DC (active)
  • Channel LED green
    lit (Channel switched on)
  • Channel LED red-yellow
    flashing (Channel is overloaded and is switched off)
  • Stripping length
    10 mm
  • REACh SVHC
    Lead 7439-92-1

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$109.95

Stock:

204

Select Qty:

$109.95

$109.95 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo