Safety relay for emergency stop and safety doors up to SILCL 3, Cat. 4, PL e, 1 or 2-channel operation, automatic or manual, monitored start, cross-circuit detection, 3 enabling current paths, US = 24 V DC, plug-in screw terminal block
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1218392 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- ECLASS 9.0 27371819
- Ambient temperature (operation) -40 °C ... 55 °C (observe derating)
- Rated control supply current IS typ. 84 mA
- Number of inputs 1
- Max. permissible overall conductor resistance 150 Ω
- Contact material AgSnO2
- Contact type 3 enabling current paths
- Switching frequency 0.5 Hz
- Mechanical service life 10x 106 cycles
- Typical response time at US < 175 ms (automatic start)
- Mounting position vertical or horizontal
- Housing material PBT
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Safety Integrity Level (SIL) 3
- Safety Integrity Level Claim Limit (SIL CL) 3
- Shock 15g
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Maximum altitude ≤ 2000 m (Above sea level)
- Power consumption at US typ. 2 W
- Description of the input non-safety-related
- Input voltage range "1" signal 20.4 V DC ... 26.4 V DC
- Protective circuit/component Suppressor diode
- Limiting continuous current 6 A (For 13/14)
- Sq. Total current 72 A2 (observe derating)
- Output fuse 6 A gL/gG (N/O contact)
- Typical pickup time at US < 250 ms (when controlled via A1)
- Typical release time at US < 20 ms (when controlled via A1 or S12 and S22.)
- Mounting type DIN rail mounting
- Status display 3 x green LED
- Conductor cross-section AWG 24 ... 12
- Stripping length 7 mm
- Rated insulation voltage 250 V AC
- Vibration (operation) 10 Hz ... 150 Hz, 2g
- Width 12.5 mm
- Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing)
- Rated control circuit supply voltage US 24 V DC -15 % / +10 %
- Filter time max. 1.5 ms (at S12, S22; test pulse width)
- Input current range "0" signal 0 mA ... 2 mA (for safe Off; at S12)
- Number of outputs 1 (digital, PNP)
- Switching capacity min. 60 mW
- Maximum inrush current 500 mA (Δt = 1 ms at Us)
- Relay type Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
- Min. degree of protection of inst. location IP54
- Operating voltage display 1 x green LED
- Screw thread M3
- Performance level (PL) e (4 A DC13; 5 A AC15; 8760 switching cycles/year)
- Standards/regulations DIN EN 50178
- ECLASS 10.0.1 27371819
- Depth 114.5 mm
- Max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing)
- Protective circuit Surge protection Suppressor diode
- Current consumption < 10 mA (at S34/24 V)
- Output description non-safety-related
- Current max. 100 mA
- Recovery time < 500 ms
- Net weight 144.92 g
- Degree of protection IP20
- Connection method Screw connection
- pluggable Yes
- Stop category 0
- Category 4
- Degree of pollution 2
- Conformance CE-compliant
- Environmental simulation test ISA-S71.04 (G3)
- Height 112.2 mm
- Designation Air clearances and creepage distances between the power circuits
- Inrush current min. 3 mA
- Input name Start circuit
- Input voltage range "0" signal 0 V DC ... 5 V DC (for safe Off; at S12)
- Output name Enabling current paths
- Switching voltage min. 12 V AC/DC
- Voltage 22 V DC (Us - 2 V)
- Short-circuit protection no
- Nominal operating mode 100% operating factor
- Assembly instructions See derating curve
- Housing color yellow
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Torque 0.6 Nm
- Rated surge voltage/insulation Basic insulation 4 kV:Between input circuit and enabling current path (23/24/34)Between all current paths and housingSafe isolation, reinforced insulation 6 kV:Between input circuit and enabling current path (13/14)Between enabling current path (13/14) an
- Overvoltage category III
- ECLASS 11.0 27371819
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Do you have questions?
We’re here for you ✨