Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

2702053 Phoenix Contact Programmable Logic Controllers

Phoenix Contact 2702053 Axioline F, Digital output module, Digital outputs: 64, 24 V DC, 500 mA, connection method: 1-conductor, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors
Phoenix Contact

Part#:2702053

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Axioline F, Digital output module, Digital outputs: 64, 24 V DC, 500 mA, connection method: 1-conductor, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2702053 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Output voltage
    24 V
  • Width
    53.6 mm
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Designation
    Supply for digital output modules (UO)
  • Note on the connection method
    Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
  • Height
    129.9 mm
  • Ambient temperature (operation)
    -25 °C ... 60 °C
  • Air pressure (storage/transport)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Air pressure (operation)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Conductor cross section flexible min.
    0.2 mm²
  • ECLASS 11.0
    27242604
  • ECLASS 7.0
    27242604
  • Conductor cross section solid min.
    0.2 mm²
  • Test section
    5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min.
  • Immunity to burst
    Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
  • Overvoltage category
    II (IEC 60664-1, EN 60664-1)
  • ETIM 6.0
    EC001599
  • UNSPSC 21.0
    32151602
  • Stripping length
    8 mm
  • Conductor cross section AWG min.
    24
  • Degree of pollution
    2 (IEC 60664-1, EN 60664-1)
  • Current consumption
    max. 16 A (Provide external protection; if the total current of 8 A is exceeded, connect the supply at the power connector parallel via both terminal points.)
  • Protective circuit
    Short-circuit protection, overload protection of the outputs electronic
  • Switching frequency
    max. 10000 per second (with ohmic load)
  • Nominal output voltage
    24 V DC
  • Output current when switched off
    max. 300 µA
  • Immunity to surge
    Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
  • Depth
    54 mm
  • Permissible humidity (storage/transport)
    5 % ... 95 % (non-condensing)
  • Conductor cross section flexible max.
    1.5 mm²
  • Caption
    Dimensions
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Degree of protection
    IP20
  • Transmission speed
    100 Mbps
  • Mounting position
    any (no temperature derating)
  • Nominal load, inductive
    max. 12 VA (1.2 H, 48 Ω, with nominal voltage)
  • Nominal load, ohmic
    max. 12 W (48 Ω, with nominal voltage)
  • Output voltage when switched off
    max. 1 V
  • REACh SVHC
    Lead 7439-92-1
  • Note on dimensions
    The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
  • Reverse voltage resistance to short pulses
    limited protection up to 0.5 A for 1 s
  • Immunity to ESD
    Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
  • Interference emission
    Noise emission test according to EN 61000-6-3 Class B
  • Connection method
    Push-in connection
  • Conductor cross section AWG max.
    16
  • Net weight
    260 g
  • Power consumption
    max. 480 W (of which 1.8 W internal losses)
  • Connection technology
    1-conductor
  • Load min.
    10 kΩ
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 10.0.1
    27242604
  • UNSPSC 19.0
    32151602
  • ETIM 7.0
    EC001599
  • Protection class
    III (IEC 61140, EN 61140, VDE 0140-1)
  • ECLASS 6.0
    27242600
  • UNSPSC 18.0
    32151602
  • Nominal load, lamp
    max. 12 W (at nominal voltage)
  • Behavior with inductive overload
    Output can be destroyed
  • Immunity to EF
    Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
  • Mechanical tests
    Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
  • UNSPSC 20.0
    32151602
  • Number of interfaces
    2
  • Note on weight specifications
    with connectors and bus base module
  • Supply voltage
    24 V DC
  • Output name
    Digital outputs
  • Supply voltage range
    19.2 V DC ... 30 V DC (including all tolerances, including ripple)
  • Color
    traffic grey A RAL 7042
  • Mounting type
    DIN rail
  • Behavior with overload
    Shutdown with automatic restart
  • Conductor cross section solid max.
    1.5 mm²
  • Protection
    max. 16 A (polarity reversal protection up to 5 A)
  • Immunity to conducted interference
    Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
  • ECLASS 9.0
    27242604
  • Number of outputs
    64
  • UNSPSC 13.2
    32151602
  • ECLASS 5.1
    27242600

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo