2702502 Phoenix Contact Programmable Logic Controllers

Phoenix Contact 2702502 Inline ECO, Temperature measurement terminal, Analog UTH inputs: 4 (Type J), connection method: 2-conductor, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connector
Phoenix Contact

Part#:2702502

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 27

Dec 22, 2024

Inline ECO, Temperature measurement terminal, Analog UTH inputs: 4 (Type J), connection method: 2-conductor, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connector

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2702502 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Ambient temperature (storage/transport)
    -25 °C ... 85 °C
  • Mounting type
    DIN rail
  • Color
    green
  • Transmission speed
    500 kbps
  • Number of inputs
    4 (Type J)
  • Sensor types that can be used (TC)
    J
  • Measuring principle
    Sigma/Delta process
  • Height
    119.8 mm
  • Air pressure (storage/transport)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Ambient temperature (operation)
    0 °C ... 55 °C
  • Permissible humidity (storage/transport)
    10 % ... 95 % (according to DIN EN 61131-2)
  • Net weight
    69 g
  • Connection method
    Inline connector
  • Number
    2
  • ECLASS 4.1
    27250303
  • Width
    12.2 mm
  • Degree of protection
    IP20
  • Input name
    Analog UTH inputs
  • Description of the input
    Differential inputs
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Depth
    71.5 mm
  • Air pressure (operation)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Note on weight specifications
    with connector
  • Supply voltage
    24 V DC (via voltage jumper)
  • A/D converter resolution
    24 bit
  • Immunity to conducted interference
    Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
  • ECLASS 10.0.1
    27242601
  • ECLASS 5.0
    27250303
  • ECLASS 9.0
    27242601
  • UNSPSC 6.01
    43172015
  • ETIM 6.0
    EC001596
  • Connection technology
    2-conductor
  • Measured value representation
    16 bits (15 bits + sign bit)
  • Process data update
    < 10 ms
  • Protection class
    III (IEC 61140, EN 61140, VDE 0140-1)
  • ECLASS 6.0
    27242600
  • Test section
    Bus logic (local bus, communications power) 500 V AC 50 Hz 1 min.
  • Immunity to burst
    Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
  • ETIM 2.0
    EC001431
  • UNSPSC 18.0
    32151602
  • UNSPSC 19.0
    32151602
  • Permissible humidity (operation)
    10 % ... 95 % (according to DIN EN 61131-2)
  • Supply voltage range
    19.2 V DC ... 30 V DC (including all tolerances, including ripple)
  • REACh SVHC
    Lead 7439-92-1
  • Designation
    Supply of analog modules (UANA)
  • Power consumption
    typ. 1.05 W (total)
  • ECLASS 7.0
    27242601
  • Diagnostics messages
    Failure of the internal I/O supply I/O error message sent to the bus coupler
  • Current consumption
    typ. 32 mA
  • Note regarding the connection technology
    shielded
  • Type of protection
    Transient protection of inputs
  • A/D conversion time
    typ. 120 ms
  • Immunity to ESD
    Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
  • ETIM 7.0
    EC001596
  • UNSPSC 12.01
    43201404
  • UNSPSC 13.2
    32151602
  • Immunity to surge
    Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, supply lines DC: ±1  kV/±1 kV (symmetrical/asymmetrical), shielded I/O cables: ±1 kV
  • Immunity to EF
    Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
  • ECLASS 11.0
    27242601
  • ECLASS 4.0
    27250303
  • UNSPSC 7.0901
    43201404
  • UNSPSC 20.0
    32151602
  • Interference emission
    Noise emission test as per EN 61000-6-4 Class A
  • ECLASS 5.1
    27242601
  • ETIM 3.0
    EC001596
  • ETIM 4.0
    EC001596
  • UNSPSC 11
    43172015
  • UNSPSC 21.0
    32151602

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$413.44

Stock:

27

Select Qty:

$413.44

$413.44 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo