2702523 Phoenix Contact Electrical Safety Devices
Part#:2702523
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
Coupling relay for electrical isolation and power adaptation for SIL 3 F&G applications, low demand, load diagnostics in the Off and On state for wire break and short circuit, 1 enabling current path, test pulse filter, plug-in Push-in terminal block, wid
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2702523 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Utilization restriction Use in potentially explosive areas is not permitted in China.
- Depth 114.5 mm
- Air pressure (operation) 79 kPa ... 106 kPa
- Power consumption at US typ. 2 W (at US/UD; On state)
- Diagnostic supply voltage UD 24 V DC -20 % / +25 %
- Power consumption at UD typ. 0.9 W (at UD; Off state)
- Ambient temperature (operation) -25 °C ... 60 °C (observe derating)
- Maximum altitude ≤ 2000 m (Above sea level)
- Rated control supply current IS typ. 75 mA
- Input current at UD 35 mA (at UD = 24 V)
- Output name Signaling current path
- Contact type 1 signaling current path
- Diagnostic threshold 7 Ω ... 20 kΩ (configurable)
- Net weight 147.48 g
- Assembly instructions See derating curve
- Housing material Frianyl A 63 R V0
- Conductor cross-section flexible with ferrule without plastic sleeve 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
- Rated insulation voltage 250 V AC
- Degree of pollution 2
- Environmental simulation test ISA-S71.04 (G3)
- ECLASS 10.0.1 27371819
- ETIM 7.0 EC001449
- Width 17.5 mm
- Max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing)
- Air pressure (storage/transport) 79 kPa ... 106 kPa
- Inrush current max. 800 mA (Δt 100 ms)
- Protective circuit Surge protection 36 V suppressor diode (A1-A2)33 V suppressor diode (24V-GND)
- Inrush current at UD 1.5 A (Δt < 10 µs)
- Type of protection Surge protection
- Contact material AgNi, gold-flashed, Ag alloy
- Switching capacity min. 1 W
- Typical pickup time at US typ. 100 ms (when controlled via A1-A2)
- Degree of protection IP20
- Housing color yellow
- Status display 1 x yellow LED, 1 x green LED, 1 x red LED
- Safety Integrity Level (SIL) 3 (Reference IEC 61508)
- Standards/regulations DIN EN 50178
- Vibration (operation) 10 Hz ... 150 Hz, 2g
- ECLASS 9.0 27371819
- Ambient temperature (storage/transport) -40 °C ... 65 °C
- Rated control circuit supply voltage US 24 V DC -15 % / +10 %
- Filter time 2 ms (at A1-A2 in the event of voltage dips at Us)
- Number of inputs 3
- Number of outputs 1 (without delay, floating)
- Limiting continuous current 3 A (Observe derating, load type, and on-load voltage)
- Switching frequency max. 0.5 Hz
- Nominal operating mode 100% operating factor
- Mounting position vertical or horizontal
- pluggable Yes
- Conductor cross section flexible 0.2 mm² ... 1.5 mm²
- Stripping length 8 mm
- Rated surge voltage/insulation Basic insulation 4 kV between all current paths and housing
- REACh SVHC Lead 7439-92-1
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 6.0 27371800
- Height 117.4 mm
- Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing)
- Description of the input Test point for proof test
- Output description non-safety-related N/C contact
- Switching voltage min. 16 V AC/DC
- Mechanical service life approx. 5x 107 cycles
- Recovery time 1 s (when controlled via A1-A2)
- Mounting type DIN rail mounting
- Min. degree of protection of inst. location IP54
- Conductor cross-section AWG 24 ... 16
- Conductor cross-section flexible with ferrule and plastic sleeve 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
- Overvoltage category III
- ECLASS 11.0 27371819
- ECLASS 7.0 27371819
- Current consumption typ. 20 mA (Input TP1)
- Protective circuit/component 36 V suppressor diode
- Sq. Total current 9 A2 (observe derating)
- Typical release time at US typ. 30 ms (when controlled via A1-A2)
- Short-circuit protection no
- Relay type Electromechanical relay
- Connection method Push-in connection
- Conductor cross section solid 0.2 mm² ... 1.5 mm²
- Designation Air clearances and creepage distances between the power circuits
- Shock 15g, 11 ms
- Conformance CE-compliant
- ECLASS 5.1 27371901
- ETIM 6.0 EC001449
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.