2702524 Phoenix Contact Electrical Safety Devices
Part#:2702524
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
Coupling relay for SIL 3 high and low-demand applications, couples digital output signals to the I/O, 1 enabling current path, 1 confirmation current path, safe state off applications, test pulse filter, fixed screw terminal block
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2702524 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Width 6.8 mm
- Max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing)
- Input current range "0" signal 0 mA ... 2 mA (for safe Off)
- Protective circuit Serial protection against polarity reversal 33 V suppressor diode (A1-A2)33 V suppressor diode (21/0V)
- Contact type 1 confirmation current path
- Switching frequency max. 1 Hz
- Switching capacity according to IEC 60947-5-1 4 A (24 V (DC13))
- Recovery time 500 ms
- Net weight 71.494 g
- Housing material PBT
- Status display 2 x green LEDs
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Safety Integrity Level (SIL) 3 (Reference IEC 61508)
- Rated surge voltage/insulation Basic insulation 4 kV between all current paths and housing
- Depth 102.5 mm
- Maximum altitude ≤ 2000 m (Above sea level)
- Diagnostic supply voltage UD 24 V DC -15 % / +10 % (21/0V)
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Torque 0.5 Nm ... 0.6 Nm
- Overvoltage category III
- Conformance CE-compliant
- UL, USA/Canada cULus
- ECLASS 6.0 27371800
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Ambient temperature (operation) -40 °C ... 70 °C (observe derating)
- Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing)
- Power consumption at US typ. 1.08 W
- Input current at UD 6 mA (at the contacts 21/0V for UD; + 100 mA depending on load at contact 22)
- Output name Confirmation current path
- Limiting continuous current 100 mA
- Switching capacity min. 20 mW
- Output voltage Output of diagnostic supply voltage at contact 22: UD - 1.6 V
- Relay type Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
- Mounting type DIN rail mounting
- Housing color yellow
- Operating voltage display 1 x yellow LED
- Screw thread M3
- Designation Air clearances and creepage distances between the power circuits
- Degree of pollution 2
- Vibration (operation) 10 Hz ... 150 Hz, 2g
- Height 93.1 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Input voltage range "0" signal 0 V DC ... 5 V DC (for safe Off)
- Rated control supply current IS typ. 45 mA
- Inrush current at UD typ. 200 mA (Δt < 1 ms; for contacts 21 - 0 V at UD)
- Output description 2 N/C contacts in series, without delay, not floating (reference ground: A2)
- Contact material AgCuNi, + Au
- Sq. Total current 36 A2 (observe derating)
- Typical release time at US < 30 ms (when controlled via A1)
- Typical pickup time at US < 150 ms (with Us when controlled via A1)
- Nominal operating mode 100% operating factor
- Assembly instructions See derating curve
- Degree of protection IP20
- Connection method Screw connection
- Conductor cross-section AWG 24 ... 12
- Stripping length 12 mm
- Stop category 0
- Rated insulation voltage 250 V AC
- Environmental simulation test ISA-S71.04 (G3)
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 9.0 27371819
- Rated control circuit supply voltage US 24 V DC -15 % / +10 % (A1/A2)
- Inrush current min. 1 mA
- Filter time max. 3 ms (at A1-A2 in the event of voltage dips at Us)
- Number of outputs 1 (safety-related N/C contacts: 21/22)
- Switching voltage min. 20.4 V DC
- Mechanical service life 10x 106 cycles
- Output fuse 150 mA Fast-blow
- Mounting position vertical or horizontal
- Min. degree of protection of inst. location IP54
- Indication 1 x red LED
- pluggable no
- Standards/regulations DIN EN 50178, EN 60079-15
- IECEx Ex nA nC IIC T4 Gc
- ECLASS 11.0 27371819
- ETIM 7.0 EC001449
- Shock 15g
- REACh SVHC Lead 7439-92-1
- ECLASS 5.1 27371901
- ETIM 6.0 EC001449
- ATEX II 3 G Ex nA nC IIC T4 Gc
- ECLASS 10.0.1 27371819
- ECLASS 7.0 27371819
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨