Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e in accordance with EN ISO 13849, 1- or 2-channel operation, 3 enabling current paths, nominal input voltage: 120 V AC/DC, pluggable Push-in terminal block
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2901425 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Depth 114.5 mm
- Maximum altitude ≤ 2000 m (Above sea level)
- Typical release time 60 ms (when controlled via A1)
- Protective circuit Surge protection Varistor 275 VRMS (A1-A2)
- Maximum switching voltage 250 V AC/DC
- Inrush current, minimum 10 mA
- Maximum interrupting rating (inductive load) 48 W (24 V DC, τ = 40 ms)
- Switching capacity (360/h cycles) 6 A (24 V DC)
- Nominal operating mode 100% operating factor
- Width 22.5 mm
- Max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing)
- Voltage at input/start and feedback circuit ~ 24 V DC
- Status display Green LED
- Max. permissible overall conductor resistance 50 Ω
- Minimum switching voltage 10 V AC/DC
- Switching capacity min. 100 mW
- Mechanical service life approx. 107 cycles
- Net weight 175.62 g
- Mounting type DIN rail mounting
- pluggable Yes
- Conductor cross section flexible 0.2 mm² ... 1.5 mm²
- Performance level (PL) e
- Rated insulation voltage 250 V AC
- Vibration (operation) 10 Hz ... 150 Hz, 2g
- ECLASS 5.0 27371900
- ECLASS 9.0 27371819
- UNSPSC 6.01 30211901
- UNSPSC 18.0 39122205
- UNSPSC 20.0 39122205
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing)
- Input voltage range in reference to UN 0.85 ... 1.1
- Typ. starting time with Us 330 ms (when controlled via A1)
- Operating voltage display Green LED
- Contact material AgSnO2, + 0.2 µm Au
- Limiting continuous current 6 A (N/O contact)
- Interrupting rating (ohmic load) max. 144 W (24 V DC, τ = 0 ms)
- Mounting position any
- Conductor cross-section flexible with ferrule and plastic sleeve 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
- Designation Air clearances and creepage distances between the power circuits
- Safety Integrity Level Claim Limit (SIL CL) 3
- Rated surge voltage/insulation 4 kV / basic insulation (safe isolation, reinforced insulation, and 6 kV between A1-A2/logic/enabling and signaling current paths)
- ECLASS 10.0.1 27371819
- ECLASS 6.0 27371800
- ETIM 7.0 EC001449
- UNSPSC 7.0901 39121501
- Height 112 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Input voltage range 110 V AC/DC ... 120 V AC/DC
- Typical response time 40 ms (man. start)
- Concurrence ∞
- Maximum switching frequency 0.5 Hz
- Stop category 0
- Category 4
- REACh SVHC Lead 7439-92-1
- ECLASS 11.0 27371819
- ETIM 3.0 EC001449
- UNSPSC 11 39121501
- Ambient temperature (operation) -25 °C ... 55 °C
- Typical input current at UN 38 mA
- Recovery time 1 s
- Contact type 3 enabling current paths
- Maximum inrush current 6 A
- Sq. Total current 72 A2
- Output fuse 10 A gL/gG NEOZED (N/O contact)
- Relay type Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
- Degree of protection IP20
- Connection method Push-in connection
- Conductor cross section solid 0.2 mm² ... 1.5 mm²
- Stripping length 8 mm
- Safety Integrity Level (SIL) 3
- Overvoltage category III
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 5.1 27371900
- ECLASS 7.0 27371819
- ETIM 4.0 EC001449
- UNSPSC 13.2 39121501
- UNSPSC 21.0 39122205
- Min. degree of protection of inst. location IP54
- Conductor cross-section AWG 24 ... 16
- Conductor cross-section flexible with ferrule without plastic sleeve 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
- Standards/regulations DIN EN 50178/VDE 0160
- Degree of pollution 2
- Shock 15g
- ECLASS 4.0 40020600
- ECLASS 4.1 40020600
- ETIM 6.0 EC001449
- UNSPSC 12.01 39121501
- UNSPSC 19.0 39122205
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨