Phoenix Contact 2906059 Hybrid motor starter for reversing 3~ AC motors up to 550 V AC, with 24 V DC input, 2.4 A output current, emergency stop function, adjustable overload shutdown, higher transient voltage strength, and push-in connection.
Phoenix Contact

Part#:2906059

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 43

Dec 22, 2024

Hybrid motor starter for reversing 3~ AC motors up to 550 V AC, with 24 V DC input, 2.4 A output current, emergency stop function, adjustable overload shutdown, higher transient voltage strength, and push-in connection.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2906059 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Ambient temperature (operation)
    5 °C ... 70 °C (observe derating)
  • Rated control circuit supply voltage US
    24 V DC
  • Rated actuating voltage UC
    24 V DC
  • Switching threshold
    9.6 V (“0” signal)
  • Load current range
    180 mA ... 2.4 A (see to derating)
  • Contact type
    1 changeover contact
  • Switching frequency
    ≤ 2 Hz (Load-dependent)
  • Operating mode
    100% operating factor
  • Status display
    Yellow LED
  • Operating voltage display
    Green LED
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Rated surge voltage
    6 kV
  • Degree of pollution
    2
  • Insulation
    Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
  • FLA
    2.4 A (480 V AC)
  • Width
    22.5 mm
  • Type of protection
    Surge protection
  • Output name
    Acknowledge output
  • Rated operating current Ie
    2.4 A (AC-51)
  • Note
    Confirmation: floating change-over contact, signal contact
  • Motor starter type
    Reversing starter
  • Minimum power dissipation
    1.1 W
  • Indication
    Red LED
  • ECLASS 7.0
    27024002
  • ETIM 7.0
    EC001037
  • Depth
    114 mm
  • Degree of protection
    IP20
  • Triggering voltage range
    19.2 V DC ... 30 V DC
  • Typical turn-off time
    < 30 ms
  • Trigger characteristic in acc. with IEC 60947-4-2
    Class 10A
  • SCCR
    100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))
  • Group installation
    20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
  • ECLASS 11.0
    27370905
  • ECLASS 5.0
    27024000
  • UNSPSC 13.2
    25173902
  • UNSPSC 19.0
    25173902
  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C
  • Control supply voltage range
    19.2 V DC ... 30 V DC
  • Rated actuating current IC
    5 mA
  • Rated operating voltage Ue
    500 V AC
  • Mains frequency
    50/60 Hz
  • Leakage current
    0 mA
  • Mounting type
    DIN rail mounting
  • Assembly instructions
    alignable, for spacing see derating
  • Connection method
    Push-in connection
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Rated insulation voltage
    500 V
  • Designation
    Category (ISO 13849)
  • Standards/regulations
    IEC 60947-1
  • Additional text
    Safe shutdown
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.0
    27021100
  • ECLASS 6.0
    27024000
  • ECLASS 9.0
    27370905
  • ETIM 4.0
    EC001037
  • UNSPSC 18.0
    25173902
  • UNSPSC 20.0
    25173902
  • Height
    107.5 mm
  • Maximum altitude
    ≤ 2000 m
  • Input name
    Control input right/left
  • Rated control supply current IS
    40 mA
  • Switching level
    < 5 V DC (For EMERGENCY STOP)
  • Operating voltage range
    42 V AC ... 550 V AC
  • Cooling time
    20 min.
  • Switching capacity according to IEC 60947-5-1
    3 A (230 V, AC15)
  • Mounting position
    vertical (horizontal DIN rail, motor output below)
  • Maximum power dissipation
    3.3 W
  • Connection name
    Load circuit
  • Stripping length
    10 mm
  • Conductor cross section AWG
    24 ... 14
  • Overvoltage category
    III
  • Certificate
    NLDX.E228652
  • Identification
    ≤ 3
  • Category code
    NLDX / NRNT
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 10.0.1
    27370905
  • ECLASS 5.1
    27024000
  • ECLASS 4.1
    27021100
  • ETIM 3.0
    EC001037
  • ETIM 2.0
    EC001037
  • ETIM 6.0
    EC001037
  • UNSPSC 21.0
    25173902

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$279.71

Stock:

43

Select Qty:

$279.71

$279.71 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo