2909557 Phoenix Contact Electrical Safety Devices

Phoenix Contact 2909557 Hybrid motor starter as an alternative to a conventional protective circuit. Starts 3~ AC motors up to 3 A, provides motor protection, ATEX, and emergency stop up to SIL 3. Group shut-down, supply, and relay extension possible via DIN rail connector.
Phoenix Contact

Part#:2909557

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Hybrid motor starter as an alternative to a conventional protective circuit. Starts 3~ AC motors up to 3 A, provides motor protection, ATEX, and emergency stop up to SIL 3. Group shut-down, supply, and relay extension possible via DIN rail connector.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2909557 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Maximum altitude
    ≤ 2000 m
  • Ambient temperature (operation)
    -25 °C ... 55 °C
  • Rated control supply current IS
    60 mA
  • Switching level
    < 5 V DC (For EMERGENCY STOP)
  • Rated operating current Ie
    3 A (AC-51)
  • Contact type
    1 changeover contact
  • Switching capacity according to IEC 60947-5-1
    2 A (24 V, DC13)
  • Mounting type
    DIN rail mounting
  • Maximum power dissipation
    4.1 W
  • Indication
    Red LED
  • Conductor cross section AWG
    24 ... 14
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Degree of pollution
    2
  • Identification
    ≤ 3
  • Additional text
    Safe shutdown
  • Horsepower ratings
    0.5 hp (208 V AC)
  • ECLASS 4.1
    27021100
  • ECLASS 7.0
    27024002
  • ETIM 4.0
    EC001037
  • Depth
    114 mm
  • Control supply voltage range
    19.2 V DC ... 30 V DC
  • Triggering voltage range
    19.2 V DC ... 30 V DC
  • Output name
    Acknowledge output
  • Load current range
    180 mA ... 3 A
  • Leakage current
    0 mA
  • Response time
    < 0.5 s
  • Minimum power dissipation
    0.88 W
  • Status display
    Yellow LED
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Insulation
    Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
  • Certificate
    NLDX.E228652
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.0
    27021100
  • ECLASS 9.0
    27370905
  • ETIM 6.0
    EC001037
  • Width
    22.5 mm
  • Degree of protection
    IP20
  • Type of protection
    Surge protection
  • Rated actuating voltage UC
    24 V DC
  • Rated operating voltage Ue
    500 V AC
  • Operating voltage range
    42 V AC ... 550 V AC
  • Cooling time
    20 min. (for auto reset)
  • Operate threshold
    > 33 A
  • Mounting position
    vertical (horizontal DIN rail, motor output below)
  • Operating voltage display
    Green LED
  • Stripping length
    10 mm
  • Rated surge voltage
    6 kV
  • Standards/regulations
    EN 60947-1
  • Category code
    NLDX / NRNT
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 6.0
    27024000
  • ETIM 3.0
    EC001037
  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C
  • Note
    Confirmation: floating change-over contact, signal contact
  • Switching threshold
    9.6 V (“0” signal)
  • Mains frequency
    50/60 Hz
  • Trigger characteristic in acc. with IEC 60947-4-2
    Class 10
  • Switching frequency
    ≤ 2 Hz (Load-dependent)
  • Assembly instructions
    alignable, for spacing see derating
  • Operating mode
    100% operating factor
  • Connection name
    Load circuit
  • Connection method
    Push-in connection
  • Overvoltage category
    III
  • SCCR
    100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))
  • FLA
    3 A (480 V AC)
  • ECLASS 10.0.1
    27370905
  • ECLASS 11.0
    27370905
  • ETIM 2.0
    EC001037
  • ETIM 7.0
    EC001037
  • Height
    107.5 mm
  • Rated control circuit supply voltage US
    24 V DC
  • Input name
    Control input and enable input
  • Rated actuating current IC
    7 mA
  • Typical turn-off time
    < 30 ms
  • Rated insulation voltage
    550 V
  • Designation
    Category (ISO 13849)
  • Group installation
    20 A (class RK5, SCCR 5kA (480 V AC), #24 - 14 AWG max. solid and stranded)
  • ECLASS 5.0
    27024000
  • ECLASS 5.1
    27024000

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo