2910119 Phoenix Contact DC/DC Converters
Part#:2910119
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 35
Dec 22, 2024
Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, SFB Technology (Selective Fuse Breaking), Push-in connection, input: 24 V DC , output: 24 V DC / 5 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2910119 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Weight0.6 kg
- Output current 5 A
- Main converter stage 50 kHz ... 420 kHz (Main converter stage)
- Hood version Stainless steel X6Cr17
- Height with alternative assembly 130 mm
- Power dissipation SLEEP MODE < 1 W
- Ambient temperature (start-up type tested) -40 °C
- Maximum altitude ≤ 5000 m (> 2000 m, observe derating)
- Climatic class 3K3 (EN 60721)
- Overvoltage category EN 61010-1 II
- Identification ABS
- Noise emission EN 55016
- Electromagnetic HF field EN 61000-4-3
- Fast transients (burst) EN 61000-4-4
- Surge voltage load (surge) EN 61000-4-5
- Frequency 0 Hz
- Electric strength, max. 35 V DC (60 s)
- Mains buffering typ. 14 ms (24 V DC)
- Typical response time 300 ms (from SLEEP MODE)
- Input fuse 15 A (slow-blow, internal)
- Insulation voltage input/output 4 kV DC (type test)
- Type test (IEC/EN 60950-1) C 0.5 kV DC
- Production test A 2 kV DC
- Production test D 0.5 kV DC
- Conductor cross section flexible 0.2 mm² ... 1.5 mm²
- Flexible conductor cross section (ferrule with plastic sleeve) 0.2 mm² ... 0.75 mm²
- Static Boost (IStat.Boost) 6.25 A
- Selective Fuse Breaking (ISFB) 30 A (15 ms)
- No-load proof yes
- Protection against overvoltage at the output (OVP) ≤ 32 V DC
- Types of signaling LED
- Connection labeling 3.4 +
- Analog 4 mA ... 20 mA ±5 % (Load ≤400 Ω)
- Function Signal ground
- Auxiliary converter stage 190 kHz ... 220 kHz (Auxiliary converter stage)
- Degree of protection IP20
- Depth 125 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Power loss nominal load max. < 10 W
- Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
- EMC requirements, power plant IEC 61850-3
- Designation Shipbuilding
- DNV GL noise radiation Class B
- Additional text Test Level 2
- Discharge in air 15 kV (Test Level 4)
- Output 1 kV (Test Level 3 - symmetrical)
- Power frequency magnetic field EN 61000-4-8
- Test level 2 150 Hz 1.5 kHz (Test Level 3)
- Alternating component of DC voltage EN 61000-4-17
- Signals (test level 1) 100 kHz 1 MHz (Test Level 2 - symmetrical)
- ECLASS 11.0 27210901
- Magnetic circuit breaker tripping A1 ... A4 / B2 / C1 ... C2 / Z1 ... Z4
- Short-circuit-proof yes
- Connection in parallel Yes, for redundancy and increased capacity
- Rise time < 1 s (UOUT (10 % ... 90 %))
- UOut > 0.9 x USet (LED lights up green)
- Default Output power ON (>40 kΩ/24 V DC/open bridge between REM and SGnd)
- Digital 0 V DC
- Maximum contact load 24 V DC
- Temperature 30 °C
- Time 520000 h
- Width 36 mm
- Depth with alternative assembly 39 mm
- Maximum power dissipation in no-load condition < 2 W
- Vibration (operation) 5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)
- EMC requirements for noise immunity EN 61000-6-1
- EMC requirements for noise emission EN 61000-6-3
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- DNV GL conducted interference Class B
- Frequency range 50 Hz ... 60 Hz
- Comments Criterion A
- I/O/S asymmetrical
- Voltage dip 0 %
- Input, output (test level 1) 100 kHz 1 MHz (Test Level 3 - symmetrical)
- Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
- ETIM 7.0 EC002046
- Input voltage range 18 V DC ... 32 V DC
- Typical current consumption 6.9 A (24 V DC)
- Switch-on time < 1 s
- Inrush current limitation typical 1 A
- Inrush current integral (I2t) < 0.05 A2s
- Type test (IEC/EN 60950-1) D 0.5 kV DC
- Production test C 0.5 kV DC
- Connection method Push-in connection
- Conductor cross section solid 0.2 mm² ... 1 mm²
- Conductor cross section AWG 24 ... 16
- Nominal output current (IN) 5 A
- Dynamic Boost (IDyn.Boost) 10 A (5 s)
- System deviation, dynamic < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
- Residual ripple < 10 mVPP
- UIn > 0.8 x UInNom (LED off)
- Switch contact floating
- Reference potential to OUT1, OUT2, REM
- Side element version Aluminum
- Width with alternative assembly 122 mm
- Efficiency typ. 92.2 % (24 V DC)
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Overvoltage category EN 62477-1 III
- Standard designation Mains variation/undervoltage
- Conducted noise emission EN 55016
- Electrostatic discharge EN 61000-4-2
- Input 1 kV (Test Level 3 - symmetrical)
- Conducted interference EN 61000-4-6
- Pulse-shape magnetic field EN 61000-4-9
- Asymmetrical conducted disturbance variables EN 61000-4-16
- Test level 6 0 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3)
- Attenuated oscillating wave EN 61000-4-18
- ECLASS 10.0.1 27210901
- ETIM 6.0 EC002046
- Type test (IEC/EN 60950-1) A 2 kV DC
- Type test (IEC/EN 60950-1) B 4 kV DC
- Production test B 2 kV DC
- Stripping length 8 mm
- Flexible conductor cross section flexible (ferrule, w/o plastic sleeve) 0.2 mm² ... 1.5 mm²
- Nominal output voltage (UN) 24 V DC
- Setting range of the output voltage (USet) 24 V DC ... 29.5 V DC (> 24 V DC, constant capacity)
- System deviation, static < 1 % (change in load, static 10 % ... 90 %)
- System deviation, input voltage change < 0.1 % (change in input voltage ±10 %)
- Connection in series yes
- Feedback voltage resistance ≤ 35 V DC
- POut > 100 % (LED lights up yellow, output power > 120 W)
- Signal option Output current
- MTBF (IEC 61709, SN 29500) > 1600000 h (25 °C)
- Voltage 1 kV
- Protection class Special with SELV input and output
- Height 130 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Degree of pollution 2
- Standards/regulations EN 61000-4-29
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Contact discharge 8 kV (Test Level 4)
- Test field strength 100 A/m
- Signal 2 kV (Test Level 3 - asymmetrical)
- Voltage dips EN 61000-4-29
- Test level 1 15 Hz 150 Hz (Test Level 3)
- Test level 4 15 kHz 150 kHz (Test Level 3)
- Input, output (test level 3) 10 MHz (Test Level 2 - asymmetrical)
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 9.0 27210901
- Damped oscillating magnetic field EN 61000-4-10
- Test level 3 1.5 kHz 15 kHz (Test Level 3)
- Test level 5 16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
- Input, output (test level 2) 100 kHz 1 MHz (Test Level 2 - asymmetrical)
- Signals (test level 2) 100 kHz 1 MHz (Test Level 2 - asymmetrical)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$230.33
Stock:
35
Select Qty:
$230.33
$230.33 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨