Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, SFB Technology (Selective Fuse Breaking), Push-in connection, input: 24 V DC , output: 12 V DC / 8 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2910122 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Weight0.6 kg
- Degree of pollution 2
- Mains buffering typ. 17 ms (24 V DC)
- Input fuse 15 A (slow-blow, internal)
- Type test (IEC/EN 60950-1) B 4 kV DC
- Type test (IEC/EN 60950-1) C 0.5 kV DC
- Production test C 0.5 kV DC
- Conductor cross section flexible 0.2 mm² ... 1.5 mm²
- Nominal output voltage (UN) 12 V DC
- Selective Fuse Breaking (ISFB) 48 A (15 ms)
- System deviation, dynamic < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
- Residual ripple < 13 mVPP
- Protection against overvoltage at the output (OVP) ≤ 18 V DC
- Connection labeling 3.4 +
- Maximum contact load 24 V DC
- Reference potential to OUT1, OUT2, REM
- Degree of protection IP20
- Side element version Aluminum
- Depth 125 mm
- Ambient temperature (start-up type tested) -40 °C
- Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
- Electric strength, max. 35 V DC (60 s)
- Switch-on time < 1 s
- Insulation voltage input/output 4 kV DC (type test)
- Connection method Push-in connection
- Stripping length 8 mm
- Conductor cross section AWG 24 ... 16
- Magnetic circuit breaker tripping A1 ... A6 / B2 ... B6 / Z1 ... Z6
- Short-circuit-proof yes
- Connection in series yes
- UIn > 0.8 x UInNom (LED off)
- Digital 0 V DC
- Output current 8 A
- Time 422000 h
- Protection class Special with SELV input and output
- Width 36 mm
- Height 130 mm
- Depth with alternative assembly 39 mm
- Power dissipation SLEEP MODE < 1 W
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Overvoltage category EN 61010-1 II
- Overvoltage category EN 62477-1 III
- Identification ABS
- Conducted noise emission EN 55016
- DNV GL noise radiation Class B
- Contact discharge 8 kV (Test Level 4)
- Comments Criterion A
- Fast transients (burst) EN 61000-4-4
- Conducted interference EN 61000-4-6
- Voltage dip 0 %
- Pulse-shape magnetic field EN 61000-4-9
- Asymmetrical conducted disturbance variables EN 61000-4-16
- Attenuated oscillating wave EN 61000-4-18
- ECLASS 10.0.1 27210901
- ECLASS 9.0 27210901
- ETIM 7.0 EC002046
- Typical current consumption 5.5 A (24 V DC)
- Typical response time 300 ms (from SLEEP MODE)
- Inrush current integral (I2t) < 0.02 A2s
- Type test (IEC/EN 60950-1) A 2 kV DC
- Production test B 2 kV DC
- Conductor cross section solid 0.2 mm² ... 1 mm²
- Flexible conductor cross section (ferrule with plastic sleeve) 0.2 mm² ... 0.75 mm²
- Nominal output current (IN) 8 A
- System deviation, static < 1 % (change in load, static 10 % ... 90 %)
- No-load proof yes
- Types of signaling LED
- Default Output power ON (>40 kΩ/24 V DC/open bridge between REM and SGnd)
- Switch contact floating
- MTBF (IEC 61709, SN 29500) > (25 °C)
- Voltage 1 kV
- Main converter stage 50 kHz ... 350 kHz (Main converter stage)
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Width with alternative assembly 122 mm
- Maximum power dissipation in no-load condition < 2 W
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Climatic class 3K3 (EN 60721)
- EMC requirements for noise immunity EN 61000-6-1
- Designation Shipbuilding
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- DNV GL conducted interference Class B
- Electromagnetic HF field EN 61000-4-3
- Test field strength 100 A/m
- Signal 2 kV (Test Level 3 - asymmetrical)
- I/O/S asymmetrical
- Voltage dips EN 61000-4-29
- Test level 1 15 Hz 150 Hz (Test Level 3)
- Test level 4 15 kHz 150 kHz (Test Level 3)
- Test level 6 0 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3)
- Input, output (test level 1) 100 kHz 1 MHz (Test Level 3 - symmetrical)
- Signals (test level 1) 100 kHz 1 MHz (Test Level 2 - symmetrical)
- Signals (test level 2) 100 kHz 1 MHz (Test Level 2 - asymmetrical)
- Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
- Setting range of the output voltage (USet) 12 V DC ... 15 V DC (> 12 V DC, constant capacity)
- System deviation, input voltage change < 0.1 % (change in input voltage ±10 %)
- Feedback voltage resistance ≤ 25 V DC
- Rise time < 1 s (UOUT (10 % ... 90 %))
- POut > 100 % (LED lights up yellow, output power > 96 W)
- Analog 4 mA ... 20 mA ±5 % (Load ≤400 Ω)
- Input voltage range 18 V DC ... 32 V DC
- Inrush current limitation typical 1 A
- Type test (IEC/EN 60950-1) D 0.5 kV DC
- Production test A 2 kV DC
- Production test D 0.5 kV DC
- Flexible conductor cross section flexible (ferrule, w/o plastic sleeve) 0.2 mm² ... 1.5 mm²
- Static Boost (IStat.Boost) 10 A
- Dynamic Boost (IDyn.Boost) 16 A (5 s)
- Connection in parallel Yes, for redundancy and increased capacity
- UOut > 0.9 x USet (LED lights up green)
- Signal option Output current
- Function Signal ground
- Temperature 30 °C
- Auxiliary converter stage 190 kHz ... 220 kHz (Auxiliary converter stage)
- Hood version Stainless steel X6Cr17
- Height with alternative assembly 130 mm
- Efficiency typ. 91 % (24 V DC)
- Power loss nominal load max. < 9 W
- Maximum altitude ≤ 5000 m (> 2000 m, observe derating)
- Vibration (operation) 5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)
- EMC requirements, power plant IEC 61850-3
- Standard designation Mains variation/undervoltage
- Noise emission EN 55016
- Electrostatic discharge EN 61000-4-2
- Frequency range 50 Hz ... 60 Hz
- Output 1 kV (Test Level 3 - symmetrical)
- Power frequency magnetic field EN 61000-4-8
- Damped oscillating magnetic field EN 61000-4-10
- Test level 3 1.5 kHz 15 kHz (Test Level 3)
- Test level 5 16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
- Input, output (test level 3) 10 MHz (Test Level 2 - asymmetrical)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ETIM 6.0 EC002046
- EMC requirements for noise emission EN 61000-6-3
- Standards/regulations EN 61000-4-29
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Additional text Test Level 2
- Discharge in air 15 kV (Test Level 4)
- Input 1 kV (Test Level 3 - symmetrical)
- Surge voltage load (surge) EN 61000-4-5
- Frequency 0 Hz
- Test level 2 150 Hz 1.5 kHz (Test Level 3)
- Alternating component of DC voltage EN 61000-4-17
- Input, output (test level 2) 100 kHz 1 MHz (Test Level 2 - asymmetrical)
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 11.0 27210901
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$274.47
Stock:
43
Select Qty:
$274.47
$274.47 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.