3000564 Phoenix Contact Terminal Blocks
Part#:3000564
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 50
Dec 22, 2024
Lever-type disconnect terminal block, nom. voltage: 500 V, nominal current: 16 A, connection method: Screw connection, cross section: 0.5 mm² - 6 mm², AWG: 20 - 10, length: 58 mm, width: 8.2 mm, color: black/orange, mounting: NS 35/7,5, NS 35/15, NS 32
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3000564 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Number of connections 2
- Color black/orange
- Insulating material group I
- Nominal current IN 16 A
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Bending test conductor cross section/weight 0.5 mm² / 0.3 kg
- Short circuit stability result Test passed
- Short-time current 0.18 kA
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Conductor cross section solid min. 0.5 mm²
- Height NS 32 55 mm
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.5 mm²
- 2 conductors with same cross section, stranded min. 0.5 mm²
- Connection method Screw connection
- Tightening torque max 0.8 Nm
- REACh SVHC Lead 7439-92-1
- ECLASS 4.0 27141100
- ECLASS 7.0 27141126
- ETIM 7.0 EC000902
- UNSPSC 18.0 39121410
- UNSPSC 21.0 39121410
- Insulating material PA
- Degree of pollution 3
- Connection in acc. with standard IEC 60947-7-1
- Back of the hand protection guaranteed
- Power frequency withstand voltage setpoint 1.89 kV
- Bending test turns 135
- Bending test rotation speed 10 (+/- 2) rpm
- Setpoint 1 N
- Result of temperature-rise test Test passed
- Test spectrum Service life test category 2, bogie-mounted
- Shock form Semi-sinusoidal
- Surface flammability NFPA 130 (ASTM E 162) passed
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Width 8.2 mm
- Height NS 35/15 57.6 mm
- Conductor cross section flexible max. 4 mm²
- Conductor cross section AWG min. 20
- 2 conductors with same cross section, solid max. 1.5 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 0.5 mm²
- Stripping length 9 mm
- Ambient temperature (assembly) -5 °C ... 70 °C
- Permissible humidity (storage/transport) 30 % ... 70 %
- ECLASS 5.1 27141100
- ETIM 3.0 EC000902
- UNSPSC 6.01 30211811
- UNSPSC 20.0 39121410
- Number of levels 1
- Overvoltage category III
- Nominal voltage UN 500 V
- Maximum power dissipation for nominal condition 1.02 W
- Surge voltage test setpoint 7.3 kV
- Result of flexion and pull-out test Test passed
- Tractive force setpoint 80 N
- Result of voltage-drop test Test passed
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Test frequency f1 = 5 Hz to f2 = 250 Hz
- Test duration per axis 5 h
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- End cover width 2.2 mm
- Conductor cross section solid max. 6 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve max. 4 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 1.5 mm²
- Screw thread M3
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- Ambient temperature (actuation) -5 °C ... 70 °C
- ECLASS 5.0 27141100
- ECLASS 6.0 27141100
- ETIM 6.0 EC000902
- UNSPSC 7.0901 39121410
- UNSPSC 19.0 39121410
- Nominal cross section 4 mm²
- Rated surge voltage 6 kV
- Maximum load current 16 A (with 4 mm² conductor cross section)
- Number of positions 1
- Result of surge voltage test Test passed
- Result of power-frequency withstand voltage test Test passed
- Tensile test result Test passed
- Tight fit on carrier NS 32/NS 35
- Conductor cross section short circuit testing 1.5 mm²
- Acceleration 30g
- Number of shocks per direction 3
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- Static insulating material application in cold -60 °C
- Length 58 mm
- Conductor cross section flexible min. 0.5 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.5 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve max. 2.5 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 1.5 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
- Cross section with insertion bridge, stranded max. 4 mm²
- Tightening torque, min 0.6 Nm
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 10.0.1 27141126
- ETIM 4.0 EC000902
- UNSPSC 11 39121410
- Flammability rating according to UL 94 V0
- Open side panel Yes
- Finger protection guaranteed
- Conductor cross section tensile test 6 mm²
- Requirements, voltage drop ≤ 3.2 mV
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2018-05
- ASD level 6.12 (m/s2)2/Hz
- Shock duration 18 ms
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Height NS 35/7,5 50 mm
- Conductor cross section AWG max. 10
- 2 conductors with same cross section, solid min. 0.5 mm²
- 2 conductors with same cross section, stranded max. 1.5 mm²
- Cross section with insertion bridge, solid max. 4 mm²
- Internal cylindrical gage A4
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ECLASS 11.0 27141126
- ECLASS 4.1 27141100
- ECLASS 9.0 27141126
- UNSPSC 12.01 39121410
- UNSPSC 13.2 39121410
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$12.82
Stock:
50
Select Qty:
$12.82
$12.82 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨