3059265 Phoenix Contact Terminal Blocks
Part#:3059265
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 48
Dec 23, 2024
Feed-through terminal block, With equipotential bonder, connection method: Screw connection, cross section: 0.14 mm² - 6 mm², AWG: 26 - 10, width: 6.2 mm, color: blue, mounting type: NS 35/7,5, NS 35/15
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3059265 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Color blue
- Overvoltage category III
- Maximum power dissipation for nominal condition 1.02 W (the value is multiplied when connecting multiple levels)
- Open side panel Yes
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 0.14 mm²
- Length 69.9 mm
- Conductor cross section flexible min. 0.14 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.14 mm²
- Stripping length 9 mm
- Conductor cross section AWG max. 10
- Internal cylindrical gage A4
- Permissible humidity (storage/transport) 30 % ... 70 %
- Insulating material PA
- Degree of pollution 3
- Connection in acc. with standard CSA
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- Nominal voltage UN 800 V
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Height NS 35/15 72.5 mm
- Conductor cross section solid max. 6 mm²
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- End cover width 2.2 mm
- Connection method Screw connection
- 2 conductors with same cross section, solid min. 0.14 mm²
- 2 conductors with same cross section, stranded max. 1.5 mm²
- Width 6.2 mm
- Conductor cross section solid min. 0.14 mm²
- 2 conductors with same cross section, stranded min. 0.14 mm²
- Conductor cross section flexible max. 6 mm²
- Screw thread M3
- Tightening torque, min 0.6 Nm
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- 2 conductors with same cross section, solid max. 1.5 mm²
- China RoHS Environmentally Friendly Use Period = 50 years
- ETIM 3.0 EC000897
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- ECLASS 4.0 27141100
- ECLASS 7.0 27141120
- ECLASS 10.0.1 27141120
- ECLASS 6.0 27141100
- ECLASS 5.1 27141100
- Tightening torque max 0.8 Nm
- Ambient temperature (assembly) -5 °C ... 70 °C
- UNSPSC 12.01 39121410
- ETIM 4.0 EC000897
- ETIM 6.0 EC000897
- UNSPSC 7.0901 39121410
- UNSPSC 18.0 39121410
- UNSPSC 19.0 39121410
- ECLASS 9.0 27141120
- UNSPSC 6.01 30211811
- UNSPSC 11 39121410
- UNSPSC 21.0 39121410
- ETIM 7.0 EC000897
- UNSPSC 13.2 39121410
- UNSPSC 20.0 39121410
- Nominal current IN 30 A
- Conductor cross section flexible, with ferrule without plastic sleeve max. 4 mm²
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Ambient temperature (actuation) -5 °C ... 70 °C
- ECLASS 5.0 27141100
- Conductor cross section flexible, with ferrule with plastic sleeve max. 4 mm²
- ECLASS 11.0 27141120
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 1.5 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.14 mm²
- ECLASS 4.1 27141100
- Insulating material group I
- Maximum load current 36 A (with 6 mm² conductor cross section)
- Static insulating material application in cold -60 °C
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Height NS 35/7,5 65 mm
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
- Relative insulation material temperature index (Elec.; UL 746 B) 130 °C
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Surface flammability NFPA 130 (ASTM E 162) passed
- Conductor cross section AWG min. 26
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 2.5 mm²
- Number of connections 4
- Rated surge voltage 8 kV
- Number of levels 2
- Flammability rating according to UL 94 V0
- Nominal cross section 4 mm²
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$8.91
Stock:
48
Select Qty:
$8.91
$8.91 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨