Component terminal block, with integrated 1N4007 diode, The max. current is determined by the diode. Installed: Diode 1N 4007, reverse voltage: 1300 V, maximum continuous current: 0.5 A., nom. voltage: 500 V, nominal current: 20 A, connection method: Push
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3215041 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Number of levels 2
- Color gray
- Rated surge voltage 6 kV
- Maximum load current 26 A (with 4 mm² conductor cross section, rigid)
- Result of surge voltage test Test passed
- Power frequency withstand voltage setpoint 1.89 kV
- Bending test turns 135
- Conductor cross section short circuit testing 4 mm²
- Result of aging test Test passed
- Result of thermal test Test passed
- Number of connections 4
- Nominal voltage UN 500 V
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2018-05
- Shock test result Test passed
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Height NS 35/7,5 47.5 mm
- Conductor cross section flexible min. 0.14 mm²
- Conductor cross section AWG max. 12
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.14 mm²
- REACh SVHC Lead 7439-92-1
- ECLASS 11.0 27141127
- ECLASS 5.1 27141100
- ETIM 6.0 EC000903
- UNSPSC 6.01 30211811
- UNSPSC 12.01 39121410
- UNSPSC 21.0 39121410
- Nominal cross section 2.5 mm²
- Overvoltage category III
- Open side panel Yes
- Test duration per axis 5 h
- Surface flammability NFPA 130 (ASTM E 162) passed
- Relative insulation material temperature index (Elec.; UL 746 B) 130 °C
- Static insulating material application in cold -60 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Height NS 35/15 55 mm
- Conductor cross section solid min. 0.14 mm²
- Conductor cross section AWG min. 26
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 0.5 mm²
- Stripping length 10 mm
- ECLASS 10.0.1 27141127
- ECLASS 9.0 27141127
- UNSPSC 7.0901 39121410
- UNSPSC 18.0 39121410
- Note The max. current is determined by the diode. Installed: Diode 1N 4007, reverse voltage: 1300 V, maximum continuous current: 0.5 A.
- Degree of pollution 3
- Flammability rating according to UL 94 V0
- Nominal current IN 20 A
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Back of the hand protection guaranteed
- Result of flexion and pull-out test Test passed
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Shock duration 18 ms
- Number of shocks per direction 3
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Width 5.2 mm
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Conductor cross section solid max. 4 mm²
- Conductor cross section flexible max. 4 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve max. 2.5 mm²
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 4.0 27141100
- ECLASS 4.1 27141100
- ETIM 4.0 EC000897
- UNSPSC 11 39121410
- UNSPSC 20.0 39121410
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2018-05
- Acceleration 30g
- Shock form Half-sine
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Length 68 mm
- End cover width 2.2 mm
- Connection method Push-in connection
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.14 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve max. 2.5 mm²
- Internal cylindrical gage A3
- ECLASS 6.0 27141100
- ECLASS 5.0 27141100
- ECLASS 7.0 27141120
- ETIM 7.0 EC000903
- UNSPSC 19.0 39121410
- UNSPSC 13.2 39121410
- Finger protection guaranteed
- Result of tight fit on support Test passed
- Ageing test for screwless modular terminal block temperature cycles 192
- Test frequency f1 = 5 Hz to f2 = 250 Hz
- Insulating material PA
- Result of power-frequency withstand voltage test Test passed
- Bending test rotation speed 10 rpm
- Short-time current 0.48 kA
- Oscillation, broadband noise test result Test passed
- Insulating material group I
- Surge voltage test setpoint 7.3 kV
- Bending test conductor cross section/weight 0.14 mm² / 0.2 kg
- Proof of thermal characteristics (needle flame) effective duration 30 s
- ASD level 6.12 (m/s2)2/Hz
- Maximum power dissipation for nominal condition 0.77 W (the value is multiplied when connecting multiple levels)
- Checking the mechanical stability of terminal points (5 x conductor connection) Test passed
- Tight fit on carrier NS 35
- Short circuit stability result Test passed
- Setpoint 1 N
- Test spectrum Service life test category 2, bogie-mounted
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨