PSC1-C-10-FB2 Schmersal Safety Controllers

Schmersal PSC1-C-10-FB2 PSC1-C-10-FB2 Schmersal - Safety controllers; PROTECT PSC1; Memory card; conversion of the field bus protocols by software; integrated SD-Bus-Gateway; Modular expansion with up to 64 inputs / outputs; 4 safe 2 A pp-switching semiconductor outputs, switchable to 2 safe p- / n-switc
Schmersal

Part#:PSC1-C-10-FB2

Manufacturer:Schmersal

Alt. Part#:103008442

Product Lifecycle:Active

Get a quick Quote!

PSC1-C-10-FB2 Schmersal - Safety controllers; PROTECT PSC1; Memory card; conversion of the field bus protocols by software; integrated SD-Bus-Gateway; Modular expansion with up to 64 inputs / outputs; 4 safe 2 A pp-switching semiconductor outputs, switchable to 2 safe p- / n-switc

About the manufacturer: Schmersal is one of the manufacturers that offers Safety Controllers that you can order at marketplace.quotebeam.com. Schmersal produces a wide range of high-quality switchgears specifically engineered to protect machinery and facilities in industrial automation and the elevator industry.

Check out the PSC1-C-10-FB2 Schmersal price in the box on the right side or send a quick quote.

Product Details

  • Electromagnetic compatibility
    DIN EN 62061, DIN EN 61800-3
  • Interfering radiation
    DIN EN 61000-6-4
  • EMC rating
    DIN EN 61000-6-7, DIN EN 61326-3, DIN EN 61000-6-2
  • Current, Utilisation category DC13
    2 A
  • Voltage, Utilisation category AC15
    230 VAC
  • Voltage, Utilisation category DC13
    24 VDC
  • Current, Utilisation category AC-15
    2 A
  • Versions
    short-circuit proof, p-type (Q2 und Q3)
  • Rated operating current (safety outputs)
    2,000 mA
  • Operating voltage, maximum
    28.8 VDC
  • Field bus
    CANopen, PROFIBUS
  • Zulässige Aufstellhöhe über NN, maximum
    2,000 m
  • Designation, Communication interface
    DSUB
  • Degree of pollution to IEC/EN 60664-1
    2
  • Operating voltage, minimum
    20.4 VDC
  • Overvoltage category
    III
  • Note (Relative humidity)
    non-condensing
  • Relative humidity, maximum
    85 %
  • Storage and transport temperature, maximum
    +70 °C
  • Relative humidity, minimum
    5 %
  • Storage and transport temperature, minimum
    -25 °C
  • Ambient temperature, minimum
    +0 °C
  • Degree of protection
    IP20
  • Ambient temperature, maximum
    +50 °C
  • Gross weight
    582.1 g
  • Depth
    115 mm
  • Height
    100 mm
  • Wire cross-section, maximum
    12 AWG
  • Width
    67.5 mm
  • Cable section, maximum
    2.5 mm²
  • Wire cross-section, minimum
    24 AWG
  • Cable section, minimum
    0.2 mm²
  • Mounting
    can be clipped into standard rail
  • Anzahl der Erweiterungsbaugruppen, maximal
    2
  • Integrated SD gateway
    Yes
  • Master-Slave-Kommunikation
    Yes
  • Terminal (mechanical)
    Removable screw terminals
  • SD Card Slot
    Yes
  • Number of signalling outputs
    2
  • Number of fail-safe digital outputs
    4
  • Master-Master-Kommunikation
    Yes
  • Number of digital fail-safe inputs
    14
  • Number of relay outputs (1-channel)
    2
  • Number of pulse outputs (test pulse output)
    2

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


PSC1-C-10-FB2 Description

PSC1-C-10-FB2 Schmersal - Safety controllers; PROTECT PSC1; Memory card; conversion of the field bus protocols by software; integrated SD-Bus-Gateway; Modular expansion with up to 64 inputs / outputs; 4 safe 2 A pp-switching semiconductor outputs, switchable to 2 safe p- / n-switc



Related documents PSC1-C-10-FB2 Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Schmersal

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Schmersal Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Schmersal Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Schmersal, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo