Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

ATV71HU30S6X Schneider Electric Variable Frequency Drives (VFD)

Schneider Electric ATV71HU30S6X Schneider Electric ATV71HU30S6X is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the Altivar 71 series. It features variable speed/frequency drive capabilities with U/F ratio (2 points / 5 points), sensorless flux vector control, ENA System, and vector control with or without speed feedback. It can deliver 220% of the nominal motor torque for 2 seconds and 170% of the nominal motor torque for 60 seconds. Designed with a built-in heatsink, it operates on a supply voltage of 425-660Vac (440Vac / 480Vac / 500Vac /600Vac nom.). The dimensions are H295mm x W210mm x D213mm, and it offers a degree of protection of IP20, IP21, and UL type 1. The rated current is 5.8A (500Vac; 4kHz) with a maximum current of 9.6A for 2 seconds and 8.7A for 60 seconds. It supports wall mounting and uses Modbus and CANopen communication protocols. This 3-phase (3P) network device outputs frequencies ranging from 0.1-599 Hz. It includes 1 analog output (0-10Vdc / 0-20mA), 5 digital inputs (24Vdc; sink/source) programmable as LI1-LI5, 1 digital input programmable as discrete or PTC input (LI6), and 1 digital input for PWR safety. Additionally, it has 1 digital output (C/O SPDT relay contact) (R1) and 2 digital outputs (NO relay contacts) (R2), along with 1 analog input (-10...+10Vdc) and 1 analog input (0-10Vdc / 0-20mA). The current consumption is 9.9A (500Vac) and 10A (600Vac), with a rated active power of 3kW.
Schneider Electric

Part#:ATV71HU30S6X

Manufacturer:Schneider Electric

Product Lifecycle:Active

Get a quick Quote!

Schneider Electric ATV71HU30S6X is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the Altivar 71 series. It features variable speed/frequency drive capabilities with U/F ratio (2 points / 5 points), sensorless flux vector control, ENA System, and vector control with or without speed feedback. It can deliver 220% of the nominal motor torque for 2 seconds and 170% of the nominal motor torque for 60 seconds. Designed with a built-in heatsink, it operates on a supply voltage of 425-660Vac (440Vac / 480Vac / 500Vac /600Vac nom.). The dimensions are H295mm x W210mm x D213mm, and it offers a degree of protection of IP20, IP21, and UL type 1. The rated current is 5.8A (500Vac; 4kHz) with a maximum current of 9.6A for 2 seconds and 8.7A for 60 seconds. It supports wall mounting and uses Modbus and CANopen communication protocols. This 3-phase (3P) network device outputs frequencies ranging from 0.1-599 Hz. It includes 1 analog output (0-10Vdc / 0-20mA), 5 digital inputs (24Vdc; sink/source) programmable as LI1-LI5, 1 digital input programmable as discrete or PTC input (LI6), and 1 digital input for PWR safety. Additionally, it has 1 digital output (C/O SPDT relay contact) (R1) and 2 digital outputs (NO relay contacts) (R2), along with 1 analog input (-10...+10Vdc) and 1 analog input (0-10Vdc / 0-20mA). The current consumption is 9.9A (500Vac) and 10A (600Vac), with a rated active power of 3kW.

About the manufacturer: Schneider Electric is one of the manufacturers that offers Variable Frequency Drives (VFD) that you can order at marketplace.quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the ATV71HU30S6X Schneider Electric price in the box on the right side or send a quick quote.

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


ATV71HU30S6X Description

Schneider Electric ATV71HU30S6X is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the Altivar 71 series. It features variable speed/frequency drive capabilities with U/F ratio (2 points / 5 points), sensorless flux vector control, ENA System, and vector control with or without speed feedback. It can deliver 220% of the nominal motor torque for 2 seconds and 170% of the nominal motor torque for 60 seconds. Designed with a built-in heatsink, it operates on a supply voltage of 425-660Vac (440Vac / 480Vac / 500Vac /600Vac nom.). The dimensions are H295mm x W210mm x D213mm, and it offers a degree of protection of IP20, IP21, and UL type 1. The rated current is 5.8A (500Vac; 4kHz) with a maximum current of 9.6A for 2 seconds and 8.7A for 60 seconds. It supports wall mounting and uses Modbus and CANopen communication protocols. This 3-phase (3P) network device outputs frequencies ranging from 0.1-599 Hz. It includes 1 analog output (0-10Vdc / 0-20mA), 5 digital inputs (24Vdc; sink/source) programmable as LI1-LI5, 1 digital input programmable as discrete or PTC input (LI6), and 1 digital input for PWR safety. Additionally, it has 1 digital output (C/O SPDT relay contact) (R1) and 2 digital outputs (NO relay contacts) (R2), along with 1 analog input (-10...+10Vdc) and 1 analog input (0-10Vdc / 0-20mA). The current consumption is 9.9A (500Vac) and 10A (600Vac), with a rated active power of 3kW.


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Schneider Electric

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Schneider Electric Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Schneider Electric Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Schneider Electric, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

ATV71HU15M3 Part Image. Manufactured by Schneider Electric.

ATV71HU15M3

Verified stock: 0

Schneider Electric ATV71HU15M3 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the Altivar 71 series, designed for variable speed and frequency control with a U/F ratio of either 2 points or 5 points. It features sensorless flux vector control, ENA System, and vector control with or without speed feedback. This model can deliver 220% of the nominal motor torque for 2 seconds and 170% of the nominal motor torque for 60 seconds. It includes a built-in EMC filter and heatsink, operates on a supply voltage of 170-264Vac (200Vac / 220Vac / 230Vac / 240Vac nom.), and has dimensions of H230mm x W130mm x D175mm. The ATV71HU15M3 offers a degree of protection of IP20 UL type 1, with a rated current of 8A (230Vac; 4kHz; 3-phase), 4.8A (230Vac; 4kHz; single-phase), and maximum currents of 7.9A (single-phase; for 2s), 13.2A (3-phase; for 2s), 7.2A (single-phase; for 60s), and 12A (3-phase; for 60s). It supports wall mounting, uses Modbus and CANopen communication protocols, and is compatible with both single-phase (1P) and 3-phase (3P) networks with an output frequency range of 0.1-599 Hz. The drive includes 1 analog output (0-10Vdc / 0-20mA), 5 digital inputs (24Vdc; sink/source) programmable as LI1-LI5, 1 digital input programmable as discrete or PTC input (LI6), and 1 PWR safety input, along with 1 digital output (C/O SPDT relay contact) and 2 digital outputs (NO relay contacts). It also features 1 analog input (-10...+10Vdc) and 1 analog input (0-10Vdc / 0-20mA). The current consumption is specified as 12A (200Vac; 0.75kW; single-phase), 9.6A (240Vac; 1.5kW; 3-phase), 9.9A (240Vac; 0.75kW; single-phase), and 11.3A (200Vac; 1.5kW; 3-phase), with rated active power of 1.5kW (3-phase) and 750W / 0.75kW (single-phase), corresponding to 2HP (3-phase) and 1HP (single-phase).

Schneider Electric

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo