LC1D115G7 Schneider Electric Industrial Automation Components

Schneider Electric LC1D115G7 Schneider Electric LC1D115G7 is a magnetic contactor from the Deca sub-range, featuring screw connections and designed with 3 poles (3P; 3NO). It has a rated current of 200A (AC-1) and 115A (440Vac; AC-3), with a mounting mode suitable for DIN rail installation. The net width of the contactor is 120 mm, and it offers a degree of protection rated at IP20. The control voltage (AC) ranges from 96-138Vac (120Vac nominal; 50Hz/60Hz; 0.8...1.15 x Uc), and the rated operating voltage (Ue) is up to 1000 V. This model includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, with a contacts type of 1NO+1NC instantaneous aux. The rated impulse voltage (Uimp) is 8 kV, and the rated active power (kW) varies from 30kW (220-230Vac; AC-3) up to 80kW (660-690Vac; AC-3), including 65kW at 1000Vac (AC-3). The rated power (HP) for different voltages ranges from 30HP at 200-208Vac to 100HP at 575-600Vac, all for 3-phase, 50Hz/60Hz, UL/CSA. It boasts a mechanical durability of 8,000,000 operations and an electrical durability of 950,000 operations with load, with a rated voltage (AC) - phase-to-phase of 1000 V.
Schneider Electric

Part#:LC1D115G7

Manufacturer:Schneider Electric

Product Lifecycle:Active

In-stock parts: 19

Dec 23, 2024

Schneider Electric LC1D115G7 is a magnetic contactor from the Deca sub-range, featuring screw connections and designed with 3 poles (3P; 3NO). It has a rated current of 200A (AC-1) and 115A (440Vac; AC-3), with a mounting mode suitable for DIN rail installation. The net width of the contactor is 120 mm, and it offers a degree of protection rated at IP20. The control voltage (AC) ranges from 96-138Vac (120Vac nominal; 50Hz/60Hz; 0.8...1.15 x Uc), and the rated operating voltage (Ue) is up to 1000 V. This model includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, with a contacts type of 1NO+1NC instantaneous aux. The rated impulse voltage (Uimp) is 8 kV, and the rated active power (kW) varies from 30kW (220-230Vac; AC-3) up to 80kW (660-690Vac; AC-3), including 65kW at 1000Vac (AC-3). The rated power (HP) for different voltages ranges from 30HP at 200-208Vac to 100HP at 575-600Vac, all for 3-phase, 50Hz/60Hz, UL/CSA. It boasts a mechanical durability of 8,000,000 operations and an electrical durability of 950,000 operations with load, with a rated voltage (AC) - phase-to-phase of 1000 V.

About the manufacturer: Schneider Electric is one of the manufacturers that offers Industrial Automation Components that you can order at marketplace.quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the LC1D115G7 Schneider Electric price in the box on the right side or send a quick quote.

Product Details

  • Product Certifications
    LROS (Lloyds register of shipping) DNV CCC GOST GL CSA UL BV RINA UKCA
  • Motor Power Kw
    30 kW 220...230 V AC 50/60 Hz AC-3) 55 kW 380...400 V AC 50/60 Hz AC-3) 59 kW 415...440 V AC 50/60 Hz AC-3) 75 kW 500 V AC 50/60 Hz AC-3) 80 kW 660...690 V AC 50/60 Hz AC-3) 65 kW 1000 V AC 50/60 Hz AC-3) 18.5 kW 400 V AC 50/
  • [Icw] Rated Short-Time Withstand Current
    250 A 104 °F (40 °C) - 10 min power circuit 550 A 104 °F (40 °C) - 1 min power circuit 950 A 104 °F (40 °C) - 10 s power circuit 1100 A 104 °F (40 °C) - 1 s power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling ci
  • Standards
    CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
  • [Ui] Rated Insulation Voltage
    Power circuit 600 V CSA Power circuit 600 V UL Power circuit 1000 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
  • Motor Power HP (UL / CSA)
    30 hp 200/208 V at AC 50/60 Hz for 3 phase 40 hp 230/240 V at AC 50/60 Hz for 3 phase 75 hp 460/480 V at AC 50/60 Hz for 3 phase 100 hp 575/600 V at AC 50/60 Hz for 3 phase
  • Tightening Torque
    Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.21 lbf.in (12 N.m) connector hexagonal 0.16 in (4 mm)
  • Connections - Terminals
    Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)fl
  • Control Circuit Voltage Limits
    0.3...0.5 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.15 Uc -40…131 °F (-40…55 °C) operational AC 50/60 Hz 1...1.15 Uc 131…158 °F (55…70 °C) operational AC 50/60 Hz
  • Associated Fuse Rating
    250 A gG <= 690 V type 1 power circuit 200 A gG <= 690 V type 2 power circuit 10 A gG signalling circuit
  • Irms Rated Making Capacity
    1260 A 440 V power circuit IEC 60947 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1
  • Utilisation Category
    AC-1 AC-4 AC-3
  • Hold-In Power Consumption In VA
    2…18 VA 60 Hz 0.3 68 °F (20 °C)) 2…18 VA 50 Hz 0.3 68 °F (20 °C))
  • Inrush Power In VA
    280…350 VA 60 Hz 0.8 68 °F (20 °C)) 280…350 VA 50 Hz 0.8 68 °F (20 °C))
  • [Ie] Rated Operational Current
    200 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit 115 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
  • Non-Overlap Time
    1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
  • Power Dissipation Per Pole
    24 W AC-1 7.9 W AC-3
  • [Ue] Rated Operational Voltage
    Power circuit <= 1000 V AC 25...400 Hz Power circuit <= 300 V DC
  • Auxiliary Contacts Type
    Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
  • Safety Reliability Level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Mounting Support
    Rail Plate
  • Electrical Durability
    0.8 Mcycles 200 A AC-1 <= 440 V 0.95 Mcycles 115 A AC-3 <= 440 V
  • Operating Time
    6...20 ms opening 20...50 ms closing
  • Contactor Application
    Resistive load Motor control
  • Insulation Resistance
    > 10 MOhm signalling circuit
  • Minimum Switching Voltage
    17 V signalling circuit
  • Minimum Switching Current
    5 mA signalling circuit
  • Signalling Circuit Frequency
    25...400 Hz
  • Heat Dissipation
    3…8 W 50/60 Hz
  • Coil Technology
    Built-in bidirectional peak limiting diode suppressor
  • Maximum Operating Rate
    2400 cyc/h 60 °C
  • Mechanical Durability
    8 Mcycles
  • Front Cover
    With
  • Rated Breaking Capacity
    1100 A 440 V power circuit IEC 60947
  • Average Impedance
    0.6 mOhm - Ith 200 A 50 Hz power circuit
  • [Ith] Conventional Free Air Thermal Current
    200 A 140 °F (60 °C) power circuit
  • Control Circuit Type
    AC at 50/60 Hz
  • Overvoltage Category
    III
  • [Uc] Control Circuit Voltage
    120 V AC 50/60 Hz
  • [Uimp] Rated Impulse Withstand Voltage
    8 kV IEC 60947
  • Auxiliary Contact Composition
    1 NO + 1 NC
  • Product Or Component Type
    Contactor
  • Product Name
    TeSys D
  • Power Pole Contact Composition
    3 NO
  • Poles Description
    3P
  • Device Short Name
    LC1D
  • Range
    TeSys

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



This item can ship within 24h!

1-year warranty

$402.00

Stock:

19

Select Qty:

$402.00

$402.00 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Schneider Electric

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Schneider Electric Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Schneider Electric Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Schneider Electric, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo