LC1D32F7 Schneider Electric Industrial Automation Components

Schneider Electric LC1D32F7 Schneider Electric LC1D32F7 is a magnetic contactor from the Deca sub-range, featuring screw connections and designed with 3 poles (3P; 3NO). It has a rated current of 50A (AC-1) and 32A (440Vac; AC-3), with a mounting mode suitable for DIN rail installation. The net width of the contactor is 45 mm, and it offers a degree of protection rated at IP20. The control voltage (AC) ranges from 88-121Vac (110Vac nominal; 50Hz; 0.8...1.1 x Uc) to 93.5-121Vac (110Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of up to 690 V. It includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, with a contacts type of 1NO+1NC instantaneous aux. The rated impulse voltage (Uimp) is 6 kV, and the rated active power (kW) spans from 7.5kW at 220-230Vac (AC-3) up to 18.5kW at 660-690Vac (AC-3). The rated power (HP) for various voltages and phases under UL/CSA standards ranges from 2HP at 115Vac, single-phase, to 25HP at 575-600Vac, 3-phase. Mechanical durability is noted at 15,000,000 operations, and electrical durability with load at 1,600,000 operations. The rated voltage (AC) for phase-to-phase connections is 690 V.
Schneider Electric

Part#:LC1D32F7

Manufacturer:Schneider Electric

Product Lifecycle:Active

In-stock parts: 25

Apr 4, 2025

Schneider Electric LC1D32F7 is a magnetic contactor from the Deca sub-range, featuring screw connections and designed with 3 poles (3P; 3NO). It has a rated current of 50A (AC-1) and 32A (440Vac; AC-3), with a mounting mode suitable for DIN rail installation. The net width of the contactor is 45 mm, and it offers a degree of protection rated at IP20. The control voltage (AC) ranges from 88-121Vac (110Vac nominal; 50Hz; 0.8...1.1 x Uc) to 93.5-121Vac (110Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of up to 690 V. It includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, with a contacts type of 1NO+1NC instantaneous aux. The rated impulse voltage (Uimp) is 6 kV, and the rated active power (kW) spans from 7.5kW at 220-230Vac (AC-3) up to 18.5kW at 660-690Vac (AC-3). The rated power (HP) for various voltages and phases under UL/CSA standards ranges from 2HP at 115Vac, single-phase, to 25HP at 575-600Vac, 3-phase. Mechanical durability is noted at 15,000,000 operations, and electrical durability with load at 1,600,000 operations. The rated voltage (AC) for phase-to-phase connections is 690 V.

About the manufacturer: Schneider Electric is one of the manufacturers that offers Industrial Automation Components that you can order at marketplace.quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the LC1D32F7 Schneider Electric price in the box on the right side or send a quick quote.

Product Details

  • Product Certifications
    GOST BV LROS (Lloyds register of shipping) RINA CCC DNV UL CSA GL
  • Motor Power HP (UL / CSA)
    2 hp 115 V at AC 50/60 Hz for 1 phase 5 hp 230/240 V at AC 50/60 Hz for 1 phase 7.5 hp 200/208 V at AC 50/60 Hz for 3 phase 10 hp 230/240 V at AC 50/60 Hz for 3 phase 20 hp 460/480 V at AC 50/60 Hz for 3 phase 30 hp 575/600 V at A
  • [Ui] Rated Insulation Voltage
    Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
  • Motor Power Kw
    7.5 kW 220...230 V AC 50/60 Hz AC-3) 15 kW 380...400 V AC 50/60 Hz AC-3) 15 kW 415...440 V AC 50/60 Hz AC-3) 18.5 kW 500 V AC 50/60 Hz AC-3) 18.5 kW 660...690 V AC 50/60 Hz AC-3) 7.5 kW 400 V AC 50/60 Hz AC-4)
  • Standards
    CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
  • [Icw] Rated Short-Time Withstand Current
    260 A 104 °F (40 °C) - 10 s power circuit 430 A 104 °F (40 °C) - 1 s power circuit 60 A 104 °F (40 °C) - 10 min power circuit 138 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circ
  • Tightening Torque
    Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals flat Ø 6 mm Power circuit 22.13 lb
  • Control Circuit Voltage Limits
    0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
  • Associated Fuse Rating
    10 A gG signalling circuit IEC 60947-5-1 63 A gG <= 690 V type 1 power circuit 63 A gG <= 690 V type 2 power circuit
  • Connections - Terminals
    Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)fl
  • Irms Rated Making Capacity
    140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 550 A 440 V power circuit IEC 60947
  • Utilisation Category
    AC-1 AC-3 AC-4
  • Electrical Durability
    1.65 Mcycles 32 A AC-3 <= 440 V 1.4 Mcycles 50 A AC-1 <= 440 V
  • Non-Overlap Time
    1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
  • Hold-In Power Consumption In VA
    7.5 VA 60 Hz 0.3 68 °F (20 °C)) 7 VA 50 Hz 0.3 68 °F (20 °C))
  • Safety Reliability Level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • [Ue] Rated Operational Voltage
    Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
  • Mounting Support
    Plate Rail
  • Operating Time
    12...22 ms closing 4...19 ms opening
  • [Ith] Conventional Free Air Thermal Current
    10 A 140 °F (60 °C) signalling circuit 50 A 140 °F (60 °C) power circuit
  • Auxiliary Contacts Type
    Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
  • Inrush Power In VA
    70 VA 60 Hz 0.75 68 °F (20 °C)) 70 VA 50 Hz 0.75 68 °F (20 °C))
  • Power Dissipation Per Pole
    2 W AC-3 5 W AC-1
  • [Ie] Rated Operational Current
    32 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit 50 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
  • Contactor Application
    Resistive load Motor control
  • Insulation Resistance
    > 10 MOhm signalling circuit
  • Heat Dissipation
    2…3 W 50/60 Hz
  • Coil Technology
    Without built-in suppressor module
  • Minimum Switching Current
    5 mA signalling circuit
  • Minimum Switching Voltage
    17 V signalling circuit
  • Signalling Circuit Frequency
    25...400 Hz
  • Maximum Operating Rate
    3600 cyc/h 140 °F (60 °C)
  • Mechanical Durability
    15 Mcycles
  • Front Cover
    With
  • Average Impedance
    2 mOhm - Ith 50 A 50 Hz power circuit
  • Rated Breaking Capacity
    550 A 440 V power circuit IEC 60947
  • Control Circuit Type
    AC 50/60 Hz
  • Auxiliary Contact Composition
    1 NO + 1 NC
  • Overvoltage Category
    III
  • [Uimp] Rated Impulse Withstand Voltage
    6 kV IEC 60947
  • [Uc] Control Circuit Voltage
    110 V AC 50/60 Hz
  • Product Or Component Type
    Contactor
  • Power Pole Contact Composition
    3 NO
  • Poles Description
    3P
  • Product Name
    TeSys D
  • Device Short Name
    LC1D
  • Range
    TeSys

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



This item can ship within 5 days!

1-year warranty

$106.66

Stock:

25

Select Qty:

$106.66

$106.66 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Schneider Electric

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Schneider Electric Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Schneider Electric Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Schneider Electric, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo