B&R X20CM8281 X20 universal mixed module, 4 digital inputs, 24 VDC, sink, 1-wire connections, 2 digital outputs, 0.5 A, source, 1-wire connections, 1 analog input, ±10 V or 0 to 20 mA / 4 to 20 mA, 12-bit converter resolution, 1 analog output, ±10 V / 0 to 20 mA, 12-bi
B&R

Part#:X20CM8281

Manufacturer:B&R

Product Lifecycle:Active

In-stock parts: 5

Dec 22, 2024

X20 universal mixed module, 4 digital inputs, 24 VDC, sink, 1-wire connections, 2 digital outputs, 0.5 A, source, 1-wire connections, 1 analog input, ±10 V or 0 to 20 mA / 4 to 20 mA, 12-bit converter resolution, 1 analog output, ±10 V / 0 to 20 mA, 12-bi

Check out the X20CM8281 B&R price in the box on the right side or send a quick quote.

Product Details

  • Max. error Voltage Gain
    0.08%
  • Temperature Operation Vertical mounting orientation
    -25 to 50°C
  • Temperature Operation Horizontal mounting orientation
    -25 to 60°C
  • Max. error Current Offset
    0 to 20 mA = 0.03% / 4 to 20 mA = 0.16%
  • Output of digital value during overload Overshoot Current
    0x7FFF
  • Max. error Voltage Offset
    0.02%
  • Max. error Current Gain
    0 to 20 mA = 0.08% / 4 to 20 mA = 0.1%
  • Output of digital value during overload Undershoot Current
    0x0000
  • Output of digital value during overload Undershoot Voltage
    0x8001
  • Output of digital value during overload Overshoot Voltage
    0x7FFF
  • Relative humidity Transport
    5 to 95%, non-condensing
  • Relative humidity Operation
    5 to 95%, non-condensing
  • Relative humidity Storage
    5 to 95%, non-condensing
  • Temperature Derating
    See section "Derating".
  • Temperature Transport
    -40 to 85°C
  • Temperature Storage
    -40 to 85°C
  • Installation elevation above sea level >2000 m
    Reduction of ambient temperature by 0.5°C per 100 m
  • Mounting orientation Vertical
    Yes
  • Error caused by load change Voltage
    Max. 0.02%, from 10 MΩ → 1 kΩ, resistive
  • Error caused by load change Current
    Max. 0.5%, from 1 Ω → 400 Ω, resistive
  • Installation elevation above sea level 0 to 2000 m
    No limitation
  • Mounting orientation Horizontal
    Yes
  • Load per channel Current
    Max. load is 400 Ω
  • Switching frequency Inductive load
    See section "Switching inductive loads".
  • Load per channel Voltage
    Max. ±10 mA, load ≥ 1 kΩ
  • Switching frequency Resistive load
    Max. 100 Hz
  • Switching delay 1 → 0
    <270 µs
  • Nonlinearity Current
    <0.02%
  • Switching delay 0 → 1
    <250 µs
  • Max. offset drift Current
    0 to 20 mA = 0.004 %/°C ; 4 to 20 mA = 0.005 %/°C
  • Max. offset drift Voltage
    0.002%/°C
  • Nonlinearity Voltage
    <0.02%
  • Max. gain drift Current
    0 to 20 mA = 0.009 %/°C ; 4 to 20 mA = 0.0113 %/°C
  • Max. gain drift Voltage
    0.01%/°C
  • Permissible input signal Voltage
    Max. ±15 V
  • Permissible input signal Current
    Max. ±50 mA
  • Load Current
    <300 Ω
  • Load Voltage
    -
  • Input impedance in signal range Current
    -
  • Output format Voltage
    INT 0x8001 - 0x7FFF / 1 LSB = 0x0008 = 2.441 mV
  • Input impedance in signal range Voltage
    >1 MΩ
  • Digital converter resolution Current
    12-bit
  • Output format Current
    INT 0x0000 - 0x7FFF / 1 LSB = 0x0008 = 4.883 µA
  • Switching threshold High
    >15 VDC
  • Counter frequency Internal
    48 MHz, 24 MHz, 12 MHz, 6 MHz, 3 MHz, 1.5 MHz, 750 kHz, 375 kHz, 187.5 kHz
  • Digital converter resolution Voltage
    ±12-bit
  • Switching threshold Low
    <5 VDC
  • Input filter Software
    Default 1 ms, configurable between 0 and 25 ms in 0.2 ms increments
  • Input filter Hardware
    ≤2 µs
  • Certifications EAC
    Yes
  • Certifications KC
    Yes
  • Certifications KR
    Yes
  • Certifications ABS
    Yes
  • Certifications DNV
    Temperature: B (0 - 55°C); Humidity: B (up to 100%); Vibration: B (4 g); EMC: B (bridge and open deck)
  • Certifications LR
    ENV1
  • Certifications HazLoc
    cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
  • Certifications UL
    cULus E115267; Industrial control equipment
  • Certifications ATEX
    Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
  • Certifications UKCA
    Yes
  • Diagnostics Analog inputs
    Yes, using LED status indicator and software
  • Power consumption Bus
    0.01 W
  • Certifications CE
    Yes
  • Diagnostics Module run/error
    Yes, using LED status indicator and software
  • Pitch
    12.5+0.2 mm
  • Power consumption Internal I/O
    1.75 W
  • Diagnostics Digital outputs
    Yes, using LED status indicator and software (output error status)
  • Note
    Order 1x terminal block X20TB12 separately.; Order 1x bus module X20BM11 separately.
  • Degree of protection per EN 60529
    IP20
  • Nonlinearity
    <0.1%
  • Settling time on output change over entire range
    1 ms
  • Output
    ±10 V or 0 to 20 mA, via different terminal connections
  • Braking voltage when switching off inductive loads
    Typ. 50 VDC
  • Electrical isolation
    Channel isolated from bus; Channel not isolated from channel
  • Switch on/off behavior
    Internal enable relay for startup and errors
  • Digital converter resolution
    12-bit
  • Peak short-circuit current
    <14 A
  • Switch-on in the event of overload shutdown or short-circuit shutdown
    Approx. 10 ms (depends on the module temperature)
  • RDS(on)
    105 mΩ
  • Leakage current when the output is switched off
    5 µA
  • Output protection
    Thermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads, reverse polarity protection
  • Switching voltage
    24 VDC -15% / +20%
  • Diagnostic status
    Output monitoring with 10 ms delay
  • Total nominal current
    1 A
  • Variant
    Current-sourcing FET
  • Output circuit
    Source
  • Nominal output current
    0.5 A
  • Input filter
    Second-order low-pass filter / Cutoff frequency 1 kHz
  • Conversion procedure
    Successive approximation
  • Input protection
    Protection against wiring with supply voltage
  • Input
    ±10 V or 0 to 20 mA / 4 to 20 mA, via different terminal connections
  • Conversion time
    400 µs, conversion runs asynchronous to the X2X Link cycle
  • Output format
    INT
  • Input type
    Single-ended
  • Pulse length
    ≥20 µs
  • Supported inputs
    Input 4
  • Length of pause between pulses
    ≥100 µs
  • Counter size
    16-bit
  • Counter frequency
    Max. 20 kHz
  • Input frequency
    Max. 20 kHz
  • Evaluation
    Each negative edge, cyclic counter
  • Signal form
    Square wave pulse
  • Counter 1
    Input 1
  • Counter 2
    Input 3
  • Insulation voltage between channel and bus
    500 Veff
  • Connection type
    1-wire connections
  • Additional functions
    20 kHz event counting, gate measurement
  • Input resistance
    Typ. 7.18 kΩ
  • I/O module
    4 digital inputs, 2 digital outputs, 1 analog input, 1 analog output, special functions
  • Input circuit
    Sink
  • Input voltage
    24 VDC -15% / +20%
  • B&R ID code
    0x24C3
  • Quantity
    4
  • Input characteristics per EN 61131-2
    Type 1
  • Nominal voltage
    24 VDC
  • Input current at 24 VDC
    Typ. 3.3 mA
  • Status indicators
    I/O function per channel, operating state, module status

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



1-year warranty

Get a quick Quote!

Request a quote, and we will send you price within minutes.

Stock:

5

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of B&R

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

B&R Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo