RD800-MP-M12R Leuze Safety Proximity Sensors

Leuze RD800-MP-M12R RD800-MP-M12R Leuze - Safety transponder
Leuze

Part#:RD800-MP-M12R

Manufacturer:Leuze

Alt. Part#:63002020

Product Lifecycle:Active

Get a quick Quote!

RD800-MP-M12R Leuze - Safety transponder

Check out the RD800-MP-M12R Leuze price in the box on the right side or send a quick quote.

Product Details

  • Customs tariff number
    85369095
  • Approvals
    TÜV Süd; c UL US
  • Test procedure for vibration in accordance with standard
    EN 60068-2-6
  • Test procedure for shock in accordance with standard
    EN 60068-2-27
  • Number of LEDs
    4 Piece(s)
  • Degree of contamination
    3, EN 60947-1
  • Ambient temperature, operation
    -25 ... 70 °C
  • Degree of protection
    IP 67; IP 69K
  • Ambient temperature, storage
    -25 ... 85 °C
  • Screw tightening torque
    0.8 ... 2 N·m
  • Type of display
    LED
  • Assured cut-out distance (Sar), min.
    16 mm
  • Repeatability, max.
    1.2 mm
  • Distance between two systems (sensor, actuator), min.
    50 mm
  • Nominal operating distance, max.
    12 mm
  • Nominal switch-off distance, max.
    14 mm
  • Assured cut-in distance (Sao), max.
    10 mm
  • Switching hysteresis, max.
    2.4 mm
  • Type of fastening
    Through-hole mounting
  • Housing color
    Black
  • Net weight
    57 g
  • Plastic housing
    PA 66
  • Housing material
    Plastic
  • Dimension (W x H x L)
    25 mm x 18 mm x 72 mm
  • Design
    Cubic
  • Plug outlet
    On right side
  • Length of connection cable, max.
    50 m
  • Material
    Metal
  • Thread size
    M12
  • No. of pins
    8 -pin
  • Reaction time after removing the actuator, max.
    150 ms
  • Type of connection
    Connector
  • Reaction time after shutdown, input, max.
    12 ms
  • Capacitance, max. between an output and GND
    200 nF
  • Switching current, max.
    100 mA
  • Number of connections
    1 Piece(s)
  • Function
    Signal output
  • Reaction time after removing the actuator, min.
    80 ms
  • Capacitance, max. between two outputs
    200 nF
  • Switching element
    Transistor, PNP
  • Reaction time after shutdown, input, min.
    7 ms
  • Number of safety-related switching outputs (OSSDs)
    2 Piece(s)
  • Test-pulse length, max.
    0.3 ms
  • Number of digital switching inputs
    2 Piece(s)
  • Output current, max.
    250 mA
  • Switching power, max.
    6 W
  • Fuse, internal
    0.75 A polyfuse (O1 + O2 + O3)
  • Number of digital switching outputs
    1 Piece(s)
  • Switching voltage, type.
    24 V
  • Rated insulation voltage
    32 V DC
  • Voltage type
    DC
  • Type
    Digital switching input
  • Conventional thermal current, max.
    0.25 A
  • Fuse, external
    1 A
  • Overvoltage category
    III
  • Power consumption, max.
    1 W
  • Usage category at DC 12
    Ue 24 V, Ie 0.25 A, EN 60947-5-1
  • Current consumption, max.
    250 mA
  • Pulse resistance
    1,500 V
  • Category
    Up to and including 4, EN ISO 13849
  • Nominal current, min.
    0.5 mA
  • MTTFd
    4,077 years, EN ISO 13849-1
  • DC
    High
  • Supply voltage UB
    24 V, DC, -15 ... 10 %
  • Protective circuit
    Cross circuit protection; Short circuit protected
  • Series
    RD800
  • SIL
    Up to 3, IEC 61508
  • SILCL
    Up to 3, IEC/EN 62061
  • Mission time
    20 years, EN ISO 13849-1
  • PFHD
    1.45E-09 per hour
  • Performance Level (PL)
    Up to and including e, EN ISO 13849-1
  • Code type
    Flexible programming
  • Application
    Individual use; Series use

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


RD800-MP-M12R Description

RD800-MP-M12R Leuze - Safety transponder



Related documents RD800-MP-M12R Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Leuze

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Leuze Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Leuze Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Leuze, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo