RD800-MP-M12R Leuze Safety Proximity Sensors
Part#:RD800-MP-M12R
Manufacturer:Leuze
Alt. Part#:63002020
Product Lifecycle:Active
Get a quick Quote!
RD800-MP-M12R Leuze - Safety transponder
Check out the RD800-MP-M12R Leuze price in the box on the right side or send a quick quote.
Product Details
- Customs tariff number 85369095
- Approvals TÜV Süd; c UL US
- Test procedure for vibration in accordance with standard EN 60068-2-6
- Test procedure for shock in accordance with standard EN 60068-2-27
- Number of LEDs 4 Piece(s)
- Degree of contamination 3, EN 60947-1
- Ambient temperature, operation -25 ... 70 °C
- Degree of protection IP 67; IP 69K
- Ambient temperature, storage -25 ... 85 °C
- Screw tightening torque 0.8 ... 2 N·m
- Type of display LED
- Assured cut-out distance (Sar), min. 16 mm
- Repeatability, max. 1.2 mm
- Distance between two systems (sensor, actuator), min. 50 mm
- Nominal operating distance, max. 12 mm
- Nominal switch-off distance, max. 14 mm
- Assured cut-in distance (Sao), max. 10 mm
- Switching hysteresis, max. 2.4 mm
- Type of fastening Through-hole mounting
- Housing color Black
- Net weight 57 g
- Plastic housing PA 66
- Housing material Plastic
- Dimension (W x H x L) 25 mm x 18 mm x 72 mm
- Design Cubic
- Plug outlet On right side
- Length of connection cable, max. 50 m
- Material Metal
- Thread size M12
- No. of pins 8 -pin
- Reaction time after removing the actuator, max. 150 ms
- Type of connection Connector
- Reaction time after shutdown, input, max. 12 ms
- Capacitance, max. between an output and GND 200 nF
- Switching current, max. 100 mA
- Number of connections 1 Piece(s)
- Function Signal output
- Reaction time after removing the actuator, min. 80 ms
- Capacitance, max. between two outputs 200 nF
- Switching element Transistor, PNP
- Reaction time after shutdown, input, min. 7 ms
- Number of safety-related switching outputs (OSSDs) 2 Piece(s)
- Test-pulse length, max. 0.3 ms
- Number of digital switching inputs 2 Piece(s)
- Output current, max. 250 mA
- Switching power, max. 6 W
- Fuse, internal 0.75 A polyfuse (O1 + O2 + O3)
- Number of digital switching outputs 1 Piece(s)
- Switching voltage, type. 24 V
- Rated insulation voltage 32 V DC
- Voltage type DC
- Type Digital switching input
- Conventional thermal current, max. 0.25 A
- Fuse, external 1 A
- Overvoltage category III
- Power consumption, max. 1 W
- Usage category at DC 12 Ue 24 V, Ie 0.25 A, EN 60947-5-1
- Current consumption, max. 250 mA
- Pulse resistance 1,500 V
- Category Up to and including 4, EN ISO 13849
- Nominal current, min. 0.5 mA
- MTTFd 4,077 years, EN ISO 13849-1
- DC High
- Supply voltage UB 24 V, DC, -15 ... 10 %
- Protective circuit Cross circuit protection; Short circuit protected
- Series RD800
- SIL Up to 3, IEC 61508
- SILCL Up to 3, IEC/EN 62061
- Mission time 20 years, EN ISO 13849-1
- PFHD 1.45E-09 per hour
- Performance Level (PL) Up to and including e, EN ISO 13849-1
- Code type Flexible programming
- Application Individual use; Series use
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
RD800-MP-M12R Description
RD800-MP-M12R Leuze - Safety transponder
Related documents RD800-MP-M12R Specs
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Leuze
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Leuze Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Leuze Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Leuze, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨