Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

RD800-MUCA-CB2-R Leuze Safety Proximity Sensors

Leuze RD800-MUCA-CB2-R RD800-MUCA-CB2-R Leuze - Safety transponder
Leuze

Part#:RD800-MUCA-CB2-R

Manufacturer:Leuze

Alt. Part#:63002061

Product Lifecycle:Active

Get a quick Quote!

RD800-MUCA-CB2-R Leuze - Safety transponder

Check out the RD800-MUCA-CB2-R Leuze price in the box on the right side or send a quick quote.

Product Details

  • Degree of protection
    IP 67; IP 69K
  • Test procedure for vibration in accordance with standard
    EN 60068-2-6
  • Test procedure for shock in accordance with standard
    EN 60068-2-27
  • Customs tariff number
    85369095
  • Distance between two systems (sensor, actuator), min.
    50 mm
  • Assured cut-out distance (Sar), min.
    16 mm
  • Nominal switch-off distance, max.
    14 mm
  • Assured cut-in distance (Sao), max.
    10 mm
  • Housing color
    Black
  • Type of fastening
    Through-hole mounting
  • Switching hysteresis, max.
    2.4 mm
  • Net weight
    150 g
  • Housing material
    Plastic
  • Plastic housing
    PA 66
  • Design
    Cubic
  • Dimension (W x H x L)
    25 mm x 18 mm x 72 mm
  • Type of connection
    Cable
  • Length of connection cable, max.
    50 m
  • Number of conductors
    8 -wire
  • Cable color
    Black
  • Reaction time after shutdown, input, max.
    12 ms
  • Ambient temperature, operation
    -25 ... 70 °C
  • Type of display
    LED
  • Approvals
    TÜV Süd; c UL US
  • Number of LEDs
    4 Piece(s)
  • Ambient temperature, storage
    -25 ... 85 °C
  • Degree of contamination
    3, EN 60947-1
  • Screw tightening torque
    0.8 N·m
  • Repeatability, max.
    1.2 mm
  • Nominal operating distance, max.
    12 mm
  • Sheathing material
    PVC
  • Number of connections
    1 Piece(s)
  • Connector
    On right side
  • Reaction time after removing the actuator, max.
    150 ms
  • Cable length
    2,000 mm
  • Reaction time after shutdown, input, min.
    7 ms
  • Reaction time after removing the actuator, min.
    80 ms
  • Function
    Signal output
  • Capacitance, max. between an output and GND
    200 nF
  • Switching current, max.
    100 mA
  • Output current, max.
    250 mA
  • Switching element
    Transistor, PNP
  • Number of digital switching outputs
    1 Piece(s)
  • Test-pulse length, max.
    0.3 ms
  • Switching power, max.
    6 W
  • Voltage type
    DC
  • Capacitance, max. between two outputs
    200 nF
  • Number of safety-related switching outputs (OSSDs)
    2 Piece(s)
  • Switching voltage, type.
    24 V
  • Fuse, external
    1 A
  • Rated insulation voltage
    32 V DC
  • Fuse, internal
    0.75 A polyfuse (O1 + O2 + O3)
  • Number of digital switching inputs
    2 Piece(s)
  • Conventional thermal current, max.
    0.25 A
  • Type
    Digital switching input
  • Overvoltage category
    III
  • SILCL
    Up to 3, IEC/EN 62061
  • Nominal current, min.
    0.5 mA
  • Power consumption, max.
    1 W
  • Protective circuit
    Cross circuit protection; Short circuit protected
  • Current consumption, max.
    250 mA
  • Usage category at DC 12
    Ue 24 V, Ie 0.25 A, EN 60947-5-1
  • Supply voltage UB
    24 V, DC, -15 ... 10 %
  • Pulse resistance
    1,500 V
  • Series
    RD800
  • Code type
    Unique code
  • DC
    High
  • Category
    Up to and including 4, EN ISO 13849
  • Application
    Individual use; Series use
  • Performance Level (PL)
    Up to and including e, EN ISO 13849-1
  • MTTFd
    4,077 years, EN ISO 13849-1
  • SIL
    Up to 3, IEC 61508
  • PFHD
    1.45E-09 per hour
  • Mission time
    20 years, EN ISO 13849-1

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


RD800-MUCA-CB2-R Description

RD800-MUCA-CB2-R Leuze - Safety transponder



Related documents RD800-MUCA-CB2-R Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Leuze

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Leuze Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Leuze Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Leuze, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo