RD800-MUCA-M12L Leuze Safety Proximity Sensors

Leuze RD800-MUCA-M12L RD800-MUCA-M12L Leuze - Safety transponder
Leuze

Part#:RD800-MUCA-M12L

Manufacturer:Leuze

Alt. Part#:63002013

Product Lifecycle:Active

Get a quick Quote!

RD800-MUCA-M12L Leuze - Safety transponder

Check out the RD800-MUCA-M12L Leuze price in the box on the right side or send a quick quote.

Product Details

  • Approvals
    TÜV Süd; c UL US
  • Test procedure for vibration in accordance with standard
    EN 60068-2-6
  • Customs tariff number
    85369095
  • Test procedure for shock in accordance with standard
    EN 60068-2-27
  • Degree of protection
    IP 67; IP 69K
  • Degree of contamination
    3, EN 60947-1
  • Ambient temperature, operation
    -25 ... 70 °C
  • Repeatability, max.
    1.2 mm
  • Type of display
    LED
  • Ambient temperature, storage
    -25 ... 85 °C
  • Number of LEDs
    4 Piece(s)
  • Screw tightening torque
    0.8 ... 2 N·m
  • Distance between two systems (sensor, actuator), min.
    50 mm
  • Nominal switch-off distance, max.
    14 mm
  • Nominal operating distance, max.
    12 mm
  • Type of fastening
    Through-hole mounting
  • Assured cut-in distance (Sao), max.
    10 mm
  • Assured cut-out distance (Sar), min.
    16 mm
  • Housing color
    Black
  • Switching hysteresis, max.
    2.4 mm
  • Net weight
    57 g
  • Design
    Cubic
  • Dimension (W x H x L)
    25 mm x 18 mm x 72 mm
  • Plastic housing
    PA 66
  • Length of connection cable, max.
    50 m
  • Plug outlet
    On left side
  • Thread size
    M12
  • Housing material
    Plastic
  • Material
    Metal
  • Type of connection
    Connector
  • No. of pins
    8 -pin
  • Reaction time after shutdown, input, min.
    7 ms
  • Reaction time after removing the actuator, max.
    150 ms
  • Number of connections
    1 Piece(s)
  • Reaction time after shutdown, input, max.
    12 ms
  • Function
    Signal output
  • Reaction time after removing the actuator, min.
    80 ms
  • Switching current, max.
    100 mA
  • Test-pulse length, max.
    0.3 ms
  • Capacitance, max. between an output and GND
    200 nF
  • Switching element
    Transistor, PNP
  • Number of digital switching outputs
    1 Piece(s)
  • Capacitance, max. between two outputs
    200 nF
  • Type
    Digital switching input
  • Voltage type
    DC
  • Number of digital switching inputs
    2 Piece(s)
  • Output current, max.
    250 mA
  • Switching power, max.
    6 W
  • Switching voltage, type.
    24 V
  • Number of safety-related switching outputs (OSSDs)
    2 Piece(s)
  • Conventional thermal current, max.
    0.25 A
  • Fuse, internal
    0.75 A polyfuse (O1 + O2 + O3)
  • Overvoltage category
    III
  • Fuse, external
    1 A
  • Rated insulation voltage
    32 V DC
  • Nominal current, min.
    0.5 mA
  • Power consumption, max.
    1 W
  • Current consumption, max.
    250 mA
  • Usage category at DC 12
    Ue 24 V, Ie 0.25 A, EN 60947-5-1
  • Supply voltage UB
    24 V, DC, -15 ... 10 %
  • Protective circuit
    Cross circuit protection; Short circuit protected
  • Pulse resistance
    1,500 V
  • Category
    Up to and including 4, EN ISO 13849
  • DC
    High
  • Code type
    Unique code
  • SILCL
    Up to 3, IEC/EN 62061
  • MTTFd
    4,077 years, EN ISO 13849-1
  • SIL
    Up to 3, IEC 61508
  • PFHD
    1.45E-09 per hour
  • Mission time
    20 years, EN ISO 13849-1
  • Performance Level (PL)
    Up to and including e, EN ISO 13849-1
  • Series
    RD800
  • Application
    Individual use; Series use

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


RD800-MUCA-M12L Description

RD800-MUCA-M12L Leuze - Safety transponder



Related documents RD800-MUCA-M12L Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Leuze

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Leuze Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Leuze Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Leuze, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo