Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

1046800 Phoenix Contact DC/DC Converters

Phoenix Contact 1046800 Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, SFB Technology (Selective Fuse Breaking), Screw connection, input: 24 V DC , output: 24 V DC / 5 A
Phoenix Contact

Part#:1046800

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 3

Dec 22, 2024

Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, SFB Technology (Selective Fuse Breaking), Screw connection, input: 24 V DC , output: 24 V DC / 5 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1046800 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Weight0.6 kg
  • Typical current consumption
    6.9 A (24 V DC)
  • Inrush current integral (I2t)
    < 0.05 A2s
  • Production test B
    2 kV DC
  • Connection method
    Screw connection
  • Conductor cross section flexible
    0.2 mm² ... 1.5 mm²
  • Dynamic Boost (IDyn.Boost)
    10 A (5 s)
  • Selective Fuse Breaking (ISFB)
    30 A (15 ms)
  • Feedback voltage resistance
    ≤ 35 V DC
  • UIn
    > 0.8 x UInNom (LED off)
  • Default
    Output power ON (>40 kΩ/24 V DC/open bridge between REM and SGnd)
  • Output current
    5 A
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Height
    130 mm
  • Electric strength, max.
    35 V DC (60 s)
  • Typical response time
    300 ms (from SLEEP MODE)
  • Input fuse
    15 A (slow-blow, internal)
  • Production test D
    0.5 kV DC
  • Input voltage range
    18 V DC ... 32 V DC
  • Switch-on time
    < 1 s
  • Type test (IEC/EN 60950-1) A
    2 kV DC
  • Type test (IEC/EN 60950-1) D
    0.5 kV DC
  • Production test C
    0.5 kV DC
  • Nominal output voltage (UN)
    24 V DC
  • Magnetic circuit breaker tripping
    A1 ... A4 / B2 / C1 ... C2 / Z1 ... Z4
  • System deviation, dynamic
    < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
  • System deviation, input voltage change
    < 0.1 % (change in input voltage ±10 %)
  • Rise time
    < 1 s (UOUT (10 % ... 90 %))
  • POut
    > 100 % (LED lights up yellow, output power > 120 W)
  • Signal option
    Output current
  • Reference potential
    to OUT1, OUT2, REM
  • Voltage
    1 kV
  • Main converter stage
    50 kHz ... 420 kHz (Main converter stage)
  • Depth
    125 mm
  • Depth with alternative assembly
    39 mm
  • Efficiency
    typ. 92.2 % (24 V DC)
  • Maximum altitude
    ≤ 5000 m (> 2000 m, observe derating)
  • Overvoltage category EN 62477-1
    III
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • DNV GL noise radiation
    Class B
  • Electromagnetic HF field
    EN 61000-4-3
  • Frequency range
    50 Hz ... 60 Hz
  • Signal
    2 kV (Test Level 3 - asymmetrical)
  • Frequency
    0 Hz
  • Test level 2
    150 Hz 1.5 kHz (Test Level 3)
  • Test level 6
    0 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3)
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • REACh SVHC
    Lead 7439-92-1
  • ETIM 6.0
    EC002046
  • Mains buffering
    typ. 14 ms (24 V DC)
  • Insulation voltage input/output
    4 kV DC (type test)
  • Type test (IEC/EN 60950-1) C
    0.5 kV DC
  • Stripping length
    8 mm
  • Flexible conductor cross section flexible (ferrule, w/o plastic sleeve)
    0.2 mm² ... 1.5 mm²
  • Setting range of the output voltage (USet)
    24 V DC ... 29.5 V DC (> 24 V DC, constant capacity)
  • Short-circuit-proof
    yes
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Types of signaling
    LED
  • Connection labeling
    3.4 +
  • Maximum contact load
    24 V DC
  • MTBF (IEC 61709, SN 29500)
    > 1600000 h (25 °C)
  • Time
    520000 h
  • Protection class
    Special with SELV input and output
  • Side element version
    Aluminum
  • Height with alternative assembly
    130 mm
  • Digital
    0 V DC
  • Inrush current limitation typical
    1 A
  • Type test (IEC/EN 60950-1) B
    4 kV DC
  • Production test A
    2 kV DC
  • Conductor cross section solid
    0.2 mm² ... 1 mm²
  • Conductor cross section AWG
    24 ... 16
  • Static Boost (IStat.Boost)
    6.25 A
  • No-load proof
    yes
  • Connection in series
    yes
  • UOut
    > 0.9 x USet (LED lights up green)
  • Switch contact
    floating
  • Temperature
    30 °C
  • Hood version
    Stainless steel X6Cr17
  • Width with alternative assembly
    122 mm
  • Power loss nominal load max.
    < 10 W
  • Climatic class
    3K3 (EN 60721)
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standards/regulations
    EN 61000-4-29
  • Additional text
    Test Level 2
  • Electrostatic discharge
    EN 61000-4-2
  • Output
    1 kV (Test Level 3 - symmetrical)
  • I/O/S
    asymmetrical
  • Voltage dip
    0 %
  • Damped oscillating magnetic field
    EN 61000-4-10
  • Input, output (test level 1)
    100 kHz 1 MHz (Test Level 2 - symmetrical)
  • Attenuated oscillating wave
    EN 61000-4-18
  • ECLASS 11.0
    27210901
  • Flexible conductor cross section (ferrule with plastic sleeve)
    0.2 mm² ... 0.75 mm²
  • Nominal output current (IN)
    5 A
  • System deviation, static
    < 1 % (change in load, static 10 % ... 90 %)
  • Residual ripple
    < 10 mVPP
  • Protection against overvoltage at the output (OVP)
    ≤ 32 V DC
  • Analog
    4 mA ... 20 mA ±5 % (Load ≤400 Ω)
  • Function
    Signal ground
  • Auxiliary converter stage
    190 kHz ... 220 kHz (Auxiliary converter stage)
  • Degree of protection
    IP20
  • Width
    36 mm
  • Power dissipation SLEEP MODE
    < 1 W
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Vibration (operation)
    5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)
  • Overvoltage category EN 61010-1
    II
  • Designation
    Shipbuilding
  • Identification
    ABS
  • Contact discharge
    8 kV (Test Level 4)
  • Comments
    Criterion A
  • Surge voltage load (surge)
    EN 61000-4-5
  • Asymmetrical conducted disturbance variables
    EN 61000-4-16
  • Test level 4
    15 kHz 150 kHz (Test Level 3)
  • Test level 3
    1.5 kHz 15 kHz (Test Level 3)
  • Input, output (test level 3)
    10 MHz (Test Level 2 - asymmetrical)
  • ECLASS 10.0.1
    27210901
  • Maximum power dissipation in no-load condition
    < 2 W
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Shock
    18 ms, 30g, in each space direction (according to IEC 60068-2-27)
  • Degree of pollution
    2
  • Standard designation
    Mains variation/undervoltage
  • Conducted noise emission
    EN 55016
  • Noise emission
    EN 55016
  • Discharge in air
    15 kV (Test Level 4)
  • Input
    1 kV (Test Level 3 - symmetrical)
  • Conducted interference
    EN 61000-4-6
  • Voltage dips
    EN 61000-4-29
  • Test level 1
    15 Hz 150 Hz (Test Level 3)
  • Alternating component of DC voltage
    EN 61000-4-17
  • Signals (test level 2)
    100 kHz 1 MHz (Test Level 2 - asymmetrical)
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • ECLASS 9.0
    27210901
  • Ambient temperature (start-up type tested)
    -40 °C
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • EMC requirements for noise emission
    EN 61000-6-3
  • EMC requirements, power plant
    IEC 61850-3
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • DNV GL conducted interference
    Class B
  • Test field strength
    100 A/m
  • Fast transients (burst)
    EN 61000-4-4
  • Power frequency magnetic field
    EN 61000-4-8
  • Pulse-shape magnetic field
    EN 61000-4-9
  • Test level 5
    16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
  • Input, output (test level 2)
    100 kHz 1 MHz (Test Level 2 - asymmetrical)
  • Criterion A
    Normal operating behavior within the specified limits.
  • Signals (test level 1)
    100 kHz 1 MHz (Test Level 2 - symmetrical)
  • ETIM 7.0
    EC002046

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$249.10

Stock:

3

Select Qty:

$249.10

$249.10 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo