1046611 Phoenix Contact Terminal Blocks

Phoenix Contact 1046611 Distribution block, bridged internally, The blocks can be bridged with one another via the conductor shaft. For corresponding plug-in bridges, see accessories, nom. voltage: 450 V, nominal current: 17.5 A, connection method: Push-in connection, number of
Phoenix Contact

Part#:1046611

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 323

Dec 22, 2024

Distribution block, bridged internally, The blocks can be bridged with one another via the conductor shaft. For corresponding plug-in bridges, see accessories, nom. voltage: 450 V, nominal current: 17.5 A, connection method: Push-in connection, number of

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1046611 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Number of levels
    1
  • Flammability rating according to UL 94
    V0
  • Maximum power dissipation for nominal condition
    0.56 W
  • Finger protection
    guaranteed
  • Nominal cross section
    1.5 mm²
  • Overvoltage category
    III
  • Maximum total current
    26 A
  • Back of the hand protection
    guaranteed
  • Surge voltage test setpoint
    7.3 kV
  • Result of flexion and pull-out test
    Test passed
  • Conductor cross section tensile test
    2.5 mm²
  • Result of temperature-rise test
    Test passed
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Acceleration
    30g
  • Number of shocks per direction
    3
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Stripping length
    8 mm ... 10 mm
  • Conductor cross section flexible max.
    1.5 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    1.5 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Potentials
    1
  • Insulating material group
    I
  • Degree of pollution
    3
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Result of power-frequency withstand voltage test
    Test passed
  • Result of surge voltage test
    Test passed
  • Bending test turns
    135
  • Setpoint
    1 N
  • Result of aging test
    Test passed
  • Result of thermal test
    Test passed
  • Test duration per axis
    5 h
  • Shock duration
    18 ms
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Connection in acc. with standard
    IEC 60998-2-2
  • Conductor cross section AWG max.
    14
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.34 mm²
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 11.0
    27141120
  • ETIM 4.0
    EC000897
  • UNSPSC 6.01
    30211811
  • UNSPSC 18.0
    39121410
  • Note
    Notes on operation The blocks can be bridged with one another via the conductor shaft. For corresponding plug-in bridges, see accessories
  • Color
    red
  • Rated surge voltage
    6 kV
  • Nominal voltage UN
    450 V
  • Open side panel
    No
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Tensile test result
    Test passed
  • Tractive force setpoint
    50 N
  • Conductor cross section short circuit testing
    2.5 mm²
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Static insulating material application in cold
    -60 °C
  • Number of connections
    4
  • Insulating material
    PA
  • Nominal current IN
    17.5 A
  • Maximum load current
    22 A
  • Bending test rotation speed
    10 rpm
  • Tight fit on carrier
    NS 35/NS 15
  • Result of tight fit on support
    Test passed
  • Short circuit stability result
    Test passed
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2018-05
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Shock form
    Half-sine
  • Shock test result
    Test passed
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Connection method
    Push-in connection
  • Height
    17.7 mm
  • Conductor cross section flexible min.
    0.14 mm²
  • Max. AWG conductor cross section, flexible
    12
  • Internal cylindrical gage
    A1 / B1
  • ECLASS 10.0.1
    27141120
  • ECLASS 4.1
    27141121
  • ECLASS 7.0
    27141120
  • ETIM 6.0
    EC000897
  • UNSPSC 19.0
    39121410
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 5.1
    27141120
  • ETIM 3.0
    EC000897
  • UNSPSC 12.01
    39121410
  • UNSPSC 13.2
    39121410
  • UNSPSC 21.0
    39121410
  • Connection cross sections directly pluggable
    0.34 mm² 2.5 mm² 26 14
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 4.0
    27141121
  • ECLASS 9.0
    27141120
  • ETIM 7.0
    EC000897
  • UNSPSC 11
    39121410
  • ECLASS 6.0
    27141100
  • UNSPSC 7.0901
    39121410
  • UNSPSC 20.0
    39121410
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Result of voltage-drop test
    Test passed
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Length
    21.6 mm
  • Conductor cross section solid max.
    2.5 mm²
  • Oscillation, broadband noise test result
    Test passed
  • ASD level
    6.12 (m/s2)2/Hz
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Min. AWG conductor cross section, flexible
    24
  • Bending test conductor cross section/weight
    0.14 mm² / 0.2 kg
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2018-05
  • Width
    8.3 mm
  • Conductor cross section solid min.
    0.34 mm²
  • Conductor cross section AWG min.
    26
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.34 mm²
  • ECLASS 5.0
    27141120
  • Short-time current
    0.3 kA
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    1.5 mm²

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$1.58

Stock:

323

Select Qty:

$1.58

$1.58 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo