1104890 Phoenix Contact Electrical Safety Devices
Part#:1104890
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 64
Dec 22, 2024
Safe extension module with 8 safe inputs and 4 safe outputs, 4 reset inputs or 4 signal outputs, 4 clock outputs, TBUS interface, up to SILCL 3, Cat. 4/PL e, SIL 3, pluggable screw terminal block, TBUS connector included
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1104890 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Width 22.61 mm
- Current consumption typ. 12 mA (typically with US)
- Protective circuit Serial protection against polarity reversal
- Input current range "0" signal < 1 mA
- Output name O1, O2, O3, O4
- Nominal output voltage range 18.5 V DC ... 28.1 V DC (US - 0,7 V)
- Ambient temperature (operation) -10 °C ... 55 °C (observe derating)
- Designation Air clearances and creepage distances between the power circuits
- Power consumption at US typ. 1.08 W (Outputs inactive)
- Number of inputs 4
- Input voltage range "0" signal 0 V DC ... 5 V DC
- Cable length max. 100 m (per output)
- Limiting continuous current 100 mA (per channel)
- Max. inductive load max. 2.4 mH
- Test pulses ≤ 200 µs (Test pulse duration)
- Nominal voltage range 18.2 V DC ... 27.8 V DC (US - 1 V)
- Degree of protection IP20
- Assembly instructions Observe derating
- Status display 1 x LED (green), 2 x LED (orange)
- Torque 0.5 Nm ... 0.6 Nm
- Rated insulation voltage 250 V AC
- Degree of pollution 2
- Conformance CE-compliant
- Depth 113.6 mm
- Maximum altitude ≤ 2000 m (Above sea level)
- Filter time 250 ms ±2 ms (Test pulse rate > 500 ms)
- Description of the input configurable (as signal output or reset input)
- Input voltage range "1" signal 11 V DC ... 28.8 V DC
- Number of outputs 4
- Output voltage when switched off max. 0.1 V
- Max. capacitive load max. 470 nF
- Discharging circuit Yes, internal
- Response time see user manual
- Net weight 159 g
- Protection class III (EN 50178)
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Conductor cross-section AWG 24 ... 12
- Performance level (PL) e (2-channel wiring)
- Overvoltage category II
- ECLASS 10.0.1 27371819
- Height 112.58 mm
- Ambient temperature (storage/transport) -20 °C ... 85 °C
- Rated control circuit supply voltage US 24 V DC -20 % / +20 % (external fuse, typically 4 A)
- Rated control supply current IS typ. 45 mA (Outputs inactive)
- Protective circuit/component Suppressor diode
- Output description PNP, IEC 61131-2 Typ 0,1
- Switching frequency max. 1/4 x tCycle [Hz]
- Error detection time at 1-channel structure < 3.5 s (OFF state)
- Voltage 24 V DC (via A1)
- Mounting position vertical or horizontal
- Min. degree of protection of inst. location IP54
- Housing material Polyamide PA non-reinforced
- pluggable Yes
- Screw thread M3
- Stop category 0
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- ECLASS 11.0 27371819
- Max. permissible relative humidity (operation) 95 % (non-condensing)
- Max. permissible humidity (storage/transport) 95 % (non-condensing)
- Inrush current max. 600 mA (Δt < 10 ms)
- Input name Reset inputs
- Max. permissible overall conductor resistance 1.2 kΩ (Input and reset circuit at US)
- Nominal output voltage 24 V DC (Supply via A1)
- Leakage current max. 100 µA
- Ohmic load min. 50 Ω (Observe limiting continuous current)
- Maximum inrush current 1.1 A (Δt = 3 s at Us)
- Restart time min. 5 s (Boot time)
- Mounting type DIN rail mounting
- Operating voltage display 1 x green LED
- Connection method Screw connection
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Safety Integrity Level (SIL) 2
- Rated surge voltage/insulation Basic insulation 4 kV between 24 V power supply and I/Os to the housing
- Shock 10g for Δt = 16 ms (continuous shock, 1000 shocks in each space direction)
- ECLASS 9.0 27371819
- Short-circuit protection Yes (self-limitation at 1.1 A)
- Output voltage range 18.2 V DC ... 27.8 V DC (US - 1 V)
- Cycle time see user manual
- Nominal operating mode 100% operating factor
- Housing color yellow
- Indication 2 x LED (red)
- Stripping length 7 mm
- Safety Integrity Level Claim Limit (SIL CL) 3 (2-channel wiring)
- Standards/regulations EN 50178
- Vibration (operation) 10 Hz ... 150 Hz, 2g
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$552.29
Stock:
64
Select Qty:
$552.29
$552.29 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.