Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

2774017 Phoenix Contact Terminal Blocks

Phoenix Contact 2774017 Double-level terminal block, connection method: Screw connection, cross section: 0.2 mm² - 4 mm², AWG: 24 - 12, width: 6.2 mm, color: gray, mounting type: NS 35/7,5, NS 35/15, NS 32
Phoenix Contact

Part#:2774017

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 6573

Dec 23, 2024

Double-level terminal block, connection method: Screw connection, cross section: 0.2 mm² - 4 mm², AWG: 24 - 12, width: 6.2 mm, color: gray, mounting type: NS 35/7,5, NS 35/15, NS 32

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2774017 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • UNSPSC 12.01
    39121410
  • Number of levels
    2
  • Insulating material group
    I
  • Open side panel
    Yes
  • Back of the hand protection
    guaranteed
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Bending test conductor cross section/weight
    0.2 mm² / 0.2 kg
  • Result of tight fit on support
    Test passed
  • Result of thermal test
    Test passed
  • Relative insulation material temperature index (Elec.; UL 746 B)
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Width
    6.2 mm
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.25 mm²
  • Insulating material
    PA
  • Overvoltage category
    III
  • Maximum load current
    32 A (with 4 mm² conductor cross section)
  • Result of surge voltage test
    Test passed
  • Checking the mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Bending test turns
    135
  • Setpoint
    1 N
  • Requirements, voltage drop
    ≤ 3.2 mV
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Height NS 35/7,5
    62 mm
  • Conductor cross section flexible max.
    4 mm²
  • Conductor cross section AWG max.
    12
  • Cross section with insertion bridge, stranded max.
    2.5 mm²
  • 2 conductors with same cross section, stranded max.
    1.5 mm²
  • 2 conductors with same cross section, stranded min.
    0.2 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Nominal cross section
    4 mm²
  • Flammability rating according to UL 94
    V0
  • Connection in acc. with standard
    CSA
  • Nominal current IN
    32 A
  • Shock protection test specification
    IEC 60529:2001-02
  • Result of power-frequency withstand voltage test
    Test passed
  • Conductor cross section tensile test
    4 mm²
  • Short circuit stability result
    Test passed
  • Short-time current
    0.48 kA
  • Static insulating material application in cold
    -60 °C
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Length
    56 mm
  • Height NS 32
    67 mm
  • Connection method
    Screw connection
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.25 mm²
  • 2 conductors with same cross section, solid min.
    0.2 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    1.5 mm²
  • Stripping length
    8 mm
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 11.0
    27141120
  • ECLASS 4.0
    27141100
  • ETIM 6.0
    EC000897
  • Rated surge voltage
    6 kV
  • Nominal voltage UN
    500 V
  • Surge voltage test setpoint
    7.3 kV
  • Result of flexion and pull-out test
    Test passed
  • Tensile test result
    Test passed
  • Tight fit on carrier
    NS 32/NS 35
  • Conductor cross section short circuit testing
    4 mm²
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • End cover width
    2.5 mm
  • Conductor cross section solid max.
    4 mm²
  • Conductor cross section AWG min.
    24
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    2.5 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    1.5 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 9.0
    27141120
  • ETIM 2.0
    EC000897
  • UNSPSC 13.2
    39121410
  • Number of connections
    4
  • Color
    gray
  • Maximum power dissipation for nominal condition
    1.02 W (the value is multiplied when connecting multiple levels)
  • Degree of pollution
    3
  • Finger protection
    guaranteed
  • Bending test rotation speed
    10 rpm
  • Tractive force setpoint
    60 N
  • Result of temperature-rise test
    Test passed
  • Result of voltage-drop test
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Height NS 35/15
    69.5 mm
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    4 mm²
  • 2 conductors with same cross section, solid max.
    1.5 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Screw thread
    M3
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 5.0
    27141100
  • ECLASS 6.0
    27141100
  • UNSPSC 7.0901
    39121410
  • UNSPSC 18.0
    39121410
  • Cross section with insertion bridge, solid max.
    4 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    0.25 mm²
  • Tightening torque max
    0.8 Nm
  • Tightening torque, min
    0.6 Nm
  • ECLASS 10.0.1
    27141120
  • ECLASS 5.1
    27141100
  • ETIM 3.0
    EC000897
  • ETIM 7.0
    EC000897
  • UNSPSC 19.0
    39121410
  • UNSPSC 21.0
    39121410
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.1
    27141100
  • ECLASS 7.0
    27141120
  • ETIM 4.0
    EC000897
  • UNSPSC 11
    39121410
  • UNSPSC 6.01
    30211811
  • UNSPSC 20.0
    39121410

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$9.02

Stock:

6,573

Select Qty:

$9.02

$9.02 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo