2903145 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2903145 Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: single phase, output: 24 V DC/10 A
Phoenix Contact

Part#:2903145

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: single phase, output: 24 V DC/10 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2903145 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Height
    130 mm
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Installation height
    ≤ 5000 m (> 2000 m, observe derating)
  • AC frequency range
    50 Hz ... 60 Hz ±5 Hz
  • Recommended breaker for input protection
    6 A ... 16 A (Characteristics B, C, D, K)
  • Protective circuit/component
    Varistor
  • Setting range of the output voltage (USet)
    24 V DC ... 28 V DC (constant capacity)
  • Derating
    > 60 °C ... 70 °C (2.5%/K)
  • Feedback voltage resistance
    ≤ 35 V DC
  • Net weight
    1 kg
  • Conductor cross section solid max.
    1.5 mm²
  • Stripping length
    8 mm
  • Standard – Safety extra-low voltage
    IEC 60950-1 (SELV) and EN 60204-1 (PELV)
  • Mains variation/undervoltage
    Semi F47-0706
  • Electrostatic discharge
    EN 61000-4-2
  • Frequency range
    0.15 MHz ... 80 MHz
  • Voltage
    10 V (Test Level 3)
  • ECLASS 10.0.1
    27040701
  • ECLASS 4.0
    27040700
  • ECLASS 9.0
    27040701
  • ETIM 7.0
    EC002540
  • UNSPSC 11
    39121004
  • UNSPSC 21.0
    39121004
  • Depth
    160 mm
  • Degree of protection
    IP20
  • Ambient temperature (start-up type tested)
    -40 °C
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Dielectric strength maximum
    300 V AC 15 s
  • Frequency range (fN)
    50 Hz ... 60 Hz ±10 %
  • Mains buffering time
    typ. 20 ms (120 V AC)
  • Type of protection
    Transient surge protection
  • Dynamic Boost (IDyn.Boost)
    15 A (5 s)
  • Protection against overvoltage at the output (OVP)
    ≤ 30 V DC
  • Residual ripple
    < 20 mVPP (with nominal values)
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Connection method
    Push-in connection
  • Standard - Safety of transformers
    EN 61558-2-16 (air clearances and creepage distances only)
  • Standard - Safe isolation
    DIN VDE 0100-410
  • UL approvals
    UL Listed UL 508
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Output
    1 kV (Test Level 2 - symmetrical)
  • Width
    42 mm
  • Installation distance right/left
    0 mm / 0 mm
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Nominal input voltage range
    100 V AC ... 240 V AC
  • Current consumption
    3.1 A (100 V AC)
  • Nominal power consumption
    285 VA
  • Input fuse
    6.3 A (internal (device protection))
  • Nominal output current (IN)
    10 A
  • Connection in series
    yes
  • Output power
    240 W
  • Maximum power dissipation in no-load condition
    < 5.1 W
  • Efficiency
    typ. 90 % (120 V AC)
  • Assembly instructions
    alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
  • Conductor cross section flexible min.
    0.2 mm²
  • EMC requirements for noise emission
    EN 61000-6-3
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Shipbuilding approval
    DNV GL (EMC B)
  • Discharge in air
    8 kV (Test Level 4)
  • Test field strength
    10 V/m (Test Level 3)
  • Conducted interference
    EN 61000-4-6
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.1
    27040700
  • ECLASS 7.0
    27049002
  • ETIM 4.0
    EC000599
  • UNSPSC 12.01
    39121004
  • Typical response time
    < 1 s
  • Insulation voltage input/output
    3 kV AC (type test)
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section AWG min.
    24
  • Conductor cross section AWG max.
    16
  • Standard - Electrical safety
    IEC 60950-1/VDE 0805 (SELV)
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Electromagnetic HF field
    EN 61000-4-3
  • Fast transients (burst)
    EN 61000-4-4
  • Input
    2 kV (Test Level 3 - symmetrical)
  • ECLASS 5.0
    27049000
  • ETIM 3.0
    EC001039
  • UNSPSC 7.0901
    39121004
  • UNSPSC 13.2
    39121004
  • Installation distance top/bottom
    50 mm / 50 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Degree of pollution
    2
  • Input voltage range
    100 V AC ... 240 V AC -15 % ... +10 %
  • Discharge current to PE
    < 3.5 mA
  • Inrush current
    typ. 20 A
  • Power factor (cos phi)
    0.93
  • Nominal output voltage
    24 V DC ±1 %
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
  • Power loss nominal load max.
    < 25 W
  • MTBF (IEC 61709, SN 29500)
    > 1800000 h (25 °C)
  • Protection class
    I (in closed control cabinet)
  • Conductor cross section flexible max.
    1.5 mm²
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
  • Rail applications
    EN 50121-4
  • Contact discharge
    6 kV (Test Level 4)
  • Comments
    Criterion A
  • Signal
    1 kV (Test Level 2 - asymmetrical)
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 11.0
    27040701
  • ECLASS 5.1
    27049000
  • ETIM 6.0
    EC002540
  • UNSPSC 19.0
    39121004
  • Surge voltage load (surge)
    EN 61000-4-5
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 6.0
    27049000
  • UNSPSC 6.01
    30211502
  • UNSPSC 18.0
    39121004
  • UNSPSC 20.0
    39121004

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo