2903145 Phoenix Contact AC/DC Power Supplies
Part#:2903145
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: single phase, output: 24 V DC/10 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2903145 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height 130 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Installation height ≤ 5000 m (> 2000 m, observe derating)
- AC frequency range 50 Hz ... 60 Hz ±5 Hz
- Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K)
- Protective circuit/component Varistor
- Setting range of the output voltage (USet) 24 V DC ... 28 V DC (constant capacity)
- Derating > 60 °C ... 70 °C (2.5%/K)
- Feedback voltage resistance ≤ 35 V DC
- Net weight 1 kg
- Conductor cross section solid max. 1.5 mm²
- Stripping length 8 mm
- Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)
- Mains variation/undervoltage Semi F47-0706
- Electrostatic discharge EN 61000-4-2
- Frequency range 0.15 MHz ... 80 MHz
- Voltage 10 V (Test Level 3)
- ECLASS 10.0.1 27040701
- ECLASS 4.0 27040700
- ECLASS 9.0 27040701
- ETIM 7.0 EC002540
- UNSPSC 11 39121004
- UNSPSC 21.0 39121004
- Depth 160 mm
- Degree of protection IP20
- Ambient temperature (start-up type tested) -40 °C
- Climatic class 3K3 (in acc. with EN 60721)
- Dielectric strength maximum 300 V AC 15 s
- Frequency range (fN) 50 Hz ... 60 Hz ±10 %
- Mains buffering time typ. 20 ms (120 V AC)
- Type of protection Transient surge protection
- Dynamic Boost (IDyn.Boost) 15 A (5 s)
- Protection against overvoltage at the output (OVP) ≤ 30 V DC
- Residual ripple < 20 mVPP (with nominal values)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Connection method Push-in connection
- Standard - Safety of transformers EN 61558-2-16 (air clearances and creepage distances only)
- Standard - Safe isolation DIN VDE 0100-410
- UL approvals UL Listed UL 508
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Output 1 kV (Test Level 2 - symmetrical)
- Width 42 mm
- Installation distance right/left 0 mm / 0 mm
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Nominal input voltage range 100 V AC ... 240 V AC
- Current consumption 3.1 A (100 V AC)
- Nominal power consumption 285 VA
- Input fuse 6.3 A (internal (device protection))
- Nominal output current (IN) 10 A
- Connection in series yes
- Output power 240 W
- Maximum power dissipation in no-load condition < 5.1 W
- Efficiency typ. 90 % (120 V AC)
- Assembly instructions alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
- Conductor cross section flexible min. 0.2 mm²
- EMC requirements for noise emission EN 61000-6-3
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Shipbuilding approval DNV GL (EMC B)
- Discharge in air 8 kV (Test Level 4)
- Test field strength 10 V/m (Test Level 3)
- Conducted interference EN 61000-4-6
- REACh SVHC Lead 7439-92-1
- ECLASS 4.1 27040700
- ECLASS 7.0 27049002
- ETIM 4.0 EC000599
- UNSPSC 12.01 39121004
- Typical response time < 1 s
- Insulation voltage input/output 3 kV AC (type test)
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section AWG min. 24
- Conductor cross section AWG max. 16
- Standard - Electrical safety IEC 60950-1/VDE 0805 (SELV)
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Electromagnetic HF field EN 61000-4-3
- Fast transients (burst) EN 61000-4-4
- Input 2 kV (Test Level 3 - symmetrical)
- ECLASS 5.0 27049000
- ETIM 3.0 EC001039
- UNSPSC 7.0901 39121004
- UNSPSC 13.2 39121004
- Installation distance top/bottom 50 mm / 50 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Degree of pollution 2
- Input voltage range 100 V AC ... 240 V AC -15 % ... +10 %
- Discharge current to PE < 3.5 mA
- Inrush current typ. 20 A
- Power factor (cos phi) 0.93
- Nominal output voltage 24 V DC ±1 %
- Connection in parallel Yes, for redundancy and increased capacity
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Power loss nominal load max. < 25 W
- MTBF (IEC 61709, SN 29500) > 1800000 h (25 °C)
- Protection class I (in closed control cabinet)
- Conductor cross section flexible max. 1.5 mm²
- EMC requirements for noise immunity EN 61000-6-1
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Rail applications EN 50121-4
- Contact discharge 6 kV (Test Level 4)
- Comments Criterion A
- Signal 1 kV (Test Level 2 - asymmetrical)
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 11.0 27040701
- ECLASS 5.1 27049000
- ETIM 6.0 EC002540
- UNSPSC 19.0 39121004
- Surge voltage load (surge) EN 61000-4-5
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 6.0 27049000
- UNSPSC 6.01 30211502
- UNSPSC 18.0 39121004
- UNSPSC 20.0 39121004
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨