Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: 1-phase, output: 24 V DC/3 A C2LPS
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2903147 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Installation height ≤ 5000 m (> 2000 m, observe derating)
- Discharge current to PE < 0.25 mA
- Input fuse 6.3 A (internal (device protection))
- Nominal output voltage 24 V DC ±1 %
- Feedback voltage resistance ≤ 35 V DC
- Output power 72 W
- Insulation voltage input/output 3 kV AC (type test)
- Assembly instructions alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
- Conductor cross section flexible max. 1.5 mm²
- Stripping length 8 mm
- Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)
- Electrostatic discharge EN 61000-4-2
- Fast transients (burst) EN 61000-4-4
- Criterion A Normal operating behavior within the specified limits.
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 5.0 27049000
- ETIM 4.0 EC002540
- UNSPSC 20.0 39121004
- Height 130 mm
- Installation distance top/bottom 50 mm / 50 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Degree of pollution 2
- AC frequency range 50 Hz ... 60 Hz ±10 %
- Mains buffering time typ. 10 ms (120 V AC)
- Protective circuit/component Varistor
- Setting range of the output voltage (USet) 24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
- Derating > 60 °C ... 70 °C (2.5%/K)
- Residual ripple < 50 mVPP (with nominal values)
- Net weight 0.35 kg
- Protection class II (in closed control cabinet)
- Depth 115 mm
- Degree of protection IP20
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Climatic class 3K3 (in acc. with EN 60721)
- Nominal power consumption 157.7 VA
- Type of protection Transient surge protection
- Nominal output current (IN) 3 A
- Width 30 mm
- Ambient temperature (start-up type tested) -25 °C
- Input voltage range 100 V AC ... 240 V AC -15 % ... +10 %
- Current consumption 1.4 A (100 V AC)
- Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K)
- Dynamic Boost (IDyn.Boost) 4.5 A (1 s)
- Connection in parallel Yes, for redundancy and increased capacity
- Maximum power dissipation in no-load condition < 1 W
- Typical response time < 1 s
- Connection method Push-in connection
- Conductor cross section AWG min. 24
- Standard - Safety of transformers EN 61558-2-16 (air clearances and creepage distances only)
- Rail applications EN 50121-4
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Electromagnetic HF field EN 61000-4-3
- Frequency range 0.15 MHz ... 80 MHz
- Conducted interference EN 61000-4-6
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 4.1 27040700
- ECLASS 7.0 27049002
- UNSPSC 13.2 39121004
- Installation distance right/left 0 mm / 0 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Nominal input voltage range 100 V AC ... 240 V AC
- Dielectric strength maximum ≤ 300 V AC 15 s
- Inrush current ≤ 15 A (typical)
- Power factor (cos phi) 0.52
- Connection in series yes
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Efficiency > 89 % (for 230 V AC and nominal values)
- Mounting position horizontal DIN rail NS 35, EN 60715
- EMC requirements for noise emission EN 61000-6-3
- Standard - Electrical safety IEC 60950-1/VDE 0805 (SELV)
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Comments Criterion A
- Signal 1 kV (Test Level 2 - asymmetrical)
- Voltage 10 V (Test Level 3)
- ECLASS 5.1 27049000
- ETIM 7.0 EC002540
- UNSPSC 18.0 39121004
- Protection against overvoltage at the output (OVP) ≤ 30 V DC
- Power loss nominal load max. < 10 W
- MTBF (IEC 61709, SN 29500) > 3500000 h (25 °C)
- Conductor cross section solid max. 1.5 mm²
- EMC requirements for noise immunity EN 61000-6-1
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Contact discharge 6 kV (Test Level 4)
- Test field strength 10 V/m (Test Level 3)
- Input 3 kV (Test Level 3 - symmetrical)
- Surge voltage load (surge) EN 61000-4-5
- REACh SVHC Lead 7439-92-1
- ECLASS 4.0 27040700
- ECLASS 6.0 27049000
- ETIM 6.0 EC002540
- UNSPSC 19.0 39121004
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section AWG max. 16
- Standard - Safe isolation DIN VDE 0100-410
- UL approvals UL Listed UL 508
- Discharge in air 8 kV (Test Level 4)
- Output 1 kV (Test Level 2 - symmetrical)
- ECLASS 10.0.1 27040701
- ECLASS 11.0 27040701
- ECLASS 9.0 27040701
- UNSPSC 21.0 39121004
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$90.54
Stock:
304
Select Qty:
$90.54
$90.54 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨