Potential collective terminal, In the end application, the applicable safety regulations for overload and short-circuit protection on the connected conductors must be considered., nom. voltage: 1000 V, nominal current: 101 A, connection method: Screw conn
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3002371 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Result of thermal test Test passed
- Shock test result Test passed
- Shock form Half-sine
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Conductor cross section flexible max. 10 mm²
- 2 conductors with same cross section, solid min. 1.5 mm²
- Open side panel No
- Result of power-frequency withstand voltage test Test passed
- Bending test turns 135
- Tractive force setpoint 190 N
- Result of temperature-rise test Test passed
- Short-time current 4.2 kA
- 2 conductors with same cross section, solid max. 16 mm²
- 2 conductors with same cross section, stranded max. 10 mm²
- ECLASS 10.0.1 27141120
- Permissible humidity (storage/transport) 30 % ... 70 %
- ECLASS 5.1 27141111
- ETIM 3.0 EC000897
- UNSPSC 7.0901 39121410
- Conductor cross section short circuit testing 35 mm²
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Number of shocks per direction 3
- Surface flammability NFPA 130 (ASTM E 162) passed
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Width 19.4 mm
- Tightening torque, min 3.2 Nm
- Degree of pollution 2
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Tensile test result Test passed
- Min. AWG conductor cross section, flexible 20
- Conductor cross section flexible min. 0.5 mm²
- 2 conductors with same cross section, stranded min. 1.5 mm²
- Two conductors with the same cross section, AWG stranded, max. 8
- Internal cylindrical gage B9
- Ambient temperature (actuation) -5 °C ... 70 °C
- Tight fit on carrier NS 35
- Requirements, voltage drop ≤ 1.6 mV
- Short circuit stability result Test passed
- Test frequency f1 = 5 Hz to f2 = 250 Hz
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Connection method Push-in connection
- Maximum load current 57 A
- Result of surge voltage test Test passed
- Bending test conductor cross section/weight 2.5 mm² / 0.7 kg
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Conductor cross section AWG min. 20
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.5 mm²
- Two conductors with the same cross section, AWG solid max. 6
- ECLASS 5.0 27141127
- Result of voltage-drop test Test passed
- Ageing test for screwless modular terminal block temperature cycles 192
- Test spectrum Service life test category 2, bogie-mounted
- Maximum power dissipation for nominal condition 4.06 W (the value is multiplied when connecting multiple levels)
- Finger protection guaranteed
- Power frequency withstand voltage setpoint 2.2 kV
- Conductor cross section tensile test 35 mm²
- Result of tight fit on support Test passed
- Acceleration 30g
- Shock duration 18 ms
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Height NS 35/15 57.8 mm
- Conductor cross section AWG max. 6
- Conductor cross section solid min. 0.5 mm²
- ECLASS 4.0 27141127
- Conductor cross section solid max. 16 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve max. 10 mm²
- Surge voltage test setpoint 9.8 kV
- Bending test rotation speed 10 rpm
- Setpoint 5 N
- Result of aging test Test passed
- Oscillation, broadband noise test result Test passed
- Test duration per axis 5 h
- Static insulating material application in cold -60 °C
- Two conductors with the same cross section, AWG solid min. 16
- Nominal current IN 57 A
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Height NS 35/7,5 50.3 mm
- Tightening torque max 3.7 Nm
- Connection cross sections directly pluggable 1 mm² 16 mm² 16 6 4 mm² 10 mm²
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 4.1 27141127
- ECLASS 6.0 27141100
- UNSPSC 6.01 30211812
- Connection in acc. with standard IEC 60947-7-1
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03
- Note In the end application, the applicable safety regulations for overload and short-circuit protection on the connected conductors must be considered.
- Insulating material group I
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
- Conductor cross section flexible, with ferrule with plastic sleeve max. 10 mm²
- Nominal cross section 16 mm²
- Rated surge voltage 8 kV
- Nominal voltage UN 1000 V
- Result of flexion and pull-out test Test passed
- Number of levels 1
- Overvoltage category III
- Length 79.9 mm
- Flammability rating according to UL 94 V0
- ASD level 6.12 (m/s2)2/Hz
- Stripping length 18 mm
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.5 mm²
- Screw thread M6
- Max. AWG conductor cross section, flexible 8
- Two conductors with the same cross section, AWG stranded, min. 16
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ECLASS 7.0 27141120
- ETIM 6.0 EC000897
- Back of the hand protection guaranteed
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 10 mm²
- ECLASS 9.0 27141120
- ETIM 7.0 EC000897
- UNSPSC 11 39121411
- Insulating material PA
- UNSPSC 19.0 39121410
- Color gray
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 1.5 mm²
- UNSPSC 12.01 39121411
- Number of connections 5
- ECLASS 11.0 27141120
- ETIM 4.0 EC000897
- UNSPSC 20.0 39121410
- UNSPSC 21.0 39121410
- UNSPSC 13.2 39121411
- UNSPSC 18.0 39121410
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$20.70
Stock:
648
Select Qty:
$20.70
$20.70 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨