3044199 Phoenix Contact Terminal Blocks
Part#:3044199
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 183
Dec 22, 2024
Feed-through terminal block, nom. voltage: 1000 V, nominal current: 76 A, connection method: Screw connection, number of connections: 2, cross section: 1.5 mm² - 25 mm², AWG: 16 - 4, width: 12.2 mm, height: 54.4 mm, color: gray, mounting type: NS 35/7,5,
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3044199 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 10 mm²
- ECLASS 4.0 27141100
- ECLASS 9.0 27141120
- ECLASS 5.1 27141100
- Permissible humidity (storage/transport) 30 % ... 70 %
- ECLASS 7.0 27141120
- Internal cylindrical gage A7
- ECLASS 6.0 27141100
- ETIM 2.0 EC000897
- Potentials 1
- Area of application Railway industry
- Nominal current IN 76 A
- Back of the hand protection guaranteed
- Result of flexion and pull-out test Test passed
- Bending test turns 135
- Bending test conductor cross section/weight 1.5 mm² / 0.4 kg
- Result of voltage-drop test Test passed
- Short-time current 1.92 kA
- Number of levels 1
- Insulating material PA
- Maximum load current 101 A (with 25 mm² conductor cross section)
- Open side panel Yes
- Surge voltage test setpoint 9.8 kV
- Bending test rotation speed 10 rpm
- Tight fit on carrier NS 32/NS 35
- Shock protection test specification IEC 60529:2001-02
- Finger protection guaranteed
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Nominal cross section 16 mm²
- Overvoltage category III
- Maximum power dissipation for nominal condition 2.43 W
- Ambient temperature (assembly) -5 °C ... 70 °C
- Number of connections 2
- Flammability rating according to UL 94 V0
- Degree of pollution 3
- Result of surge voltage test Test passed
- Power frequency withstand voltage setpoint 2.2 kV
- Conductor cross section tensile test 25 mm²
- Result of tight fit on support Test passed
- Conductor cross section short circuit testing 16 mm²
- Test frequency f1 = 5 Hz to f2 = 250 Hz
- Shock duration 18 ms
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Length 55.5 mm
- Tightening torque max 3 Nm
- Conductor cross section flexible max. 25 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve max. 16 mm²
- Result of temperature-rise test Test passed
- Color gray
- Rated surge voltage 8 kV
- Insulating material group I
- Nominal voltage UN 1000 V
- Result of power-frequency withstand voltage test Test passed
- Tensile test result Test passed
- Setpoint 5 N
- Requirement temperature-rise test Increase in temperature ≤ 45 K
- Test spectrum Service life test category 2, bogie-mounted
- Test duration per axis 5 h
- Acceleration 30g
- Note Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area.
- Conductor cross section flexible min. 1.5 mm²
- ECLASS 10.0.1 27141120
- Number of shocks per direction 3
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Width 12.2 mm
- Height NS 35/7,5 55 mm
- Height NS 35/15 62.5 mm
- Short circuit stability result Test passed
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2018-05
- Shock form Half-sine
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- End cover width 2.2 mm
- Screw thread M5
- Stripping length 14 mm
- Conductor cross section AWG min. 16
- Conductor cross section flexible, with ferrule without plastic sleeve max. 16 mm²
- Conductor cross section solid max. 25 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.75 mm²
- 2 conductors with same cross section, stranded max. 6 mm²
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ECLASS 4.1 27141100
- Conductor cross section flexible, with ferrule without plastic sleeve min. 1 mm²
- ECLASS 5.0 27141100
- ETIM 3.0 EC000897
- Result of thermal test Test passed
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Height 54.4 mm
- Tightening torque, min 2.5 Nm
- Connection in acc. with standard CSA
- Conductor cross section flexible, with ferrule with plastic sleeve min. 1 mm²
- 2 conductors with same cross section, solid min. 1 mm²
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- UNSPSC 7.0901 39121410
- UNSPSC 19.0 39121410
- ASD level 6.12 (m/s2)2/Hz
- Surface flammability NFPA 130 (ASTM E 162) passed
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
- Static insulating material application in cold -60 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Connection method Screw connection
- Conductor cross section solid min. 1.5 mm²
- Conductor cross section AWG max. 4
- ECLASS 11.0 27141120
- ETIM 7.0 EC000897
- UNSPSC 18.0 39121410
- Tractive force setpoint 135 N
- Min. AWG conductor cross section, flexible 16
- 2 conductors with same cross section, solid max. 6 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 6 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 1 mm²
- ETIM 6.0 EC000897
- UNSPSC 13.2 39121410
- UNSPSC 20.0 39121410
- Requirements, voltage drop U1 ≤ 3,2 mVU2 ≤ 1,5 x U1dT ≤ 45 K
- Max. AWG conductor cross section, flexible 4
- Ambient temperature (actuation) -5 °C ... 70 °C
- UNSPSC 12.01 39121410
- UNSPSC 6.01 30211811
- Proof of thermal characteristics (needle flame) effective duration 30 s
- 2 conductors with same cross section, stranded min. 1 mm²
- ETIM 4.0 EC000897
- UNSPSC 11 39121410
- UNSPSC 21.0 39121410
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$3.42
Stock:
183
Select Qty:
$3.42
$3.42 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨