3046032 Phoenix Contact Terminal Blocks
Part#:3046032
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 10065
Dec 23, 2024
Fuse modular terminal block, fuse type: Glass / ceramics / ..., connection method: Screw connection, cross section: 0.14 mm²- 6 mm², AWG: 26 - 10, nominal current: 6.3 A, nom. voltage: 500 V, width: 6.2 mm, fuse type: G / 5 x 20, mounting type: NS 35/7,5,
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3046032 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Insulating material group I
- Finger protection guaranteed
- Result of tight fit on support Test passed
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Oscillation, broadband noise test result Test passed
- Testing the rated value of the power dissipation (overload and short circuit Protection) Test passed
- Shock form Semi-sinusoidal
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Length 57.8 mm
- Conductor cross section solid max. 6 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.14 mm²
- Flammability rating according to UL 94 V0
- Fuse type Glass / ceramics / ...
- Contact resistance Test passed
- Bending test turns 135
- Test spectrum Service life test category 1, class B, body mounted
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Number of shocks per direction 3
- Surface flammability NFPA 130 (ASTM E 162) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Height NS 35/7,5 73 mm
- Conductor cross section AWG max. 10
- 2 conductors with same cross section, solid min. 0.14 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 1.5 mm²
- Stripping length 9 mm
- Screw thread M3
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 4.0 27141100
- ECLASS 11.0 27141116
- ECLASS 9.0 27141116
- ETIM 6.0 EC000899
- UNSPSC 6.01 30211811
- UNSPSC 18.0 39121410
- UNSPSC 21.0 39121410
- Rated operating voltage 250 V
- Back of the hand protection guaranteed
- Result of power-frequency withstand voltage test Test passed
- Result of flexion and pull-out test Test passed
- Actuatiing forces on plug in or lever in fuse insert carriers Test passed
- Result of thermal test Test passed
- ASD level 1.857 (m/s2)2/Hz
- Shock test result Test passed
- Shock duration 30 ms
- Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
- Width 6.2 mm
- Conductor cross section flexible min. 0.14 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve max. 4 mm²
- 2 conductors with same cross section, stranded max. 1.5 mm²
- Open side panel No
- Surge voltage test setpoint 4.8 kV
- Compatibitity between modular fuse terminal block and fuse insert Test passed
- Testing the rated value of the power dissipation (exclusively short circuit protection) Test passed
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03
- Acceleration 5g
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
- Static insulating material application in cold -60 °C
- Conductor cross section solid min. 0.14 mm²
- Conductor cross section AWG min. 26
- 2 conductors with same cross section, solid max. 1.5 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
- Internal cylindrical gage A4
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- ECLASS 10.0.1 27141116
- ECLASS 4.1 27141100
- ETIM 2.0 EC000897
- ECLASS 7.0 27141116
- UNSPSC 7.0901 39121410
- UNSPSC 19.0 39121410
- Fuse G / 5 x 20
- Nominal current IN 6.3 A
- Note Swing the locking lever to its final position before replacing the fuse.
- Bending test rotation speed 10 rpm
- Test frequency f1 = 5 Hz to f2 = 150 Hz
- Test duration per axis 5 h
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Height NS 35/15 80.5 mm
- Conductor cross section flexible max. 6 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.14 mm²
- 2 conductors with same cross section, stranded min. 0.14 mm²
- Connection method Screw connection
- Permissible humidity (storage/transport) 30 % ... 70 %
- Tightening torque max 0.8 Nm
- Ambient temperature (actuation) -5 °C ... 70 °C
- ECLASS 5.1 27141100
- ETIM 3.0 EC000899
- ETIM 4.0 EC000899
- UNSPSC 11 39121410
- UNSPSC 20.0 39121410
- Tightening torque, min 0.6 Nm
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 5.0 27141100
- ECLASS 6.0 27141100
- ETIM 7.0 EC000899
- UNSPSC 12.01 39121410
- UNSPSC 13.2 39121410
- Color black
- Degree of pollution 3
- Rated surge voltage 6 kV
- Maximum load current 6.3 A (the current is determined by the fuse used)
- Bending test conductor cross section/weight 0.14 mm² / 0.2 kg
- Result of temperature-rise test Test passed
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 0.14 mm²
- Nominal cross section 4 mm²
- Maximum power dissipation for nominal condition 1.6 W
- Connection in acc. with standard CSA
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Conductor cross section flexible, with ferrule with plastic sleeve max. 4 mm²
- Number of connections 2
- Overvoltage category III
- Maximum power dissipation max. 1.6 W (with single arrangement of the fuse terminal block in the event of overload)
- Result of surge voltage test Test passed
- Nominal voltage UN 500 V (The voltage is determined by the fuse or selected LED display)
- Power frequency withstand voltage setpoint 1.5 kV
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 2.5 mm²
- Number of levels 1
- Insulating material PA
- Area of application Railway industry
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$7.78
Stock:
10,065
Select Qty:
$7.78
$7.78 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨