Filters
Manufacturer
More in this category
Compressed Air Preparation Units
part#
description
manufacturer
GAL20006T
AirTAC GAL20006T - GAL Series Lubricator, Recommand lubricant ISO VG32 or equivalent, PC bowl, 1/8"NPT, With bracket
AirTAC
STOCK: 144
Fast shippingGAFC20006AST
AirTAC GAFC20006AST - GAFC Series F&R.L. 2-piece combination, Adjustable pressure 20psi~130psi, PC bowl, 1/8"NPT, 40 micron, Auto Drain N.O., With Gauge, Without reflux valve
AirTAC
STOCK: 144
Fast shippingBFR20002T
AirTAC BFR20002T - Filter regulator, BFR Series, NPT
AirTAC
STOCK: 137
Fast shippingGAR20008SNT
AirTAC GAR20008SNT - GAFR Series Regulator, Adjustable pressure 20psi~130psi, , 1/4"NPT, Without Gauge, Without reflux valve, With bracket
AirTAC
STOCK: 136
Fast shippingGAFC30008AST
AirTAC GAFC30008AST - GAFC Series F&R.L. 2-piece combination, Adjustable pressure 20psi~130psi, PC bowl, 1/4"NPT, 40 micron, Auto Drain N.O., With Gauge, Without reflux valve
AirTAC
STOCK: 136
Fast shippingGAL40015T
AirTAC GAL40015T - GAL Series Lubricator, Recommand lubricant ISO VG32 or equivalent, PC bowl, 1/2"NPT, With bracket
AirTAC
STOCK: 128
Fast shippingGAR30008SJNTK
AirTAC GAR30008SJNTK - GAFR Series Regulator, Adjustable pressure 20psi~130psi, , 1/4"NPT, Without Gauge, With reflux valve reflux valve, Without bracket
AirTAC
STOCK: 128
Fast shippingGAC30008ST
AirTAC GAC30008ST - GAC Series F.R.L. 3-piece combination, Adjustable pressure 20psi~130psi, PC bowl, 1/4"NPT, 40 micron, Semi-auto Drain, With Gauge, Without reflux valve
AirTAC
STOCK: 128
Fast shippingGAF40015T
AirTAC GAF40015T - GAF Series Filter, PC bowl, 1/2"NPT, 40 micron, Semi-auto Drain, With bracket
AirTAC
STOCK: 128
Fast shippingGPF20008MT
AirTAC GPF20008MT - GPF Series Coalescing Filter&Regulator, PC bowl, 1/4"NPT, 0.3 micron., Semi-auto Drain, With bracket
AirTAC
STOCK: 122
Fast shippingGAFC20008AST
AirTAC GAFC20008AST - GAFC Series F&R.L. 2-piece combination, Adjustable pressure 20psi~130psi, PC bowl, 1/4"NPT, 40 micron, Auto Drain N.O., With Gauge, Without reflux valve
AirTAC
STOCK: 125
Fast shippingSDR100M52
AirTAC SDR100M52 - Regulator SDR100-M5-2, SDR Series
AirTAC
STOCK: 120
Fast shippingGPF30008ADT
AirTAC GPF30008ADT - GPF Series Coalescing Filter&Regulator, PC bowl, 1/4"NPT, 0.01 micron, Auto Drain N.O., With bracket
AirTAC
STOCK: 118
Fast shippingGAFR30008ST
AirTAC GAFR30008ST - GAFR Series Filter&Regulator, Adjustable pressure 20psi~130psi, PC bowl, 1/4"NPT, 40 micron, Semi-auto Drain, With Gauge, Without reflux valve, With bracket
AirTAC
STOCK: 119
Fast shippingGPF20008ADT
AirTAC GPF20008ADT - GPF Series Coalescing Filter&Regulator, PC bowl, 1/4"NPT, 0.01 micron, Auto Drain N.O., With bracket
AirTAC
STOCK: 117
Fast shippingGAC40010ST
AirTAC GAC40010ST - GAC Series F.R.L. 3-piece combination, Adjustable pressure 20psi~130psi, PC bowl, 3/8"NPT, 40 micron, Semi-auto Drain, With Gauge, Without reflux valve
AirTAC
STOCK: 114
Fast shippingGAFC20008ST
AirTAC GAFC20008ST - GAFC Series F&R.L. 2-piece combination, Adjustable pressure 20psi~130psi, PC bowl, 1/4"NPT, 40 micron, Semi-auto Drain, With Gauge, Without reflux valve
AirTAC
STOCK: 118
Fast shippingGAL400C15T
AirTAC GAL400C15T - GAL Series Lubricator, Recommand lubricant ISO VG32 or equivalent, Metal bowl, 1/2"NPT, With bracket
AirTAC
STOCK: 114
Fast shippingGPF20006ADT
AirTAC GPF20006ADT - GPF Series Coalescing Filter&Regulator, PC bowl, 1/8"NPT, 0.01 micron, Auto Drain N.O., With bracket
AirTAC
STOCK: 112
Fast shippingGTF20008T
AirTAC GTF20008T - GTF Series Filter, Adjustable pressure 20psi~130psi, PC bowl, 1/4"NPT, 40 micron, Semi-auto Drain, With bracket
AirTAC
STOCK: 112
Fast shipping
Items per page:
Compressed Air Preparation Units
General Guide & Overview
Compressed air is a widely used form of energy in various industries, powering pneumatic systems and equipment. However, the air leaving the compressor is often not suitable for direct use due to impurities and incorrect pressure levels. That's where air preparation units, also known as FRL units (Filter, Regulator, Lubricator), play a crucial role.
Air preparation units are designed to condition the compressed air, ensuring optimal performance and efficiency. The FRL unit consists of three separate units that carry out different phases of conditioning: filtration, regulation, and lubrication.
Filtration is the first step, where contaminants such as dust, water, and oil are removed from the compressed air. This ensures that downstream equipment remains protected and operates at its best. Regulation is the second phase, controlling the pressure of the compressed air in the system to match the requirements of the application. Lastly, lubrication introduces controlled amounts of oil into the flow of compressed air, reducing friction and increasing the lifespan of air-driven equipment.
Proper selection of the filter size, pressure rating, port size, and lubricator type is essential to meet the specific requirements of each application. By investing in high-quality compressed air preparation units, you can ensure the longevity of your pneumatic equipment and optimize its performance.
So, whether you are in manufacturing, automotive, or any other industry that relies on compressed air, understanding the importance of air preparation units is vital for efficient and reliable operation.
Importance of Air Preparation in Pneumatic Systems
Air preparation plays a vital role in pneumatic systems, ensuring the cleanliness, pressure, and lubrication of compressed air. In order to maintain optimal performance and reliability, it is crucial to address the presence of contaminants such as particles, water, and oil that can impair the operation of pneumatic components. Proper filtration is necessary to remove dirt, dust, and other particles from the compressed air and minimize the risk of damage to downstream equipment.
Moisture and oil, which can negatively impact the performance of pneumatic systems, are effectively eliminated through the use of coalescing filters. The level of air purity required will vary depending on the specific application, and different industry segments may have additional requirements to ensure the proper functioning of their equipment. Therefore, it is essential to select and implement the appropriate air preparation measures.
In addition to addressing contaminants, the flow rate of compressed air must be adequate to achieve the desired cylinder piston travel speeds. Furthermore, the operating pressure of the system needs to be carefully matched to the requirements of the application for optimal performance. By paying attention to these factors and implementing proper air preparation techniques, businesses can improve the process reliability, machine availability, and service life of their pneumatic components.
Tips for Designing and Specifying Air Preparation Systems
When designing or specifying air preparation subsystems, engineers need to consider several key factors to ensure optimal performance and minimize maintenance costs. One crucial aspect is properly matching the port sizes and operating pressure ranges of pneumatic components. This ensures efficient operation and prevents issues such as pressure drops or excessive pressure that can lead to equipment damage or downtime.
Another important consideration is the inclusion of disconnect components, such as manual shut-off relief valves and isolation/lockout valves. These components provide a means to isolate downstream equipment from the compressed air source, allowing for safe maintenance procedures and preventing inadvertent re-energization. This not only enhances safety but also reduces the risk of equipment breakdown and associated maintenance costs.
Air filtration is a critical aspect of air preparation systems, as it eliminates contaminants that could affect the performance and lifespan of pneumatic equipment. Various passive filters, such as centrifugal and coalescing filters, effectively remove particles, water, and oil from the compressed air, ensuring clean and reliable operation. Additionally, implementing appropriate drain systems, such as manual, semi-automatic, or automatic drains, helps to remove accumulated moisture from the filter bowl, further enhancing the efficiency and longevity of the system.
Finally, maintaining proper downstream air pressure is of utmost importance. This can be achieved through the installation of air pressure regulators. These regulators ensure that the compressed air delivered to the equipment operates at the correct pressure, preventing potential damage or inefficiencies caused by excessive or insufficient pressure. By following these tips and incorporating the right components, engineers can design and specify air preparation systems that optimize the performance and longevity of pneumatic equipment, ultimately reducing maintenance costs and downtime.
FAQ
What is an air preparation unit?
An air preparation unit, also known as an FRL unit (Filter, Regulator, Lubricator), is used to condition compressed air by removing contaminants, regulating pressure, and introducing controlled amounts of oil for lubrication.
Why is air preparation important in pneumatic systems?
Air preparation is essential in pneumatic systems to ensure the correct air cleanliness, pressure, and lubrication. Contaminants can impair the operation of components and reduce system reliability.
What does filtration do in an air preparation unit?
Filtration in an air preparation unit removes contaminants such as dust, water, and oil from the compressed air, ensuring cleaner air for downstream equipment.
How does regulation work in an air preparation unit?
Regulation in an air preparation unit controls the pressure of the compressed air in the system, allowing for precise pressure adjustments based on the requirements of the application.
Why is lubrication necessary in an air preparation unit?
Lubrication in an air preparation unit introduces controlled amounts of oil into the compressed air flow, reducing friction and increasing the lifespan of air-driven equipment.
What factors should I consider when designing or specifying air preparation subsystems?
When designing or specifying air preparation subsystems, consider proper port sizes and operating pressure ranges, disconnect components for isolation and lockout, air filtration for removing contaminants, drain systems for moisture removal, and air pressure regulators for maintaining proper downstream pressure.