METSECT5DA040
Schneider Electric METSECT5DA040 is a current transformer designed for busbar mounting with a sealing function. It operates within an ambient air temperature range of -25 to +60°C. This transformer accommodates a maximum bar cross-section of 32x65mm and is engineered to transform a primary current of 400 A into a secondary current of 5 A.
Schneider Electric
Quick Quote
METSECT5CC008
Schneider Electric METSECT5CC008 is a current transformer designed for DIN rail mounting and features sealing functionality. It operates within an ambient air temperature range of -25 to +60°C. This transformer is part of the sub-range dedicated to current transformation, with a primary current rating of 75 A and a secondary current rating of 5 A. It accommodates a maximum cable outer diameter of 21 mm.
Schneider Electric
Quick Quote
METSECT5DE125
Schneider Electric METSECT5DE125 is a current transformer designed for busbar mounting with a sealing function. It operates within an ambient air temperature range of -25 to +60°C. This transformer accommodates a maximum bar cross-section of 54x102mm and is engineered to transform a primary current of 1250 A to a secondary current of 5 A.
Schneider Electric
Quick Quote
METSECT5DA060
Schneider Electric METSECT5DA060 is a current transformer designed for busbar mounting with a sealing function. It operates within an ambient air temperature range of -25 to +60°C. This part falls under the sub-range category of Current Transformer and accommodates a maximum cross-section of 32x65mm for bars. It is engineered to handle a primary current of 600 A and transforms it into a secondary current of 5 A.
Schneider Electric
Quick Quote
METSECT5DE100
Schneider Electric METSECT5DE100 is a current transformer designed for busbar mounting with a sealing function. It operates within an ambient air temperature range of -25 to +60°C. This transformer accommodates a maximum bar cross-section of 54x102mm and is engineered to transform a primary current of 1000 A into a secondary current of 5 A.
Schneider Electric
Quick Quote
METSECT5DA050
Schneider Electric METSECT5DA050 is a current transformer designed for busbar mounting with a sealing function. It operates within an ambient air temperature range of -25 to +60°C. This transformer is part of the sub-range named Current Transformer and accommodates a maximum bar cross-section of 32x65mm. It is designed to transform a primary current of 500 A into a secondary current of 5 A.
Schneider Electric
Quick Quote
METSECT5DB300
Schneider Electric METSECT5DB300 is a current transformer designed for busbar mounting with a sealing function. It operates within an ambient air temperature range of -25 to +60°C. This transformer is part of the sub-range named Current Transformer and accommodates a maximum bar cross-section of 38x27mm. It is designed to transform a primary current of 3000 A into a secondary current of 5 A.
Schneider Electric
Quick Quote
METSECT5DC200
Schneider Electric METSECT5DC200 is a current transformer designed for busbar mounting and features sealing functionality. It operates within an ambient air temperature range of -25 to +60°C. This part falls under the sub-range name of Current Transformer and accommodates a maximum cross-section of 52x27mm for bars. It is designed to transform a primary current of 2000 A into a secondary current of 5 A.
Schneider Electric
Quick Quote
METSECT5CC013
Schneider Electric METSECT5CC013 is a current transformer designed for DIN rail mounting and features sealing capabilities. It operates within an ambient air temperature range of -25 to +60°C. This component falls under the sub-range category of Current Transformers, with a primary current specification of 125 A and a secondary current of 5 A. It accommodates a maximum cable outer diameter of 21 mm.
Schneider Electric
Quick Quote
METSECT5MD080
Schneider Electric METSECT5MD080 is a current transformer designed for DIN rail Busbar mounting without sealing. It operates within an ambient air temperature range of -25 to +60°C. This transformer accommodates bars with a maximum cross-section of 12x50mm or 20x40mm and cables with a maximum outer diameter of 40mm. It is designed to transform a primary current of 800 A into a secondary current of 5 A.
Schneider Electric
Quick Quote
METSECT5DC300
Schneider Electric METSECT5DC300 is a current transformer designed for busbar mounting and features sealing functionality. It operates within an ambient air temperature range of -25 to +60°C. This component is part of the Current Transformer sub-range and accommodates a maximum bar cross-section of 52x27mm. It is designed to transform a primary current of 3000 A into a secondary current of 5 A.
Schneider Electric
Quick Quote
METSECT5DB125
Schneider Electric METSECT5DB125 is a current transformer designed for busbar mounting with a sealing function. It operates within an ambient air temperature range of -25 to +60°C. This transformer accommodates a maximum bar cross-section of 38x27mm and is engineered to transform a primary current of 1250 A into a secondary current of 5 A.
Schneider Electric
Quick Quote
METSECT5MC050
Schneider Electric METSECT5MC050 is a current transformer designed for DIN rail Busbar mounting without sealing. It operates within an ambient air temperature range of -25 to +60°C. This transformer is part of the sub-range dedicated to current transformation, accommodating bars with maximum cross-sections of 10x40mm, 20x32mm, and 25x25mm. It is engineered to handle a primary current of 500 A and transforms it into a secondary current of 5 A. The maximum cable outer diameter that can be used with this transformer is 32 mm.
Schneider Electric
Quick Quote
METSECT5MC025
Schneider Electric METSECT5MC025 is a current transformer designed for DIN rail Busbar mounting without sealing. It operates within an ambient air temperature range of -25 to +60°C. This transformer accommodates bars with maximum cross sections of 10x40mm, 20x32mm, and 25x25mm. It is specified with a primary current of 250 A and a secondary current of 5 A. The maximum cable outer diameter that can be used with this transformer is 32 mm.
Schneider Electric
Quick Quote
METSECT5DH125
Schneider Electric METSECT5DH125 is a current transformer designed for busbar mounting without sealing. It operates within an ambient air temperature range of -25 to +60°C. This transformer accommodates bars with a maximum cross-section of 38x102mm. It is designed to transform a primary current of 1250 A into a secondary current of 5 A.
Schneider Electric
Quick Quote
METSECT5MA020
Schneider Electric METSECT5MA020 is a current transformer designed for DIN rail Busbar mounting without sealing. It operates within an ambient air temperature range of -25 to +60°C. This transformer accommodates bars with a maximum cross-section of 10x32mm or 15x25mm and cables with a maximum outer diameter of 27mm. It is designed to transform a primary current of 200 A into a secondary current of 5 A.
Schneider Electric
Quick Quote
METSECT5MA040
Schneider Electric METSECT5MA040 is a current transformer designed for DIN rail Busbar mounting without sealing. It operates within an ambient air temperature range of -25 to +60°C. This transformer accommodates bars with a maximum cross-section of 10x32mm or 15x25mm and cables with a maximum outer diameter of 27mm. It is designed to transform a primary current of 400 A into a secondary current of 5 A.
Schneider Electric
Quick Quote
METSECT5VV600
Schneider Electric METSECT5VV600 is a current transformer designed for busbar mounting. It operates within an ambient air temperature range of -25 to +60°C. This component is part of the current transformer sub-range and is specified with a primary current of 6000 A and a secondary current of 5 A.
Schneider Electric
Quick Quote