A9R21440
Schneider Electric A9R21440 is a Residual Current Circuit Breaker (RCCB) within the iID sub-range, designed for DIN rail mounting. This 4-pole device features a rated impulse voltage (Uimp) of 6 kV, a rated current of 40A, and a residual current sensitivity of 30mA / 0.03A. It has a mechanical durability of 20,000 operations at no load and an electrical durability of 15,000 operations with load. The RCCB has dimensions of 91 mm in height, 73.5 mm in depth, and 72 mm in width. It is rated for an insulation voltage (Ui) of 500 V, an operating voltage (Ue) of 415 V, and a phase-to-phase rated voltage (AC) of 415 V, with all 4 poles protected.
Schneider Electric
STOCK: 1
Fast shippingA9V51225
Schneider Electric A9V51225 is an earth leakage add-on block designed for use with miniature circuit breakers (M.C.B.) within the Vigi iC60 sub-range. This product features a rated current of 25A and is suitable for DIN rail mounting. It is a 2-pole device with dimensions of 91 mm in height, 73.5 mm in depth, and 63 mm in width. The A9V51225 operates at a rated voltage of 230 V AC phase-to-neutral and 415 V AC phase-to-phase, with a residual current sensitivity of 30mA or 0.03A. It is designed to protect 2 poles.
Schneider Electric
Quick Quote
A9N18556
Schneider Electric A9N18556 is an earth leakage add-on block designed for use with miniature circuit breakers (M.C.B.) within the Vigi C120 sub-range. This product features a rated current of 125A and is suitable for DIN rail mounting. It is a 2-pole device with dimensions of 95 mm in height, 73 mm in depth, and 117 mm in width. The A9N18556 operates at a rated voltage of 230 V AC phase-to-neutral and 415 V AC phase-to-phase, with a residual current sensitivity of 300mA or 0.3A. It is designed to protect 2 poles.
Schneider Electric
Quick Quote
A9V41225
Schneider Electric A9V41225 is an earth leakage add-on block designed for use with miniature circuit breakers, part of the Vigi iC60 sub-range. This product features a rated current of 25A and is suitable for DIN rail mounting. It is a 2-pole device with dimensions of 91 mm in height, 73.5 mm in depth, and 63 mm in width. The A9V41225 operates at a rated voltage of 230 V AC phase-to-neutral and 415 V AC phase-to-phase, with a residual current sensitivity of 30mA or 0.03A, covering 2 protected poles.
Schneider Electric
Quick Quote
A9N18598
Schneider Electric A9N18598 is an earth leakage add-on block designed for use with miniature circuit breakers (M.C.B.) within the Vigi C120 sub-range. This product features a rated current of 125A and is suitable for DIN rail mounting. It is a 4-pole device, with dimensions of 95 mm in height, 73 mm in depth, and 198 mm in width. The A9N18598 operates at a rated voltage of 230 V AC phase-to-neutral and 415 V AC phase-to-phase, with a residual current sensitivity of 300mA or 0.3A. All four poles are protected, ensuring comprehensive coverage for earth leakage detection and interruption.
Schneider Electric
Quick Quote
A9R12263
Schneider Electric A9R12263 is a Residual Current Circuit Breaker (RCCB) within the iID sub-range, designed for DIN rail mounting. This 2-pole RCCB features a rated impulse voltage (Uimp) of 6 kV, a rated current of 63A, and a residual current sensitivity of 100mA / 0.1A. It has a mechanical durability of 20,000 operations at no load and an electrical durability of 15,000 operations with load. The device measures 91 mm in height, 73.5 mm in depth, and 36 mm in width. It is rated for an insulation voltage (Ui) of 500 V, an operating voltage (Ue) of 240 V, and a phase-to-neutral rated voltage (AC) of 240 V, ensuring protection for 2 poles.
Schneider Electric
Quick Quote
A9V02763
Schneider Electric A9V02763 is an earth leakage add-on block designed for use with miniature circuit breakers (M.C.B.) within the Vigi iC60 sub-range. This product features a rated current of 63A and is suitable for DIN rail mounting. It is a 4-pole device, indicating it can connect to and protect four circuits simultaneously. The A9V02763 operates at a rated voltage of 240 V from phase-to-neutral and 415 V from phase-to-phase. It offers residual current sensitivity of 30mA or 0.03A, ensuring protection against earth leakage across all four protected poles.
Schneider Electric
Quick Quote
56225
Schneider Electric RH10P is a flush-mounted automation part designed for remote reset and test functions. It features instantaneous protection settings at 0.3A and includes digital outputs with a Fault contact configured as SPDT (Single Pole Double Throw) and a Voltage-presence contact as SPST (Single Pole Single Throw). The supply voltage requirement is AC 50/60Hz at 110-130 V. This part is equipped with earth-leakage protection functions, operates with a minimum current of 0.01 A at 12V minimum load, and has a residual current sensitivity of 0.3 A. The output voltage is rated at 4 VA DC.
Schneider Electric
Quick Quote
56272
Schneider Electric 56272
Schneider Electric
Quick Quote
56220
Schneider Electric 56220
Schneider Electric
Quick Quote
56200
Schneider Electric 56200
Schneider Electric
Quick Quote
A9N18591
Schneider Electric A9N18591 is an earth leakage add-on block designed for use with miniature circuit breakers (M.C.B.) within the Vigi C120 sub-range. This product features a rated current of 125A and is suitable for DIN rail mounting. It is a 2-pole device with dimensions of 95 mm in height, 73 mm in depth, and 117 mm in width. The A9N18591 operates at a rated voltage of 230 V AC phase-to-neutral and 415 V AC phase-to-phase, with a residual current sensitivity of 30mA or 0.03A. It is designed to protect 2 poles.
Schneider Electric
Quick Quote
A9N18558
Schneider Electric A9N18558 is an earth leakage add-on block designed for use with miniature circuit breakers (M.C.B.) within the Vigi C120 sub-range. This product features a rated current of 125A and is suitable for DIN rail mounting. It is a 3 Pole device, with dimensions of 95 mm in height, 73 mm in depth, and 171 mm in width. The A9N18558 operates at a rated voltage of 230 V AC phase-to-neutral and 415 V AC phase-to-phase, with a residual current sensitivity of 300mA or 0.3A. It is designed to protect 3 poles.
Schneider Electric
Quick Quote
A9D73632
Schneider Electric A9D73632 is a Residual Current Circuit Breaker with Overload protection (RCBO) / Earth Leakage Circuit Breaker (ELCB) from the iSPN sub-range. It features a rated current of 32A and is designed for DIN rail mounting. This 2 Pole device has a net height of 93 mm, a depth of 70 mm, and a width of 18 mm. It operates at a rated voltage (AC) of 230V phase-to-neutral, with a residual current sensitivity of 30mA / 0.03A. The protected pole count is 1 Pole, and it offers a mechanical durability of 20,000 operations at no load and an electrical durability of 10,000 operations with load. The tripping curve is classified as C.
Schneider Electric
Quick Quote
A9N21691
Schneider Electric A9N21691 is an earth leakage add-on block designed for use with M.C.B., part of the iDPN Vigi modules Clario sub-range. This product features a rated current of 40A and is capable of 20,000 mechanical operations at no load and 10,000 electrical operations with load. It is designed for DIN rail mounting and has dimensions of 81 mm in height, 69 mm in depth, and 18 mm in width. The A9N21691 operates with 2 poles, both of which are protected, and has a rated voltage (AC) phase-to-neutral of 230 V. Its residual current sensitivity is set at 30mA / 0.03A.
Schneider Electric
Quick Quote
A9V41425
Schneider Electric A9V41425 is an earth leakage add-on block designed for use with miniature circuit breakers, part of the Vigi iC60 sub-range. This product features a rated current of 25A and is suitable for DIN rail mounting. It is a 4-pole device, with dimensions of 91 mm in height, 73.5 mm in depth, and 54 mm in width. The A9V41425 operates at a rated voltage of 230 V AC phase-to-neutral and 415 V AC phase-to-phase, with a residual current sensitivity of 30mA or 0.03A. All four poles are protected.
Schneider Electric
Quick Quote
A9V41463
Schneider Electric A9V41463 is an earth leakage add-on block designed for use with miniature circuit breakers, part of the Vigi iC60 sub-range. This product features a rated current of 63A and is suitable for DIN rail mounting. It is a 4-pole device, with dimensions of 91 mm in height, 73.5 mm in depth, and 135 mm in width. The A9V41463 operates at a rated voltage of 230 V AC phase-to-neutral and 415 V AC phase-to-phase, with a residual current sensitivity of 30mA / 0.03A. All four poles are protected.
Schneider Electric
Quick Quote
M9D11640
Schneider Electric M9D11640 is a Residual Current Circuit Breaker with Overload protection (RCBO) / Earth Leakage Circuit Breaker (ELCB) from the N40 Vigi sub-range. This 2-pole device is designed for DIN rail mounting and features a rated current of 40A. It has a residual current sensitivity of 30mA / 0.03A and operates at a rated voltage (AC) of 240V phase-to-neutral. The M9D11640 protects 1 pole and is characterized by a C tripping curve.
Schneider Electric
Quick Quote
M9D14616
Schneider Electric M9D14616 is a Residual Current Circuit Breaker with Overload protection (RCBO) / Earth Leakage Circuit Breaker (ELCB) from the N40 Vigi sub-range. This 2-pole device has a rated current of 16A and is designed for DIN rail mounting. It features a residual current sensitivity of 300mA / 0.3A and operates at a rated voltage (AC) of 240V phase-to-neutral. The device protects 1 pole and utilizes a C tripping curve.
Schneider Electric
Quick Quote
2CSF202201R3630
ABB 2CSF202201R3630 is a Residual Current Circuit Breaker (RCCB) designed with screw-clamp connections and a rated current of 63A. It features a type A design and is suitable for DIN rail mounting. This RCCB has a rated insulation voltage (Ui) of 69 mm and a rated impulse voltage (Uimp) of 35 mm. The device is structured to accommodate 2-poles (2P) with a net width of 85 mm. It operates with a control voltage of 300mA and is designed for a supply voltage of 400 V. The RCCB is capable of 10,000 operations and supports 20,000 operations for its analog outputs. It also includes a number of Normally Closed (NC) circuits.
ABB Control
Quick Quote
Items per page: