Filters
Manufacturer
Manual Motor Protectors
part#
description
manufacturer
KTU9-40H-3D-40-VG
KTU9 Enclosed Motor Circuit Breaker, 3-Pole, Frame D High Capacity, 40 Amps, 12 x lnA Magnetic Trip, Non-metallic Type 4 / 4X / 12 , Black Off-On
Sprecher + Schuh
Quick Quote
KTU9-40H-3D-5
Sprecher + Schuh KTU9-40H-3D-5 - KTU9 Molded Case Circuit Breaker, Frame D 3-Pole High Capacity, 5 Amps, 15...20 x ln Magnetic Trip,
Sprecher + Schuh
Quick Quote
KTU9-40H-3D-6
Sprecher + Schuh KTU9-40H-3D-6 - KTU9 Molded Case Circuit Breaker, Frame D 3-Pole High Capacity, 6 Amps, 15...20 x ln Magnetic Trip,
Sprecher + Schuh
Quick Quote
KTA5-32A-16A
Sprecher + Schuh KTA5-32A-16A - KTA5 Manual Motor Controller, 10-16 Amps, 240A Magnetic Trip, 5 HP 200V / 5 HP 230V / 10 HP 460V / 15 HP 575V, Open Type, Black Off-On
Sprecher + Schuh
Quick Quote
KTA5-32A-20A
Sprecher + Schuh KTA5-32A-20A - KTA5 Manual Motor Controller, 16-20 Amps, 300A Magnetic Trip, 5 HP 200V / 7.5 HP 230V / 15 HP 460V / 20 HP 575V, Open Type, Black Off-On
Sprecher + Schuh
Quick Quote
KTA5-32A-1.6A
Sprecher + Schuh KTA5-32A-1.6A - KTA5 Manual Motor Controller, 1.0-1.6 Amps, 20A Magnetic Trip, 0.25 HP 200V / 0.33 HP 230V / 1.0 HP 460V / 1.0 HP 575V, Open Type, Black Off-On
Sprecher + Schuh
Quick Quote
KTC7-45H-32A
Sprecher + Schuh
Quick Quote
GV7RS25
Schneider Electric GV7RS25 is a Motor Protection Circuit Breaker (MPCB) within the GV7RE sub-range, designed for thermal-magnetic motor protection and manual motor starting. It features 3 poles and provides protection functions against short-circuit and thermal overload. The rated current ranges from 15 to 25 A, with a rated insulation voltage (Ui) of 750 V. This MPCB is designed for DIN rail or mounting plate installation, has a net width of 105 mm, and operates via a toggle mechanism. Protection settings for short-circuit pickup current are fixed at 25A. The rated impulse voltage (Uimp) is 8 kV, and it supports rated active power (kW) of 11 kW and 9 kW at 400/415Vac, 15 kW and 11 kW at 500Vac, and 18.5 kW and 15 kW at 690Vac. The trip current rating is 25 AT, with a frame current rating of 100 AF. It boasts mechanical durability of 50,000 operations at no load and electrical durability of 30,000 operations at 440Vac; AC-3. The GV7RS25 uses screw-clamp terminals, has a rated voltage (AC) phase-to-phase of 690 V, and protects all 3 poles. The minimum and maximum currents are 15 A and 25 A, respectively, with a trip unit type of thermal-magnetic and a utilization category of AC-3.
Schneider Electric
Quick Quote
GVAPH02
Schneider Electric GVAPH02 is a mounting accessory designed specifically for use within the GV2 sub-range. It functions as a mounting bracket, facilitating the secure installation of compatible devices.
Schneider Electric
Quick Quote
GV7AC07
Schneider Electric GV7AC07 is an adapter designed as part of the GV7 sub-range, specifically serving as a kit for combination with contactors. It is compatible with LC1F225 to LC1F265 models, facilitating their integration and operation within automation systems.
Schneider Electric
Quick Quote
GVAU026
Schneider Electric GVAU026 is a coil designed for tripping purposes within the GV2 sub-range. It functions as an undervoltage trip coil (MN) with a rated insulation voltage (Ui) of 690 V. The control voltage for AC at 60Hz is 24 Vac. This part is engineered for mechanical durability, capable of 30,000 operations when used with GV2ME/GV2P and 10,000 operations with GV3P/GV3L. It features screw-clamp type terminals for secure connections.
Schneider Electric
Quick Quote